Palsonic AAC90CW Owners Manual

ROOM AIR CONDITIONER
OWNER'S MANUAL
How to use ..................... P.1~P.6
Installation Instruction .... P.7~P.10
AIRMASTER
1 JOYNTON AVENUE
TEL: (02) 9313 7111
FAX: (02) 9313 7555
www.palsonic.com.au
AIRMASTER CUSTOMER SERVICE
TELEPHONE
AUSTRALIA: 1300 657 888
Thank you for purchasing our air-conditioner. Please read this owner's manual carefully before using your air conditioner.
How to Use
NAMES OF THE PARTS
Front Cover
Air inlet grille (Indoor)
Cabinet Air outlet grille
(Indoor)
Air inlet grille (Outdoor)
Vent Lever Control Panel
(Show in page 4)
Cover Control Panel (behind panel cover)
Spice box
(Used in some type of air conditioner)
Air filter
Fig: 1
NOTE
In quiet operations or stopping the operation, the following phenomena may occasionally occur, but this is normal for operation. (1) Slight flowing noise of refrigerant in the refrigerating cycle (2) Slight rubbing noise from fan casing which is cooled and then gradually warmed as operation stops.
1
The panel of
7000~9000Btu/h
CONTROLS NAMES
Cooler
HIGH COOL OFF
LOW COOL
SELECTOR THERMOSTAT
WAIT FOR THREE MINUTES BEFORE RESTARTING
LOW FAN
HIGH FAN
ON/OFF
The panel of
12000Btu/h
ON/OFF
Cooler
HIGH FAN
OFF
LOW FAN
HIGH COOL
LOW COOL
THERMOSTAT SELECTOR
WAIT FOR THREE MINUTES BEFORE RESTARTING
Fig. 2
The panel of
18000~24000Btu/h
ON/OFF
THERMOSTAT SELECTOR
Cooler
HIGH COOL
MID
COOL LOW COOL
WAIT FOR THREE MINUTES BEFORE RESTARTING
HIGH FAN
MID FAN
LOW FAN
OPERATION AIR DEFLECTORS
Vertical Air Deflectors When the auto louder switch is turned to "ON" position, the vertical air deflectors automatically move right and left, and sweep the jet of air alternately. The vertical air deflectors may be stopped at any position when the auto louder switch is turned "OFF" Horizontal Air Deflectors The horizontal air deflectors can be adjusted.
CAUTION
The shape and position of the switches and indicators may vary from different, but their function are similar.
2
THERMOSTAT
The temperature gets lower from 1 to 5 is for cooling function.
CAUTION
The compressor operates continuously by setting the temperature dial to nearly "TEST". Do not set this dial to the setting as it is for testing purpose. When the compressor stops by turning the temperature dial in cooling operation, wait 3 minutes before turning it back to restart the compressor. Immediate returning the dial may cause overload to the machine, resulting in a blown fuse.
FUNCTION SELECTION
The function selection knob controls fan speed or cooling speed. "HIGH FAN" high speed wind flows out (compressor stopped) "MID FAN" mid speed wind flows out (compressor stopped). (only 18000Btu/h) "LOW FAN" low speed wind flows out (compressor stopped). "HIGH COOL" the fastest cooling is achieved. "MID COOL" the faster cooling is achieved. (only 18000Btu/h) "LOW COOL" slow cooling is achieved. "OFF" the conditioner stop.
CAUTION
Slowly turn the knob from "LOW COOL" to "HIGH COOL" do not turn it too often.
HOW TO EXHAUST ROOM AIR
Turn the lever "CLOSE" to exhaust a portion of the room air. Turn the lever "OPEN" to close vent.
CAUTION
Usually this lever is kept at "CLOSE" position (left). Turn the lever "CLOSE" to close ventilation in case of typhoon.
3