Panamax M5100-PM Specifications

Page 1
LOOKING FOR CRYSTAL CLEAR PICTURE AND SOUND?
Clean Power Level 3
Improves picture and sound quality by elimi­nating noise across the entire AC bandwidth.
60% more efficient at eliminating noise than
5100-PM
®
single stage linear filtration (Level 2).
3 Isolated Outlet Banks
Isolating outlet banks from one another prevents noise contamination between components.
High Current Outlets
2 outlets for equipment with high power demands (Amps/Subwoofers).
USB Charger
Convenience charger for mp3 players, cell phones, and other small electronics.
Gaming LAN Port
Easy access to LAN port on front panel. Perfect for online gaming.
Digital Volt Meter
Monitor the voltage supplying your home theater equipment.
12 Volt Trigger
Allows source equipment to activate or deactivate the outlets on the M5100-PM.
Power Sequencing
Guards against blown fuses and potentially damaging speaker thump by automatically powering outlets on and off in sequence.
11 Outlets
5 Always On, 4 Switched, 2 Switched High Current.
AVM (Automatic Voltage Monitoring)
Protects equipment against prolonged over/ under voltages by disconnecting the power and reconnecting it when safe power returns.
M5100-PM
HOME THEATER POWER MANAGEMENT
Improves Picture and Sound Quality
1
Level 3 Power Cleaning and Linear Filtration
(including loss of detail, pops, hisses, hums and visual
artifacts) and allows your A/V equipment to perform up
to its full capability.
Monitors Incoming Line Voltage and Provides a
2
Visual Indication of Power Level
Panamax’s patent pending AVM™ circuitry
continuously monitors the incoming power as displayed on the
digital voltmeter. In case of an undervoltage or an overvoltage, a
flashing lightning bolt will be displayed in red in the voltmeter, and
power to the connected equipment is automatically turned off if
either of these conditions is detected. When voltage returns to a
safe level, power to the equipment is automatically reconnected.
Reduces Cross-Contamination Between Components
3
The M5100-PM is designed to provide noise isolation
between 3 isolated outlet banks including 2 high current
outlets so that any noise created by an A/V component
can not contaminate the power going to equipment
plugged into another outlet bank.
MAX
Three Year Product
Warranty*
$5,000,000 Limited
Connected Equipment Policy*
Product Upgrade Program*
* See actual warranty/policy for details.
www.panamax.com
Page 2
M5100-PM BACK PANEL FEATURES
1. Circuit Breaker:
Automatically opens when the current load is greater than 15 Amps. Push to reset.
2. Outlet Bank 3
Two switched, high-current outlets controlled by the front panel Power Button or the DC Trigger input. Bank 3 has a 5 second turn on delay and turns off immediately. The High Current outlet provides power from a low impedance noise
filtration circuit that does not limit the current to
your equipment. Its output is noise isolated from all other outlet banks.
3. Outlet Bank 2
Four isolated, switched outlets with linear filtration
technology (LiFT) controlled by the front panel Power Button or the DC Trigger input. Bank 2 will turn on immediately and turn off after 10 seconds. LiFT EMI/RFI noise filtration is provided by a two-
stage balanced Pi filter which also provides noise
isolation from Outlet Banks 1 and 3.
4. Outlet Bank 1
Four always-on outlets with linear filtration
technology (LiFT). Power will only be turned off under a fault condition. (See specifications for over-voltage and under-voltage thresholds) Power is cleaned by a two-stage balanced Pi
filter which also provides noise isolation from
Outlet Banks 2 and 3.
5. Universal Coaxial Connectors
3 pairs of bidirectional protection circuits optimized for satellite, cable, and antenna TV signal lines.
6. Main Power
Must be plugged into a properly wired & grounded 3-wire outlet
.
7. Ground Lug:
Provides a common grounding point for equipment with separate ground leads
8. Bank 1 Indicator Light
Normally ON, is lit when there is power present on the Bank 1 receptacles.
M5100-PM SPECIFICATIONS
General________________________________________________________________
Dimensions......................................17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)
Weight........................................................................................................................13.5 lbs.
AC Power_______________________________________________________________
Line Voltage.........................................................................................................120V, 60Hz
Voltage Regulation.............................................................................................................No
Total Current Capacity......................................................................................15 A (1800 W)
Voltage Protection Rating (UL1449 3rd Edition, 3,000A)...............................................500V
Protection Modes.............................................................................................L-N, L-G, N-G
Initial Clamping Level.........................................................................200V Peak, 141V RMS
Energy Dissipation..............................................................................................2125 Joules
Peak Impulse Current........................................................................................60,000 Amps
Catastrophic Surge Circuit................................................................................................Yes
Thermal Fusing:...............................................................................................................Yes
Auto-resetting Over-voltage shutoff...........................................................142 VAC ± 8 VAC
Auto-resetting Under-voltage shutoff...........................................................86 VAC ± 6 VAC
EMI/RFI Noise Filtration___________________________________________________
Bank 1 ............................................................................... Up to -82 db (100 KHz – 2 MHz)
Bank 2 ............................................................................... Up to -80 db (100 KHz – 2 MHz)
Bank 3 ............................................................................... Up to -70 db (100 KHz – 2 MHz)
DC Trigger Input__________________________________________________________
Jacks....................................................................................... 3.5mm (1/8”) mono mini-plug
Voltage and Polarity.........................................................................3 - 24V DC, bidirectional
Current Requirement...................................................................4.6 mA @3V, 58 mA @24V
9. Voltage Sense Trigger Input
3.5mm (1/8”) mono mini-plug. Connect to a remote trigger device that uses a DC output to trigger a startup/shutdown sequence.
LAN Protection__________________________________________________________
Clamping Level.................................................................................................... 60V ± 5V
Compatibility......................................................................................................... 10/100bT
Connectors................................................................................................................RJ-45
Wires Protected:.....................................................................................................8-Wires
USB Circuit______________________________________________________________
Jacks...........................................................................................................................USB-A
Power Delivery.............................................................................................500 mA @5VDC
Telco Protection__________________________________________________________
Fuseless/Auto-resetting....................................................................................................Yes
Clamping Level..............................................................................................................260V
Capacitance.....................................................................................................30pf (approx.)
Suppression Modes...........................................................................Metallic & Longitudinal
Connectors...................................................................................................................RJ-11
Lines Protected.........................................................................................2-Wire, Pins 4 & 5
Universal Coax Protection_________________________________________________
HD 1080 i/p Ready...........................................................................................................Yes
Bidirectional......................................................................................................................Yes
Shielded...........................................................................................................................Yes
Clamping Level................................................................................................................75V
Frequency Range.........................................................................................0MHz - 2.2 GHz
Insertion Loss...........................................................................................................< 0.5 dB
Connectors......................................................................................Female “F”, Gold Plated
Design and specifications subject to change without notice due to product improvement.
10. LAN Jacks
Protection circuits for 10/100 baseT Ethernet lines. Incoming LAN line MUST be plugged into the LINE jack. Patch cord to the equipment MUST be plugged into the EQUIP jacks. 1 LAN jack goes to the front panel output jack. 8 wire protection, 50V clamping.
11. Phone Jacks
Protection circuits for standard telephone or pay-per-view lines. Phone circuit is autoresetting. Incoming phone cord MUST be plugged into the LINE jack. Patch cords to the equipment (satellite receiver, digital video recorder, telephone, etc.) MUST be plugged into the EQUIP jacks.
UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
MODEL M5100-PM
Dimensions Weight Dimensions Weight UPC Qty Dimensions Weight UPC
17” x 12.75” x 3.5” 13.5 lbs 23.25” x 19” x 9.25” 18 Lbs 0 50616 00817 4 1 23.75” x 19.75” x 10” 19 Lbs 5 00 50616 00817 9
4.1” H with feet
1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 • 707-283-5900 • Fax 707-283-5901 • www.panamax.com
© 2009 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax
UNIT CARTON
MASTER CARTON
L587 REV. D 12/09