SPECIFICATIONS (Approx.)
Model PH-28RIFSN (NAT)
PH-28RIFSP (L.P.)
PH-28CIFSN (NAT)
PH-28CIFSP (L.P.)
PH-28ROFN (NAT)
PH-28ROFP (L.P.)
PH-28COFN (NAT)
PH-28COFP (L.P.)
PH-28RDVSN (NAT)
PH-28RDVSP (L.P.)
PH-28CDVSN (NAT)
PH-28CDVSP (L.P.)
Purpose Domestic Hot Water Supply & Circulating
Rated Gas Input
(Btu/Hr.)
19,000 (Min.)
199,900 (Max.)(Modulating)
19,000 (Min.)
199,900 (Max.)(Modulating)
19,000 (Min.)
199,900 (Max.)(Modulating)
Dimensions (in.) 14 7/8 (W) x 25 3/8 (H) x 11 1/8 (D)
Net Weight (lbs.) 65
Installation Indoor W all Mounting Type
Can be vented either horizontally or vertically
Outdoor W all Mounting
Type
Direct Vent Indoor W all
Mounting Type
Can be vented either hori-
zontally or vertically
Working Water Pressure 14 psi ~ 150 psi
Minimum Water Flow 0.66 GPM
Maximum Flow Rate 7.4 GPM at 45ºF Temperature Rise
Gas Connection 3/4” NPT Female (w/supplied Gas Shutoff Valve)
Water Connection 3/4” NPT Male
Vent Size 4” Special Venting
(Category III)
N/A (Outdoor Installation) 4” Special Venting
(Category III)
Max. Vent Length 37.5 Feet Three 90º Elbow N/A (Outdoor Installation) 37.5 Feet Three 90º Elbow
Effi ciency Rating 84%
Energy Factor 0.82
Inlet Gas Pressure
before water heater
Natural Gas: Min. 4.0” w.c. Max. 10.5” w.c.
L.P. Gas: Min. 8.0” w.c. Max. 14.0” w.c. (Do not exceed maximum pressure.)
Hot Water Supply Factory Setting 100ºF
Adjusting Range R:100ºF ~ 120ºF (140ºF); C: 100°F ~ 180°F
Max. Setting Up to 140ºF(R) or 180°F(C)(w/ Main Remote Control &
Dip Switch Adj.)
Electrical Portion Electrical Rating 120VAC/60Hz, Less than 2 Amps
Power Supply Cord 3 Pin Power Supply Cord 10 Feet (Indoor & Direct Vent)
Safety Devices Oxygen Depletion Safety Sensing Burner (Indoor & Direct Vent)
Over Heat Limiter Film Type for Entire Heat Exchanger
Flame Failure Safety Flame Rod Type
Freeze Protection Minus 30ºF (Without Wind-Chill Factor)
Optional Accessory First Bath Remote Control (USC1-117); Second Bath Remote Control (USC2-117)
DUOnex ™ for 2-Unit Manifolding
MIC-180 for Multi-Unit System Controller (2 to 6 units); MICS-180 for Expansion Board
(Up to 20 units); MIC Communication Cables (16, 32 & 65 feet)
High Altitude Adjustment Chips for use at altitudes above 3,280 feet, and up to 9.840 feet
Hot Water Flow Rate and Temperature Rise
Temp. Rise (ºF) 45 50 60 70 80 90 100
Water Flow (GPM) 7.4 6.7 5.6 4.8 4.2 3.7 3.4
- 3 -
Note: Special Venting: The adapter, vent pipe, elbow, vent terminal, etc. Should be UL 1738 Certifi ed Category III Stainless
Steel Venting Material (e.g. AL29-4C). “B” vent is not permitted.
Since we are constantly improving our products, all specifi cations are subject to change without notice.