Thank you for purchasing a Paloma/Rheem Convection Gas Space Heater
1. To operate and maintain this appliance safely and correctly, please read these instructions
thoroughly.
2. This appliance must be installed in accordance with:
a. Local Gas Fitting Regulations
b. Municipal Building Codes
c. Australian Standard for Gas Appliance Installations AS/NZS5601.1:-2010
d. Any other relevant Statutory Regulation
e. Manufacturer’s installation instructions
3. This appliance must be serviced by a qualified person.
4. Room heater application: This unflued gas portable convection heater is designed for use in a
single family domestic dwelling for the purpose of room heating. Its use in an application other
Service & Spare Parts................................................................................................................................28
(3) Replace access panel and gently push
into position.
ON
OFF
ON / OFF
BUTTON
OVER-RIDE
BUTTON
OVER
RIDE
5
Features
• AS4553 Efficiency Star Rating of 5.9 Stars.
• One touch ON / OFF button.
• Electronic ign ition.
• Adjustable room temperature - you can adjust the room temperature by pressing the up and down
arrows on the control panel.
• Dual timers – the heater can be set to operate automatically at two separate periods of the day.
• Remote control operation – ON / OFF, temperature control (up/down), timer 1 & 2, override.
• Child lock function prevents accidental operation as well as children interfering with the controls.
• Automatic Economy function – when the room reaches the required temperature the heater
automatically decreases room temperature by 1 deg C for every 30 minutes up to 2 deg C.
•Preheat f unction allows the heater to automatically operate o ne hour prior to the progr ammed starting
time.
• Override function allows the user to manually override the preset program and operate the heater.
• Low Emission Technology – Class 1 Appliance AS4553:2008. Less than half the emissions of the
Australian Standard.
• Energy efficient 7 stage modulating gas valve.
• Manufactured in Japan.
Safety Devices
•Filter Clean W arning Device - W hen the air filter is clogged or hot-air out let is blocked, the filter safet y
device will switch off the heater and the filter light will flash.
• Anti-tilt Safety Switch automatically shuts off gas flow if the heater is knocked or bumped.
• Oxygen Depl etion Safety System autom atically shuts off gas flow if the oxygen level in the room dr ops
below a safe level.
• Flame Failure Device prevents flow of gas to burner if ignition fails or flame goes out.
• Power Failure Device prevents flow of gas to burner if there is a power failure.
• Overheat Safet y Device – if the fan s tops rotating for any reason the overhea t switch shuts off the gas
supply.
• Over Current Safety System.
• Back Burner Protection.
• Unattended Appliance Shut Off Device – the heater shuts off after 8 hours continuous operation.
• Air Volume and Combustion Control.
6
MODEL
PJC-W25FR, PJC-S 25FR , PJC-C25FR
RAC-W25FR, RAC-S25FR, RAC-C25FR
PJC-W18FR, P JC-S 18FR
Sp ace Heater Typ eConvect ion Heater Convect ion Heater
High (MJ/h)2518
Low (MJ/h)99
High (MJ/h)2318
Low (MJ/h)8.28.2
Output (kW)6.14.7
A S 4553 Efficien cy Star Rat in g5.95.9
A S 4553 An nu al Energy
Consumption
67905596
A S 4553 Emission S t ar Ratin g - NG3.94.4
A S 4553 NO 2 Emmissi on
Performance (ng/J) - NG
2.081.65
A S 4553 Emission S t ar Ratin g - LPG3.63.6
A S 4553 NO 2 Emmissi on
Performance (ng/J) - LPG
2.362.44
Approx. Heating Capacity Maximum (Sq.m)
9770
Minimum Room Sizing (Cu.M)62.545
NG (kPa)0.860.47
LPG (kPa)2.01.2
NG (kPa)0.130.13
LPG (kPa)0.30.3
N G (mm)2.42.4
LPG (mm)1.451.45
Number of Injectors11
Temperature Settings16⁰C to 26⁰C16⁰C to 26⁰C
IgnitionContinuous Direct S par kContinuous Direct S par k
Hose Connections (mm)Φ 9.5Φ 9.5
G as Hose Length (M)3.01.5
Electricity Consumption (high/low)31/1827/18
El ect ri cal Co rd l engt h3.01.5
Electrical Supply240V/50Hz/1Phase240V/50Hz/1Phase
Standby Electrical Consumption
(watts)
11
ColoursOff W hite, S ilver & CharcoalOff White
Heater WEIGHT (KGS)13.113.1
H eat er External Dimensi on s
HxWxD
494 x 531 x 242494 x 531 x 242
G as Input - NG
G as Input - LPG
Test P oint P ressure
Test Point Pressure at Turndown
Inj ector Sizes
Specifications
7
Preparation
EXTERNAL DIMENSIONS (mm)
(1) Remove heater from carton.
(2) Please ensure that the gas specified on the rating plate matches your gas supply.
WARNING:
Using a different type of gas may cause an explosive ignition r esulting in injury, damage to heater or
malfunction of the oxygen depletion safety system. Do not install heater if it is the wrong gas type.
Please contact your place of purchase immediately.
(3) Check room s izing – refer spec ifications. Do not install if the actual room size is less than the specified
minimum room size requirements as the heater may s hut down due to oxygen depletion (show ing Error
Code 12 refer page 24).
(4) A dedicated 240V Earthed 10 Amp power point must be used with this heater.
Notice to Victorian Customers: This appliance mus t be installed by a licensed person as required by the
Victorian Building Act 1993. Only a licensed pers on will give you a com pliance certificate showing t hat the
work complies with all relevant standards. Only a licensed person will have insurance protecting their
workmanship for 6 years. Make sure you use a licensed person to install this heater and ask for a
compliance certificate. – Message from the Victorian Plumbing Commission.
8
Danger
Safety Instructions
To ensure safe and proper use of this heater, please read these instructions carefully.
Danger – Indicates an immensely hazardous situation which, if not avoided, will result in serious
injury or death in the most extreme situations.
Warning – Indicates a potentially hazardous situation which, if not avoided, could result in serious
injury or death in the most extreme situations.
Caution – indicates a potentially hazardous situation which, if not avoided, may result in minor
injury.
If a gas leak is detected:
• Do not turn power switches on or off.
• Do not plug or unplug electrical appliances.
• Do not use the telephone.
Flame or sparks may ignite the gas and cause a fire:
• Cease operation immediately by closing the gas valve.
• Open windows and doors for ventilation.
• Contact your gas supplier, a licensed plumber or Rheem Service on 131 031.