Split System Submittal Data
System: 36PET1U6 Indoor: S-36PT1U6 Outdoor: U-36PE1U6
Single Split System - Ceiling-Suspended Heat Pumps
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz) 230/208/1/60
Circuit Ampacity (A) 15-35 Indoor-Outdoor
Fuse Size, Max.(A) 15-35 Indoor-Outdoor
Compressor DC Rotary Inverter
No. Used 1
R.L. Amps - L.R. (A) 16.4 - 17.5
Outdoor Unit
Fan type Propeller
Dia & Length (in.) - No. used 18-7/64-1
Type Drive - No. Speeds DC Motor
No. Poles (RPM) 8 - 830
No. Motors (W) 1 - 90
CFM (High) 1942
F.L. Amps (A) 17.3
Coil Type Aluminum Fin & Copper Pipe
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I. 2 - 14.1
Face Area (sq.ft.) 7.26
Tube Size (in) 3/8"
Indoor Unit
Fan type Centrifugal
Dia & Length (in.) - No. used 5-29/32-4
No. Speeds 3 & Auto
No. Poles (RPM, High) 4 - 1040
No. Motors (W) 1 - 100
CFM (HI/Med/Lo) 1100/930/750
Indoor Sound Rating (Hi) (dB-A) 42
F.L. Amps (A) 0.8
Coil Type
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I. 3 - 14.9
Face Area (sq.ft.) 3.51
Tube Size (in) 9/32"
Drain Connection Size (in.) 1-3/128"
Aluminum Plate Fin & Copper Tube
Approval:
Date:
Construction:
Unit#:
Drawing#:
Refrigerant R410A
Lbs. - R410a 6.17
Control Electric Expansion Valve
Connection Flare
Line Length, Max (ft.) 165
Line Difference, Max (ft.) 50 (outdoor lower),
100 (outdoor higher)
Line Size (in. O.D. Discharge) 3/8"
Line Size (in. O.D. Suction) 5/8"
Dimensions (HxWxD)
Indoor Unit (Crated) (in.) 12-15/32 x 66-1/16 x 31-1/16
Indoor Unit (Uncrated) (in.) 9-7/16 x 62-1/32 x 26-3/8
Outdoor Unit (Crated) (in.) 34-31/32 x 39-31/32 x 16-3/32
Outdoor Unit (Uncrated) (in.) 30-23/32 x 37 x 13-3/8
Weight (lbs.)
(Indoor) Net 84
(Indoor) Shipping 97
(Outdoor) Net 143
(Outdoor) Shipping 161
(Indoor) Shipping Volume (cu.ft.) 14.8
(Outdoor) Shipping Volume (cu.ft.) 13
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity (BTU/H) 31,200 (9,500 - 31,200)
Sensible Capacity (BTU/H) 19,800
Latent Capacity (BTU/H) 11,400
SEER 15.1
Dehumidification (Pints/H) 10.0
Amps (A) 18.2/20.1
Power Inputs (W) 3,840/3,840
Outdoor Sound Rating (dB-A) High 52
Heating
Total Capacity (BTU/H) 37,400 (8,000 - 37,400)
HSPF 9.6
Amps (A) 15.6/17.3
Max Amps (A) 15.6/17.3
Power Inputs (W) 3,250/3,250
Back-up Strip Heather (KW) N/A
Outdoor Sound Rating (dB-A) High 52
Features
Controls Microprocessor
Remote Controller (Wired Remote Included)
Temperature Control IC Thermostat
Timer 72 Hr. On/Off
Night Setback N/A
Air Louver, Horizontal Manual
Air Louver, Vertical Automatic
Power Failure Automatic
Changeover
Heating/Cooling Automatic
Changeover
Self-Diagnosis Built-In
Air Filter Washable, Anti-Mold
(Wireless Remote Optional)
Built-In
Built-In
Option
Refrigerant Line Set Available
Fresh Air Intake Knock-out
Airduct Extension N/A
Indoor Frame Extension N/A
Condensate Drain Pump Optional Accessory
Non-Removeable Locking
Remo-con Bracket
Operating Range
Cooling (Max) 95F DB/71F WB 115F DB
Cooling (Min) 67 DB/57F WB 0F DB
Heating (Max) 80F DB/67F WB 75F DB/65F WB
Heating (Min) -DB/-WB 5F DB
Indoor Air Intake Temp
Available
Outdoor Air Intake Temp
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon