Panasonic Industrial Company 5RS084FAA21
Air Conditioning Department 208/230V, 60Hz R-410a
5RS084FAA21
Application Cooling (C) / Heating (H)
Ref. Charge Limit (C/H) 22.4 oz. 635 g
(C) 26.5 oz. 750 g
Evaporating Temp Range (C/H)
(C)
5°F to 53.6 °F -15°C to 12°C
14°F to 53.6 °F -10°C to 12°C
Rated Performance at 230 V
Capacity 8,155 BTU/h
Motor Input 875 Watts
Current 3.95 Amperes
Compressor Data
Pump Type Rotary
Displacement 8.51 cm3/rev.
Oil FV50S (PVE)
or equivalent
Oil Charge (Precharged) 10.2 fl. Oz. 300 cm
Net Weight 20.6 lb. 9.30 kg
3
Motor Data
Motor Type Permanent Split Capacitor
Locked Rotor Amperes 21 A at 240 V
Winding Resistance
Max. Continuous Current
2
Main: ____Ω, Aux: ____Ω
2
_________
Maximum Operating Conditions
Condensing Temp. 149°F 65°C
Return Gas Temp. 95°F 35°C
Discharge Gas Temp. 239°F 115°C
Motor Wire Temp. 266°F 130°C
Electrical Components
Overload Protector 7100571
Texas Instrument part# MRA 99052-9201
Run Capacitor 15 µF / 370 V
Rated at ASHRAE/T Conditions
Evaporating Temp. 45°F 7.2°C
Condensing Temp. 130°F 54.4°C
Return Gas Temp. 95°F 35.0°C
Liquid Temp. 115°F 46.1°C
Ambient Temp. 95°F 35.0°C
Performance Data
Based on Voltage 230 V, Frequency 60 Hz
Return Gas 65°F 18.3°C
Liquid Sub Cooling 15°F -9.4°C
Ambient, Air Over 1m/s 95°F 35.0°C
EVAP. TEMP.
35°F
1.7°C
45°F
7.2°C
55°F
12.8°C
Btu/h 7588 7178 6723 6242 5758
Watts 617 694 769 838 899
Amperes 2.9 3.3 3.6 3.8 4.1
Btu/h 9273 8792 8289 7760 7202
Watts 609 700 780 855 924
Amperes 2.8 3.2 3.6 3.9 4.1
Btu/h 11225 10651 10046 9490 8839
Watts 600 697 780 863 935
Amperes 2.7 3.1 3.5 3.9 4.2
100°F 110°F 120°F 130°F 140°F
37.8°C 43.3°C 48.9°C 54.4°C 60°C
COND. TEMP.
UL file no.: To Be Confirmed 2Contact Panasonic for value