Panasonic 5RS072UAB21 User Manual

Panasonic Industrial Company 5RS072UAB21
Air Conditioning Department 115V, 60Hz R-410a
5RS072UAB21
Application Cooling (C) / Heating (H) Ref. Charge Limit (C/H) 16.4 oz. 465 g
(C) 19.4 oz. 550 g
Evaporating Temp Range (C/H) (C)
5°F to 53.6 °F -15°C to 12°C 14°F to 53.6 °F -10°C to 12°C
Rated Performance at 115 V
Capacity 6,926 BTU/h Motor Input 720 Watts Current 6.60 Amperes
Pump Type Rotary Displacement 7.26 cm3/rev. Oil FV50S (PVE)
or equivalent Oil Charge (Precharged) 10.14 fl. oz. 300 cm Net Weight 20.1 lb. 9.10 kg
3
Motor Data
Motor Type Permanent Split Capacitor Locked Rotor Amperes 40 A at 120 V Winding Resistance Max. Continuous Current
2
Main: ____Ω, Aux: ____Ω
2
_________
Maximum Operating Conditions
Condensing Temp. 149°F 65°C Return Gas Temp. 95°F 35°C Discharge Gas Temp. 239°F 115°C Motor Wire Temp. 266°F 130°C
Electrical Components
Overload Protector 7100533 Texas Instrument part# MRA 98866-9201 Run Capacitor 35 µF / 250 V
Rated at ASHRAE/T Conditions
Evaporating Temp. 45°F 7.2°C Condensing Temp. 130°F 54.4°C Return Gas Temp. 95°F 35.0°C Liquid Temp. 115°F 46.1°C Ambient Temp. 95°F 35.0°C
Performance Data
Based on Voltage 115 V, Frequency 60 Hz Return Gas 65
°F 18.3°C
Liquid Sub Cooling 15°F -9.4°C Ambient, Air Over 1m/s 95
°F 35.0°C
EVAP. TEMP.
35°F
1.7°C
45°F
7.2°C
55°F
12.8°C
Btu/h 3293 3043 2756 2508 2217
Watts 521 586 649 708 759
Amperes 4.9 5.5 6.1 6.4 6.9
Btu/h 7973 7560 7127 6673 6193
Watts 514 591 659 722 780
Amperes 4.9 5.5 6.3 6.6 7.1
Btu/h 9652 9158 8638 8160 7601
Watts 512 589 659 729 790
Amperes 4.8 5.5 6.3 6.8 7.2
100°F 110°F 120°F 130°F 140°F
37.8°C 43.3°C 48.9°C 54.4°C 60°C
COND. TEMP.
UL file no.: To Be Confirmed 2Contact Panasonic for value
Loading...