Table on Shifting Frequency Zone
Temperature, X (K) Zone Frequency No. Shifting (shifting direction):
(Intake Air - Internal Setting) Cooling Mode / Soft Dry Mode Heating Mode
X -2.5 0 Shift to Freq. MIN (↑) Shift to Freq. MAX (↓)
-2.5 < X -1.5 1 Shift to Freq. MIN (↑) Shift to Freq. MAX (↓)
-1.5 < X -1.0 2 -2 Freq. No. (↑) +2 Freq. No. (↓)
-1.0 < X -0.5 3 -1 Freq. No. (↑) +1 Freq. No. (↓)
-0.5 < X +1.0 4 Same Freq. No. Same Freq. No.
+0.5 < X +1.0 5 +1 Freq. No. (↓) -1 Freq. No. (↑)
+1.0 < X +1.5 6 +2 Freq. No. (↓) -2 Freq. No. (↑)
+1.5 < X +2.5 7 Shift to Freq. MAX (↓) Shift to Freq. MIN (↑)
X > +2.5 8 Shift to Freq. MAX (↓) Shift to Freq. MIN (↑)
Besides, the range of operation frequency will change according to the setting environment as listed below:
Condition: Freq. no. for E9BKP Freq. no. for E12BKP Remarks
MIN MAX MIN MAX
Cooling Mode 1 15 1 30 (a)
- if remote controller set 28°C & fan speed =
Hi
7 15 7 30 (a), (c)
- if remote controller set 28°C & fan speed =
Me-, Me, Me+, Auto
5 15 6 30 (a), (c)
- if remote controller set 28°C & fan speed =
Lo
4 15 5 30 (a), (c)
- if Powerful Mode ON 7 15 7 30 (a), (c)
Soft Dry Mode 4 7 4 8
Heating Mode 1 16 1 30 (b)
- if remote controller set 18°C & fan speed =
Hi
10 16 10 30 (b), (d)
- if remote control set 18°C & fan speed =
Me-, Me, Me+, Auto
9 16 9 30 (b), (d)
- if remote controller set 18°C & fan speed =
Lo
8 16 8 30 (b), (d)
- if Powerful Mode ON 10 16 10 30 (b), (d)
Remark:
(a) If frequency shifts up from MAX, the following frequency performed will be depending to outdoor temperature, as given in below table (for
30 seconds only) and then continues as normal rule.
Outdoor Temperature, X (°C) Frequency No.
X 30 13
X<30 7
(b) (If frequency shifts up from Freq. No. 17, the following frequency performed is as below (for 30 seconds only) and then continue as normal
rule.
Outdoor Temperature, X (°C) Frequency No.
X 10 10
X X<10 13
X<4 17
(c) When temperature different (intake - setting) < -1.0 K or Thermo-Off activated and only valid for 120 seconds; not applicable during Sleep
Mode, Soft Dry Mode, and Anti-freezing control.
(d) When temperature different (intake - setting) > +1.5 K or Thermo-Off activated and only valid for 130 seconds.
19
CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5