Panasonic 2R11S3R236A-6A User Manual

Panasonic Industrial Company
2R11S3R236A-6A
Air Conditioning Department
2R11S3R236A-6A
Application Cooling(C) / Heating (H) Ref. Charge Limit (C/H) 16.4 oz. 465 g
(C) 19.4 oz. 550 g
Evap. Temp. Range (C/H) 5°F to 53.6°F -15°C to 12°C
(C) 14°F to 53.6°F -10°C to 12°C
Specification Number SC-52170825-A
Rated Performance @230V
Capacity 7,160 Btu/hr Motor Input 665 Watts Current 3.0 Amperes E.E.R. 10.77 Btu/hr/ W
Compressor Data
Pump Type Rotary Displacement 10.3 cc/rev Oil ATMOS M60 or equivalent Oil Charge (Precharged) 8.8 fl. oz. 260 cc Net Weight 19.2 lb 8.7 kg
1
208/230 V, 60 Hz R-22
BTU 7,000
R
Motor Data
Motor Type Permanent Split Capacitor Locked Rotor Amperes 19 A at 240 V Winding Resistance Main: 4.093W, Aux: 5.584W Max. Continuous Current
2
Maximum Operating Conditions
Condensing Temp. 149°F 65°C Return Gas Temp. 95°F 35°C Discharge Gas Temp. 239°F 115°C Motor Wire Temp. 266°F 130°C
Electrical Components
Overload Protector 7100036 or 7100523 Texas Instrument part # MRA 98545 or MRA 98967 Run Capacitor 15 µF/370 VAC
Performance Data @230V
Based on: Return gas Temp. 95°F 35.0°C Liquid sub-cooling 15°F 8.3°C Ambient 95°F 35.0°C
F°001F°011F°021F°031F°041
o
C3.34oC9.84oC4.45oC06oC
8.73
.PMET.PAVE
F°53
o
C
7.1
rh/utB00370386043652850925
sttaW664135295156707
serepmA1.24.27.29.22.3
.PMET.DNOC
1
Evaporating Temp. 45°F 7.2°C
F°54
o
C
2.7
rh/utB58780728527706175656
sttaW554725765566137
serepmA1.24.27.20.33.3
Condensing Temp. 130°F 54.4°C Return Gas Temp. 95°F 35.0°C Liquid Temp. 115°F 46.1°C Ambient Temp. 95°F 35.0°C
UL file no.: SA4615; CSA file no.: LR46130, LR51349, LR66348, LR76919, LR95789, LR109092
F°55
o
C
8.21
rh/utB574010199013908685108
sttaW534515395176747
serepmA0.24.27.20.34.3
2
Contact Panasonic for value.
2R11S3R236A-6A
208/230 V, 60 H z R-22
BTU 7,000
WIRING DIAGRAM
COMPRESSOR ACCESSORIES
ALTL
502512
)70.8()64.8(
seirosseccArebmuNtraP
1revoClanimreT-teksaGU0260707
2nwoddlohPLO-gnirpS0021407
3revoClanimreTU2220707
4tuN-teksaGU1260707
5revoClanimreT-tuN0030807
temmorG7180707
COMPRESSOR MOUNTING
This document sets forth certain operational parameters and conditions for operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assumes sole and full responsibility and shall indemnify seller with respect to all product failures, and all consequences thereof. Operation of the product outside of the parameters and conditions specified herein shall serve to invalidate all seller warranties, if any, with respect to the product. Use this document as reference only. For specifications, please contact Panasonics engineering department.