Panasonic 3312F, 3312FL User Manual

Fire alarm systems
Common base for the different analog detectors
Fast connectors
Label holder recess
Analog base
Common base
The analog base 3312F / FL is connected to a COM loop. Analog heat, smoke and multi detector types 33xx / 43xx can be plugged in the base. (See Product Leaflet for the detector type respectively, for type of base.)
Fast connectors
3312F has fast connectors (blue) for the COM loop (in/out). 3312FL also has fast connectors (grey) for an external indicator (LED), e.g. 2218.
Label holder
A label holder could be mounted in the base (in the label holder recess). The label holder is intended for a label showing "zone­address" or "technical number" information, which can be read also when the detector is plugged in the base.
Miscellaneous
The base has an address label (Al) where the detector's COM loop address is to be written.
Individual fault signal is obtained if wrong type of detector (compared with the programming) is plugged in the base or if the detector is unplugged.
When a detector with a locking screw is plugged in the base, the detector can be locked in its base to prevent theft.
The position of the detector's built-in LED is marked in the base for correct mounting position of the base.
For more information regarding detector types, connections, etc. see Planning Instructions and connection diagrams for the system respectively.
Product applications
Used for analog detectors in the systems EBL512 / 128 / 1000 / 2000.
The base is intended for indoor use and in dry premises.
Panasonic Electric Works Fire & Security Technology Europe AB Jungmansgatan 12, SE-211 19 Malmö, Sweden Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 info-fste@eu.pewg.panasonic.com • www.panasonic-fire-security.com
.
Type number
3312F Analog base with fast connectors (blue) for the COM loop. 3312FL Analog base with fast connectors (blue) for the COM loop and fast
connectors (grey) for one ext. LED (e.g. 2218). 3390 Label holder (100 holders per packet, excl. labels) 3391 Labels for 3390 (10 sheets à 132 labels)
Ext LED
E
+
Al
IN OUT
A
S
Connectors E+ and E­not on 3312F
E
-
Lss (33xx)
SA Fast connector for COM loop (in/out)
Lss (430x)
S
SB Fast connector for COM loop (in/out)
B
Al Address Label
50 mm 73 mm
Lss Locking screw stopper (for detector type 33xx and 430x respectively)
E- Fast connector for external LED
15
6.2
102 mm
E+ Fast connector for external LED
NOTE! E- and E+ on 3312FL only.
The base is prepared for mechanical locking of the detector, when a detector with a locking screw is plugged into the base. Connector wire 0.6 – 1.2 mm (approx. 0.28 – 1.13 mm
2
). If wire 0.6 mm is used the release button may be pushed as the wire is pressed into the connector. Analog detector types 33xx and 43xx can be plugged in the base 3312F / FL.
Technical data
Voltage (V DC) Rated
allowed normal
Current consumption at nom. volt. from COM loop (mA)
quiescent (base only) active (base only)
Ext. LED connectors (3312FL only) voltage (V)
max. current output (mA) Ambient temperature (°C)
Operating storage
Ambient humidity (% RH) max. 95, non condensing Ingress Protection rating (estimated) IP51
Size x H (mm) Weight 3312F / 3312FL (g) 41 / 47 Construction / Colour ABS / Grey (N8, Munsell colour code)
Approvals CE; Conforms with EN54-5 and -7 (when applicable)
28 12-30 24 (COM loop voltage)
Depending on the type of detector that is plugged into the base.
0 0
Depending on the detector plugged in the base. Normally: 5
2
-10 to +50
-20 to +70
102 x 15
All technical features and data are subject to changes without notice, resulting from continuous development and improvement.
Product Leaflet Date of issue Revision / Date of revision
MEW01119 2008-09-19