Panasonic CS-S9MKR, CU-S9MKR, CS-S12MKR, CU-S12MKR, CS-S18MKR Operating Instructions Manual

...
Page 1
Operating Instructions
QUICK GUIDE
Air Conditioner
Model No. Indoor Unit Outdoor Unit
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
QUICK GUIDE
F568153-YS0611-1_EN.indd 1F568153-YS0611-1_EN.indd 1 21-Jun-11 10:52:59 AM21-Jun-11 10:52:59 AM
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2011. Unauthorized copying and distribution is a violation of law.
F568153
Page 2
Thank you for purchasing
NOTE
OPERATION CONDITION
TABLE OF CONTENTS
WARNING
CAUTION
WARNING
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Panasonic Air Conditioner
TABLE OF CONTENTS
SAFETY PRECAUTIONS
REMOTE CONTROL
INFORMATION
INDOOR UNIT
2~3
4~5
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property damage, please comply with the following. Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:
WARNING
CAUTION
The instructions to be followed are classifi ed by the following symbols:
5
6
This sign warns of death or serious injury.
This sign warns of injury or damage to property.
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is COMPULSORY.
TROUBLESHOOTING
QUICK GUIDE
BACK COVER
NOTE
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
OPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (°C)
COOLING
Max. 32 23
Min. 16 11
CU-S9MKR, CU-S12MKR, CU-S18MKR
Temperature (°C)
COOLING
CU-S24MKR, CU-S28MKR
Max. 46 26
Min. 5 4
Temperature (°C)
COOLING
Max. 46 26
Min. 16 11
* DBT: Dry bulb temperature * WBT: Wet bulb temperature
2
7
Indoor
*DBT *WBT
Outdoor
*DBT *WBT
Outdoor
*DBT *WBT
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re.
Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
Do not expose yourself directly to cold air for a long period to avoid excess cooling.
Do not sit or step on the unit, you may fall down accidentally.
Indoor
Unit
Remote
Control
Air Outlet
Outdoor
Unit
Air Inlet
Air Inlet
Air Outlet
Power
Supply
F568153-YS0611-1_EN.indd 2F568153-YS0611-1_EN.indd 2 21-Jun-11 10:53:03 AM21-Jun-11 10:53:03 AM
Page 3
CAUTION
WARNING
WARNING
REMOTE CONTROL
Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
POWER SUPPLY
Do not use modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.
To prevent overheating, fi re or electric shock:
• Do not share the same power outlet with other equipment.
• Do not operate with wet hands.
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting or pulling out the power plug.
If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re.
To prevent overheating, fi re or electric shock:
• Insert the power plug properly.
• Dust on the power plug should be periodically wiped with a dry cloth.
Stop using the product when any abnormality/ failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock)
Examples of abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is observed.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is switched on for operation.
• The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/repair.
This equipment must be earthed to prevent electrical shock or fi re.
Prevent electric shock by switching off the power supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene, thinner or scouring powder to avoid damage or corrosion at the unit.
Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.
Do not use any combustible equipment in front of the airfl ow outlet to avoid fi re propagation.
Do not expose plants or pet directly to airfl ow to avoid injury, etc.
Do not touch the sharp aluminium fi n, sharp parts may cause injury.
Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
Do not install the unit in oily and smoky areas to prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to avoid injury.
Do not step onto unstable bench when cleaning the unit to avoid injury.
Do not place vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.
Do not open window or door for long time during COOL/DRY mode operation.
Ensure drainage pipe is connected properly and keep drainage outlet clear of gutters, containers or does not immersed in water to prevent water leakage.
After long period of use or use with any combustible equipment, aerate the room regularly.
After long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.
To prevent malfunction or damage of the remote control:
• Remove the batteries if the unit is not going to be used for a long period of time.
• New batteries of the same type must be inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to prevent electric shock.
3
F568153-YS0611-1_EN.indd 3F568153-YS0611-1_EN.indd 3 21-Jun-11 10:53:08 AM21-Jun-11 10:53:08 AM
Page 4
REMOTE CONTROL
R
MOD
E
ON
OFF
SET
CANCEL
TIM
ER
POWERFUL AIR SWING
FAN SPEED
ECO
NOMY
12
3
SET
CHECK
CLOCK RESET
AC RC
MOD
E
AIR
CONDITIONER
OFF/ON
Press the remote control’s button
Maximum distances: 8m
Remote Control display
3
8
9
10
11
13
INDICATOR
POWER
TIMER
QUIET/ECONOMY
POWERFUL
(Green) (Orange) (Orange) (Orange)
7
4
1
TO TURN ON OR OFF THE UNIT
• Please be aware of the OFF indication on the remote control display to prevent the unit from starting/stopping improperly.
2
TO SET TEMPERATURE
•
Selection range: 16˚C ~ 30˚C (Not applicable for FAN mode).
•
Operating the unit within the recommended temperature could induce energy saving. COOL mode : 26˚C ~ 28˚C. DRY mode : 1˚C ~ 2˚C lower than room temperature.
3
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• During operation mode selection the power indicator blinks.
• Unit selects operation mode during startup according to temperature setting and room temperature.
COOL mode - To enjoy cool air
• Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode.
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling operation.
FAN mode - To circulate air in the room
1
2
5
4
TO SELECT FAN SPEED (5 OPTIONS)
FAN SPEED
• For AUTO, the indoor fan speed is automatically adjusted
according to the operation mode.
TO ADJUST VERTICAL AIRFLOW DIRECTION
5
(5 OPTIONS)
AIR SWING
12
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swing
up/down automatically.
POWE
S9MKR, S12MKR
MODE
POWERFUL
ECONOMY
AIR SWING
FAN SPEED
S18MKR, S24MKR, S28MKR
6
4
F568153-YS0611-1_EN.indd 4F568153-YS0611-1_EN.indd 4 21-Jun-11 10:53:13 AM21-Jun-11 10:53:13 AM
6
TO ADJUST AIRFLOW DIRECTION (5 OPTIONS)
AIR SWING
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swing
left/right and up/down automatically.
TO SAVE ELECTRICAL POWER
7
CONSUMPTION
QUIET/ECONOMY
• Save power consumption at unoccupied room by adjust
set temperature up to 3°C automatically.
• Brightness of all indicators will be dimmed.
Page 5
TO SET THE TIMER
8
NOTES
TO REACH TEMPERATURE QUICKLY
• This operation will stop automatically after 20 minutes.
9
TO ENJOY QUIET OPERATION
• This operation reduces airfl ow noises.
Press and hold for 5 seconds to dim or restore the
10
unit’s indicator brightness.
Press and hold for approximately 10 seconds to
11
show temperature setting in °C or °F.
12
Press to restore the remote control’s default setting.
13
Not used in normal operations.
NOTES
POWERFUL
,
ECONOMY
,
POWERFUL
QUIET/ECONOMY
• Can be activated in all modes and can be cancelled by pressing the respective button again.
POWERFUL
,
ECONOMY
,
• Cannot be selected at the same time.
TO SET THE TIMER
• 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time.
• Complete below procedures to set each timer:
ON
1
OFF
Select ON or OFF timer
Cancel
Cancel
2
Set the
time
SET
3
Confi rm
• Example of application at living room:
Morning: ON
at 07:00 (Wake up)
OFF at 08:00 (Out for work)
Evening: ON at 17:00 (Back home)
OFF at 22:00 (Sleep)
CANCEL
OFF
to
.
• To cancel ON or OFF timer, press ON or
select respective or then press
• If timer is cancelled manually or due to power failure,
you can restore the timer again by pressing ON or
OFF
to select respective or then press
SET
.
• Upcoming timer will be displayed and will be activated in sequence.
• When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover.
INFORMATION
FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select Cooling operation. After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: Cooling: ≥ 8°C
FOR EXTENDED NON-USE
• Turn off the power supply and unplug.
• Remove the remote control batteries.
F568153-YS0611-1_EN.indd 5F568153-YS0611-1_EN.indd 5 21-Jun-11 10:53:18 AM21-Jun-11 10:53:18 AM
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND UNPLUG then please consult authorized dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
5
Page 6
INDOOR UNIT
CLEANING INSTRUCTIONS
HINT
• Switch off the power supply and unplug before cleaning.
CAUTION
• Do not touch the aluminium fi n, sharp parts may cause injury.
CLEANING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap ( pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
2
8
5
6
1
INDOOR UNIT
• Wipe the unit gently with a soft, dry cloth.
2
FRONT PANEL
Remove Front Panel
• Raise and pull to remove the front panel.
• Wash gently and dry.
Close Front Panel
• Press down both ends of the front panel to close it securely.
3
REMOTE CONTROL RECEIVER
4
ALUMINIUM FIN
5
HORIZONTAL AIRFLOW DIRECTION LOUVER
S9MKR, S12MKR
• Manually adjustable.
S18MKR, S24MKR, S28MKR
• Do not adjust by hand.
6
HINT
• To ensure optimal performance of the unit, cleaning maintenance has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H99”. Please consult authorized dealer.
4
6
VERTICAL AIRFLOW DIRECTION LOUVER
• Do not adjust by hand.
7
AUTO OFF/ON BUTTON
• Use when remote control is misplaced or a malfunction occurs.
Press once. Auto Press and hold until 1 beep is
heard, then release. Press the button to turn off.
8
• Vacuum the fi lter whenever necessary.
• Replace the fi lter every 10 years or replace any damaged fi lter.
Part no.: CZ-SA22P
9
• Air fi lter cleaning is required every two weeks.
• Wash/rinse the fi lters gently with water to avoid damage to the
fi lter surface.
• Dry the fi lters thoroughly under the shade, away from fi re or
direct sunlight.
• Replace any damaged fi lters.
Action Mode
AIR PURIFYING FILTER
Vacuum the air purifying fi lter.
AIR FILTERS
1
7
9
3
Cooling
F568153-YS0611-1_EN.indd 6F568153-YS0611-1_EN.indd 6 21-Jun-11 10:53:25 AM21-Jun-11 10:53:25 AM
Page 7
TROUBLESHOOTING
The following symptoms do not indicate malfunction.
SYMPTOM
CAUSE
Check the following before calling for servicing.
SYMPTOM
CHECK
The following symptoms do not indicate malfunction.
Mist emerges from indoor unit. ► • Condensation effect due to cooling process. Water fl owing sound during operation. ► • Refrigerant fl ow inside the unit. The room has a peculiar odour. ► • This may be due to damp smell emitted by the wall,
Indoor fan stops occasionally during automatic fan speed setting.
Operation is delayed a few minutes after restart. ► • The delay is a protection to the unit’s compressor. Outdoor unit emits water/steam. ► • Condensation or evaporation occurs on pipes. Timer indicator is always on. ► • The timer setting repeats daily once set. Power indicator blinks before the unit is switched on. ► • This is a preliminary step in preparation for the operation
Cracking sound during operation. ► • Changes of temperature cause the expansion/contraction
Check the following before calling for servicing.
Cooling operation is not working effi ciently. ► • Set the temperature correctly.
Noisy during operation. ► • Check if the unit has been installed at an incline.
Remote control does not work. (Display is dim or transmission signal is weak.)
The unit does not work. ► • Check if the circuit breaker is tripped.
The unit does not receive the signal from the remote control.
SYMPTOM
SYMPTOM
CAUSE
carpet, furniture or clothing.
► • This helps to remove the surrounding odours.
when the ON timer has been set.
of the unit.
CHECK
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
• Close the front panel properly.
► • Insert the batteries correctly.
• Replace weak batteries.
• Check if timers have been set.
► • Make sure the receiver not obstructed.
• Certain fl uorescent lights may interfere with signal
transmitter. Please consult authorized dealer.
The unit stops and the timer indicator blinks.
Use remote control to retrieve error code.
Press for 5
1
seconds.
Press for 5
3
seconds to quit checking.
Turn the unit off and reveal the error code to authorized dealer.
4
TIMER
ON
123
OFF
SET CHECK CLOCK RESET
SET
CANCEL
AC
Press until you hear
2
beep sound, then write down the error
RC
code.
Note:
• For certain errors, you may restart the unit for limited operation with 4 beeps during operation starts.
7
F568153-YS0611-1_EN.indd 7F568153-YS0611-1_EN.indd 7 21-Jun-11 10:53:31 AM21-Jun-11 10:53:31 AM
Page 8
QUICK GUIDE
MODE
OFF/ON
TEMP
Remote Control Preparation
Remote Control Preparation
1
2
3
4 5 6
TIMER
ON
123
OFF
SET CHECK CLOCK RESET
1
AUTO COOL
FAN DRY
Select the desired mode.
2
Start/stop the operation.
3
Select the desired temperature.
SET
CANCEL
AC
RC
MODE
OFF/ON
TEMP
Pull out
1
Insert AAA or R03 batteries (can be used ~ 1 year)
2
Close the cover
3
Press CLOCK
4
Set time
5
6
Confi rm
AIR CONDITIONER
MODE
OFF/ON
MODE
POWERFUL AIR SWING
TIMER
ON
123
OFF
SET CHECK CLOCK RESET
ECONOMY
FAN SPEED
SET
CANCEL
AC RC
AIR CONDITIONER
MODE
2
OFF/ON
1
MODE
POWERFUL
3
TIMER
ON
123
OFF
SET CHECK CLOCK RESET
ECONOMY
AIR SWING
FAN SPEED
SET
CANCEL
AC RC
S9MKR, S12MKR
S18MKR, S24MKR,
S28MKR
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
Pb
Panasonic Corporation
Website: http://panasonic.net/
Printed in Malaysia
F568153-YS0611-1_EN.indd 8F568153-YS0611-1_EN.indd 8 21-Jun-11 10:53:36 AM21-Jun-11 10:53:36 AM
F568153
YS0611-1
Loading...