Specifi cation Submittal Data / Panasonic Ventilation Fan
Description
Ventilation fan/LED light shall be low sone ceiling mount rated for continuous run. Fan shall be ENERGY
®
STAR
rated and certifi ed by the Home Ventilating Institute (HVI). Fan shall include energy effi cient LED lighting. Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards.
Motor/Blower:
• Four–pole fully enclosed condenser motor rated for continuous operation.
• Power rating shall be 120 volts and 60 Hz.
• Fan shall be UL listed for tub/shower enclosure
when used with a GFCI protected circuit and used in
insulated ceiling (TYPE I.C.).
• Motor equipped with thermal–cutoff fuse.
• Removable, permanently lubricated, plug–in motor.
Housing:
• Rust proof paint, galvanized steel body.
• Integrated dual 4" or 6” diameter duct adapter.
• Metal fl ange around recessed light aperture helps
provide an Air Barrier and assists with the decrease in leakage in the Building Envelope during blower
door testing.
• Built in backdraft damper.
• Expandable extension bracket up to 24".
• Double hanger bar system allowing for ideal
positioning.
Grille:
• Attractive design using Poly Pro
material.
• Attaches directly to housing with
torsion springs.
(1)14W GU24 base
LED lamp included.
Light:
• One 14W, ENERGY STAR rated, GU24 base LED lamp.
• LED lamp is dimmable.
• FCC Part 15 compliant.
Warranty:
• ALL Parts: 3 Years from original purchase date. LED: 5 years from original purchase date.
Architectural Specifi cations:
Ventilation fan and LED light combination shall be
ceiling mount, ENERGY STAR less than 80 CFM and no more than 0.8 sone as certifi ed by the Home Ventilating Institute (HVI) at 0.1 w.g. with no less than 66 CFM and no more than
0.7 sone at .25 w.g. Power consumption shall be no greater than 20.5 watts at 0.1 w.g. and 19.5 Watts at
0.25 w.g. ENERGY STAR less than 4 CFM/watt at 0.1 w.g. and than 3.4 CFM/ watt at 0.25 w.g. The motor shall be fully enclosed, four pole condenser type engineered to operate continuously. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4", inclusive of an integrated dual 4" or 6" duct adapter. Fan shall be
UL and cUL listed for tub/shower enclosure when
used with a GFCI protected circuit. Fan can be used to comply with ASHRAE 62.2, LEED, CalGreen*,
ENERGY STAR
WA Ventilation Code. Lamp shall be of the LED type and be no less than (1)14W, ENERGY STAR rated, GU24 base LED lamp.
* Can be used to comply with CalGreen when controlled by the Panasonic Condensation Sensor.
1 Lutron AY-600P or equal 6 Lutron S-600P or equal
2 Lutron DVELV-303P or equal 7 Lutron DV-600P or equal
3 Lutron DVLV-603P or equal 8 Lutron SLV-600P or equal
4 Lutron AYCL-153P or equal 9 Lutron S-600P or equal
5 Lutron DVCL-153P or equal 10 SmartHome 2486DWH6 or equal
®
IAP, EarthCraft, California Title-24,
Brand Model # Brand Model #
®
rated type, with no
®
rated with effi ciency of no
FV-08VRE1
4" or 6" duct
FV-08VRE1
Compatible Dimmers (Not Included)
Specifi cations: WhisperRecessedLED FV-08VRE1 4" or 6" Duct
Static Pressure in inches w.g. 0.1 0.25
Air Volume (CFM) 80 66
Noise (sones) 0.8 0.7
Power Consumption (watts) 20.5 19.5
Energy Ef ciency (CFM/Watt) 4.0 3.4
Speed (RPM) 1378 1501
Current (amps) 0.17 0.17
MAX Current (amps) 0.19
Power Rating (V/Hz) 120/60
ENERGY STAR rated YES
0.25 = Installed Performance
For complete Installation Instructions visit us.panasonic.com/ventfans