GENERAL SAFETY INFORMATION
DESCRIPTION
UNPACKING
SUPPLIED ACCESSORIES
DIMENSIONS
WIRING DIAGRAM
SELECTOR INDICATION (FV-0511VQCL1 only)
OPERATION (FV-0511VQCL1 only)
FEATURE
INSTALLATION (NEW CONSTRUCTION)
INSTALLATION (RETROFIT)
MAINTENANCE (CLEANING)
PRACTICAL GUIDE TO INSTALLATION
SPECIFICATIONS
PRODUCT SERVICE
----------------------------------------4
-----------------------------------------4
--------------------------4
-----------------------------------------5
-----------------------------------6
---------------------------------------------7
-----------------------10
------------------10~11
-----------------------
--------------------
--------------2~3
-----------------7
-----------11
------------ 11
BACK COVER
---------6
--------8~9
FV-0511VQCL1
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing this Panasonic product.
Please read these instructions carefully before attempting to install, operate or service
the Panasonic product. Please carefully read the “GENERAL SAFETY INFORMATION”
Failure to comply with instructions could result in personal injury or property damage.
Please explain to users how to operate and maintain the product after installation,
and this booklet should be presented to users.
Please retain this booklet for future reference.
GENERAL SAFETY INFORMATION
For Your Safety
To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to
equipment or property, always observe the following safety precautions.
Explanation of symbol word panels
The following symbol word panels are used to classify and describe the level of hazard, injury, and
property damage caused when the denotation is disregarded and improper use is performed.
Denotes a potential hazard that could result in serious
WARNING
injury or death.
CAUTION
NOTICE
The following symbols are used to classify and describe the type of instructions to be observed.
This symbol is used to alert users to a specific operating procedure that must be followed
in order to operate the unit safely.
This symbol is used to alert users to a specific operating procedure that must not be
performed.
This symbol is used to alert users not to disassemble the equipment.
This symbol is used to alert users to make sure of grounding when using the equipment
with the grounding terminal.
Denotes a hazard that could result in minor injury.
Denotes a hazard that could result in property damage.
WARNING
To reduce the risk of fire, electric shock or injury to persons, observe the following :
Use this unit only in the manner intended by the manufacturer. If you have any questions,
contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
Installation work and electrical wiring must be done by qualified person(s) in accordance with
all applicable codes and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
2
Ducted fans must always be vented to the outdoors.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
These models are UL listed for tub and shower enclosures.
English
GENERAL SAFETY INFORMATION CONTINUED
Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.
Do not disassemble the unit for reconstruction. It may cause fire or electric shock.
A statement to the effect that when the product is to no longer be used, it must not be left
in place but remove, to prevent it from possibly failing.
Ceiling joist must be subjected to static load more than five times the weight of the product.
Do not install with a method which is not approved in the instructions.
Do not use this fan with any solid-state speed control device. Solid state controls may cause
harmonic distortion which can cause motor humming noise.
This product must be properly grounded.
Install the fan at least 1.5m(5feet) above the floor, and the fan must be installed above a
counter or major appliances that serves as a barrier.
CAUTION
Do not install this ventilating fan where interior room temperature may exceed 104°F (40°C)
Make sure that the electric service supply voltage is AC 120V, 60Hz.
Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and
the Occupation Safety and Health Act (OSHA).
Always disconnect the power source before working on or near the fan,motor or junction box.
Protect the supply wiring from sharp edges oil, grease, hot surfaces, chemicals or other objects.
Do not kink the supply wiring.
For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
Not for use in cooking area. (Fig.A)
The special-purpose or dedicated parts, such as mounting
fixtures, must be used if such parts are provided.
(Cooking area)
Do not install above or
inside this area
Cooking
Fig. A
45
°
Floor
5°
4
equipment
NOTICE
Provide make up air for proper ventilation.
Do not install the unit where ducts are configured as shown in below.
Adaptor
Squeezed ductSuccessive bendingExcessive bending
When one switch is connected with two or more products in parallel, the unit may not function.
Therefore, parallel connection should not be allowed.
Bend close to duct adaptor
English
3
DESCRIPTION
These products are listed by UL under UL file No. E78414.
These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is
designed to have long operating life, high dynamic response, higher speed ranges with saving energy.
The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter
flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The
lighting unit is an energy-saving LED lighting device that uses one 10W LED lamp and produces almost the
same illumination as a standard 40W incandescent lamp. Night light feature consumes around 0.1 to 0.4 W.
(FV-0511VQCL1 only)
This Panasonic ventilating fan model is equipped with a motion sensor and a humidity sensor that turn
on automatically when motion is detected, when humidity increases rapidly, or when humidity rises above
a 30% ~ 80% relative humidity set-point. It is user-adjustable to operate 0.5 ~ 60 minutes after the sensors
are no longer detected.
FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning this product on and off, the user is encouraged to try to correct the
interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect equipment into outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Warning: This equipment must be installed by qualified person in accordance with the provided installation
instructions; and all applicable codes and standards. Also, any changes or modifications not expressly
approved by the party responsible for compliance could void the user’s authority to operate this equipment.
DoC Responsible Party: Panasonic Corporation of North America
Two Riverfront Plaza, Newark, NJ 07102
Customer Call Center: 1-866-292-7299
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Risk of Fire: Type IC-Inherently Protected.
UNPACKING
Unpack and carefully remove the unit from carton.
Refer to the Supplied Accessories list to verify that all parts are present.
SUPPLIED ACCESSORIES
Part namePart nameAppearanceQuantity
Grille
Flex-Z Fast
bracket
(with 4
tapping screws
-ST4.2X20)
English
4
1
TM
1
Warranty
sheet
Installation
instructions
Self-drilling
screw
AppearanceQuantity
1
1
4
Loading...