Overview
The AN6701S is an integrated circuit designed for tempera­ture sensing. Since a temperature characteristic adjusting cir­cuit and buffer amp. in addition to temperature sensor circuit are integrated, the temperature sensing operation with high sen­sitivity as well as high precision can easily be done by a single external resistor.
High sensitivity (100mV/˚C)
Excellent linearity (non linearity.±0.5%)
Easy calibration with an external resistor
High precision (±1˚C) with calibration
AN6701S
Temperature Sensor IC
1 2 3 4
0.4±0.25
0.6±0.31.27
0.1±0.1
0.3
0.15
0.65
1.5±0.2
5.0±0.3
4.2±0.3
6.5±0.3
8-pin PANAFLAT Plastic Package (SOP008-P-0225A)
8 7 6 5
Unit : mm
Block Diagram
Pin Descriptions
Pin No.
Pin name 1 2 3 4 5 6 7 8
V
CC
Output voltage GND R
C
NC NC NC NC
Temperature Detecter
Offset Temp. Adjuster
+
Buffer Amp.
1
V
CC
2
V
O
4
R
C
3
GND
V
CC
I
CC
P
D
T
opr
T
stg
Supply voltage Supply current Power dissipation Operating ambient temperature Storage temperature
V
mA
mW
˚C ˚C
Parameter Symbol Rating Unit
Absolute Maximum Ratings (Ta=25˚C)
16
4
70
–10 to + 80
–55 to +125
Parameter Symbol Condition min typ
Electrical Characteristics (Ta=–10˚C — +80˚C)
Supply voltage
V
CC
9
R
C
=10k, RL=
Supply current
I
CC
0.4
V
CC
=15V, RC=10k, RL=,
Ta=25˚C
Output voltage
V
O
2.3
Not calibrated
1)
, VCC=15V,
Ta=0˚C
4
Not calibrated
1)
, VCC=15V,
Ta=25˚C
10 11
Not calibrated
1)
, VCC=15V,
Ta=80˚C
1.1 1.2
Calibrated
2)
, VCC=15V,
Ta=–10˚C
8.6 8.8
Calibrated
2)
, VCC=15V,
Ta=60˚C
5
10.8 11
Calibrated
2)
, VCC=15V,
Ta=80˚C
Supply voltage fluctuate due to output change
DV
OV
0.15
R
C
=10k, Ta=0˚C,
V
CC
=5 to 15V
Non-linearity NL
±0.5
Not calibrated
1)
, VCC=15V,
Ta=0 to 80˚C
Output current
I
O
RC=10k, VCC=9V, Ta=25˚C, DV
O
=±50mV
100
5
0.2
1.3
Output resistance
R
O
30
Note1) RC=10k Note2) Adjust RC value to be VO=5.0V when Ta=25˚C
max
15 V
0.8 mA
3.3 V
V
V
V
V
V
V
±2 %
µA
200
6
12
1.4
9
11.2
0.22
Unit
Applicable temperature Sensitivity (R
C
=1 to 100k)
Non-linearity Offset temperature (R
C
=1 to 100k) Thermal constant τ (during quiescent airing) Thermal constant τ (during spray airing) Thermal resistance (during quiescent airing)
˚C
mV/˚C
%
˚C
s s
˚C/W
Parameter Value Unit
Typical Characteristics
–10 to + 80
104 to 112
±0.5
–30 to –10
24 11
300
Note) Offset temperature is a temperature in which output becomes “0” when input/output characteristics are
inserted externally.