Before operating the unit, read these Before operating the unit, read these
operating instructions thoroughly and operating instructions thoroughly and
keep them for future reference.keep them for future reference.
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that
is PROHIBITED.
To prevent personal injury, injury to others, or property damage, please observe the following.
Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classifi ed as below:
Warning
This sign warns of death or serious injury.
These symbols denote actions that
are COMPULSORY.
Caution
This sign warns of
injury or damage
to property.
Remote Control
• Do not use rechargeable
(Ni-Cd) batteries.
• Do not allow infants and
small children to play
with the remote control
to prevent them from
accidentally swallowing the
batteries.
• Remove the batteries if the
unit is not going to be used
for a long period of time.
• New batteries of the same
type must be inserted
following the polarity stated
to prevent malfunction of
the remote control.
Power Supply
• Do not share the same power outlet with
other equipment.
• Do not modify power cords.
• Do not use extension cords.
• Do not operate with wet hands.
• Use the specifi ed supply cord.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualifi ed persons in
order to avoid a hazard.
• This equipment must be earthed and
strongly recommended to be installed
with Earth Leakage Circuit Breaker
(ELCB) or Residual Current Device
(RCD). Otherwise, it may cause electrical
shock or fi re in case of malfunction.
• In case of emergency or abnormal
conditions (burnt smell, etc), turn off
the power supply, and please consult
authorized dealer.
Indoor Unit
• Do not install, remove and
reinstall the unit by yourself;
improper installation will
cause leakage, electric
shock or fi re. Please
consult authorized dealer or
specialist for the installation
work.
• Do not insert your fi ngers or
other objects into the unit,
rotating parts may cause
injury.
• Do not attempt to repair the
unit by yourself.
Air inletAir inlet
Air Air
outletoutlet
Air inlet
Air
inlet
Air outlet
Indoor Unit
• Do not install the unit in a
potentially explosive atmosphere.
• Do not wash the unit with water,
benzene, thinner or scouring
powder.
• Do not use for other purposes
such as preservation of food.
• Do not use any combustible
equipment in front of the airfl ow
outlet.
• Do not expose directly to cold air
for a long period.
• Ensure that the drainage pipe is
connected properly. Otherwise,
leakage may occur.
• Aerate the room regularly.
Power Supply
• Switch off the power supply
before cleaning or servicing.
• Turn off the power supply if the
unit is not used for a long period
of time.
• This air conditioner is equipped
with a built-in surge protective
device. However, in order
to further protect your air
conditioner from being damaged
by abnormally strong lightning
activity, you may want to
disconnect it from the power
supply. Do not touch the air
conditioner during lightning,
it may cause electric shock.
Outdoor Unit
• Do not sit or step on the unit, you
may fall down accidentally.
• Do not touch the sharp aluminum
Outdoor Unit
• Do not insert your fi ngers or other objects
into the unit, rotating parts may cause
8
injury.
fi n, sharp parts may cause injury.
• After long periods of use, make
sure the installation rack is not
damaged.
REGULATORY INFORMATION REGULATORY INFORMATION
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
OPERATION CONDITIONOPERATION CONDITION
Use this air conditioner under the following temperature range
(CU-PC30JKF)
Temperature (°C)
COOLING
(CU-PC36JKF)
Temperature (°C)
COOLING
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
Maximum32235531
Minimum16111611
Maximum32235231
Minimum16111611
IndoorOutdoor
*DBT*WBT*DBT*WBT
IndoorOutdoor
*DBT*WBT*DBT*WBT
Thank you for purchasing
Panasonic Air Conditioner
TABLE OF CONTENTSTABLE OF CONTENTS
SAFETY PRECAUTIONS
REGULATORY INFORMATION
PRODUCT OVERVIEW &
OPERATIONS
10~11
CARE & CLEANING
12
TROUBLESHOOTING
13
QUICK GUIDE
BACK COVER
NOTE :NOTE :
The illustrations in this manual are
for explanation purposes only and
may differ from the actual unit. It is
subjected to change without notice
for future improvement.
8
9
ENGLISH
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your
local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the
requirement set by the Directive for the chemical involved.
Pb
• Do not switch ON the unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
• Do not install the unit in oily and smoky areas.
• Used when remote control is misplaced
or malfunction.
ActionMode
Press once.Auto
Press and hold until 1 beep
is heard, then release.
Cooling
Press the button to turn off.
INDICATOR
POWER
(Green)
TIMER
(Orange)
10
TO TURN ON OR OFF THE UNIT
• Please be aware of the OFF indication on the remote
control display to prevent the unit from starting/
stopping improperly.
TO SET THE TIMER TO SET THE TIMER
• To turn ON or OFF the unit at a preset time.
TO SET TEMPERATURE
• Selection range : 16°C ~ 30°C.
• Operating the unit within the recommended
temperature could induce energy saving.
COOL mode : 26˚C ~ 28˚C.
DRY mode : 1˚C ~ 2˚C lower than room temperature.
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• Unit selects the operation mode according to the
room temperature.
COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle
cooling operation.
TO SELECT FAN SPEED
(3 OPTIONS)
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
TO ADJUST VERTICAL AIRFLOW
DIRECTION (4 OPTIONS)
• Keeps the room ventilated.
• If AUTO is set, the louvers swing up/down
automatically.
Select ON or
Set the time.Confi rm.
OFF timer.
• To cancel ON or OFF timer, press
or then
press .
• When ON Timer is set, the unit may start earlier (up
to 15 minutes) before the actual set time in order to
achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote
control and repeats daily once set. For clock setting,
please refer to Remote Control Preparation at back
cover.
• If timer is cancelled manually or due to power failure,
you can restore the previous setting (once power is
resumed) by pressing
.
OPTIONAL SETTINGS OPTIONAL SETTINGS
Press and hold for approximately 10
seconds to show temperature setting in
°C or °F.
Press and hold for approximately 5 seconds
to show 12-hour (am/pm) or 24-hour time
CLOCK
indication.
Press to restore the remote control’s default
RESET
setting.
Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
ENGLISH
11
CARE & CLEANING CARE & CLEANING
• Switch off the power supply before cleaning.
CAUTION
WASHING INSTRUCTIONSWASHING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap (
• Do not use water hotter than 40°C.
•Do not touch the aluminium fi n, sharp parts may cause injury.
pH7) or neutral household detergent.
HINT HINT
• To ensure optimal performance of the unit, cleaning
maintenance have to be carried out at regular intervals.
Please consult authorized dealer.
ALUMINIUM FINALUMINIUM FIN
RemoveRemove
AIR FILTERS AIR FILTERS
• Air filters cleaning is needed every two weeks.
• Wash/rinse the fi lter gently with water to avoid
damage to the fi lter surface.
• Dry the fi lters thoroughly under the shade, away from fi re or direct sunlight.
• Replace any damaged fi lter.
FOR SEASONAL INSPECTION AFTER EXTENDED FOR SEASONAL INSPECTION AFTER EXTENDED
NON-USENON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the
following temperature difference between air inlet and air
outlet vents:
Cooling: ≥ 8°C
FOR EXTENDED NON-USEFOR EXTENDED NON-USE
• Turn off the power supply.
• Remove the remote control batteries.
12
FRONT PANELFRONT PANEL
Remove Front Panel
• Raise and pull to remove the
front panel.
• Wash gently and dry.
Close Front Panel
• Press down both ends of the
front panel to close it securely.
INDOOR UNITINDOOR UNIT
Wipe the unit gently with a soft,
dry cloth.
NON SERVICEABLE CRITERIASNON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult
authorized dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
TROUBLESHOOTING TROUBLESHOOTING
The following symptoms do not indicate malfunction. The following symptoms do not indicate malfunction.
SymptomSymptomCauseCause
Mist emerges from indoor unit.• Condensation effect due to cooling process.
Water fl owing sound during operation.• Refrigerant fl ow inside the unit.
The room has a peculiar odour.• This may due to damp smell emitted by the wall, carpet, furniture or
Indoor fan stops occasionally during automatic
fan speed setting.
Operation is delayed a few minutes after
restart.
Outdoor unit emits water/steam.• Condensation or evaporation occurs on pipes.
Timer indicator is always on.• The timer setting repeats daily once set.
Cracking sound during operation. • Changes of temperature cause the expansion/contraction of the unit.
Check the following before calling for servicing. Check the following before calling for servicing.
SymptomSymptomCheckCheck
Cooling operation is not working effi ciently.• Set the temperature correctly.
Noisy during operation.• Check if the unit has been installed at an incline.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.• Check if the circuit breaker is tripped.
The unit does not receive the signal from the
remote control.
clothing.
• This helps to remove the surrounding odours.
• The delay is a protection to the unit’s compressor.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
• Close the front panel properly.
• Insert the batteries correctly.
• Replace weak batteries.
• Check if timers have been set.
• Make sure the receiver not obstructed.
• Certain fl uorescent lights may interfere with signal transmitter. Please
consult authorized dealer.