Panasonic 5PS102UCA21 User Manual

Panasonic Industrial Company 5PS102UCA21
Air Conditioning Department 115V, 60Hz R-410a
5PS102UCA21
Application Cooling (C) / Heating (H) Ref. Charge Limit (C/H) 28.2 oz. 635 g
(C) 26.5 oz. 750 g
Evaporating Temp Range (C/H) (C)
5°F to 53.6 °F -15°C to 12°C 14°F to 53.6 °F -10°C to 12°C
Rated Performance at 115 V
Capacity 9,880 BTU/h Motor Input 1050 Watts Current 9.30 Amperes
Pump Type Rotary Displacement 10.2 cm3/rev. Oil FV50S (PVE)
or equivalent Oil Charge (Precharged) 11.83 fl. Oz. 350 cm Net Weight 25.6 lb. 11.6 kg
3
Motor Data
Motor Type Permanent Split Capacitor Locked Rotor Amperes 53 A at 120 V Winding Resistance Max. Continuous Current
2
Main: ____Ω, Aux: ____Ω
2
_________
Maximum Operating Conditions
Condensing Temp. 149°F 65°C Return Gas Temp. 95°F 35°C Discharge Gas Temp. 239°F 115°C Motor Wire Temp. 266°F 130°C
Electrical Components
Overload Protector 7100032 Texas Instrument part# MRA 98695 Run Capacitor 40 µF / 250 V
Rated at ASHRAE/T Conditions
Evaporating Temp. 45°F 7.2°C Condensing Temp. 130°F 54.4°C Return Gas Temp. 95°F 35.0°C Liquid Temp. 115°F 46.1°C Ambient Temp. 95°F 35.0°C
Performance Data
Based on Voltage 115 V, Frequency 60 Hz Return Gas 65°F 18.3°C Liquid Sub Cooling 15°F -9.4°C Ambient, Air Over 1m/s 95°F 35.0°C
EVAP. TEMP.
35°F
1.7°C
45°F
7.2°C
55°F
12.8°C
Btu/h 9390 8806 8248 7658 7064
Watts 750 845 936 1020 1094
Amperes 6.7 7.7 8.6 9.0 9.6
Btu/h 11376 10786 10169 9520 8836
Watts 740 851 949 1040 1124
Amperes 6.7 7.8 8.8 9.2 9.9
Btu/h 13771 13067 12324 11642 10844
Watts 737 848 949 1050 1138
Amperes 6.6 7.8 8.9 9.3 10.0
100°F 110°F 120°F 130°F 140°F
37.8°C 43.3°C 48.9°C 54.4°C 60°C
COND. TEMP.
UL file no.: To Be Confirmed 2Contact Panasonic for value
Loading...