Panasonic fv-08vre2 installation

0 (0)

INSTALLATION INSTRUCTIONS

Ventilating Fan

Model No. FV-08VRE2

CONTENTS

GENERAL SAFETY INFORMATION

2~3

DESCRIPTION

3~4

UNPACKING

4

SUPPLIED ACCESSORIES

4

DIMENSIONS

4

WIRING DIAGRAM

5

INSTALLATION

5~7

(BETWEEN JOISTS MOUNTING)

MAINTENANCE (CLEANING)

7

MAINTENANCE

 

(REPLACEMENT OF LED LAMP)

7

PRACTICAL GUIDE TO

 

INSTALLATION

BACK COVER

SPECIFICATIONS

BACK COVER

COMPATIBLE DIMMERS

 

(NOT SUPPLIED)

BACK COVER

PRODUCT SERVICE

BACK COVER

READ AND SAVE THESE INSTRUCTIONS

Thank you for purchasing this Panasonic product.

Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Failure to comply with instructions could result in personal injury or property damage.

Please explain to users how to operate and maintain the product after the installation, and this booklet should be presented to users.

Please retain this booklet for future reference.

GENERAL SAFETY INFORMATION

For your safety

To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions.

Explanation of symbol word panels

The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed.

WARNING

CAUTION

Denotes a potential hazard that could result in death or serious injury.

Denotes a hazard that could result in minor injury.

The following symbols are used to classify and describe the type of instructions to be observed.

This symbol is used to alert users to a specific operating procedure that must not be performed.

This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safety.

This symbol is used to alert users not to disassemble the equipments.

This symbol is used to alert users to make sure of grounding when using the equipment with the grounding terminal.

WARNING

To reduce the risk of fire, electric shock or injury to persons, observe the following:

Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service

disconnecting means to prevent power from being switch on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s

guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

These models are UL listed for tub and shower enclosures.

Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause motor humming noise.

Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.

Do not disassemble the unit for reconstruction. It may cause fire or electric shock.

When this product is no longer being operated, please remove the product to prevent the possibility of falling.

Ceiling joist must be subjected to static load more than five times the weight of the product.

Do not install with a method which is not approved in the instructions.

2

Panasonic fv-08vre2 installation

GENERAL SAFETY INFORMATION CONTINUED

WARNING

This product must be properly grounded.

CAUTION

Do not install this ventilating fan where interior room temperature may exceed 104 °F (40 °C).

Make sure that the electric service supply voltage is AC 120 V, 60 HZ.

Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA).

Always disconnect the power source before working on or near the fan, motor, light fixture or junction box.

Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects.

Do not kink the supply wiring.

Provide make up air for proper ventilation.

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

Do not install the unit where ducts are configured as shown in Fig A.

Not for use in cooking area. (Fig B)

The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided.

The product must use LED lamp (model:11BR30G4DIM/927/GU24) from the company Green Creative.

Please wear gloves when installing or cleaning the fan.

Prohibited Extreme

bending

Prohibited Bend

repeatedly

Duct Prohibited narrow

Adaptor

Prohibited Bend near adaptor

Fig A

(Cooking area) Do not install above

or inside this area

°

4

45

 

Cooking Floor equipment

Fig B

DESCRIPTION

This Panasonic ventilating fan model is listed by UL under UL file No. E78414. This product uses a sirocco fan driven by a capacitor motor.

The motor is designed to have an extended service life with reduced energy consumption.

It also incorporates a thermal-cut off for safety. The trim ring is a spring-loaded, quick remove type. A damper for preventing air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.

The lighting unit is an energy-saving, lighting device that uses one 11 W BR30 shape LED lamp (model: 11BR30G4DIM/927/GU24, from the company Green Creative) and produces almost the same illumination as a standard 65 W incandescent lamp.

FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning this product on and off, the user is encouraged to try to correct the interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect equipment into outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

3