If the information in these
instructions is not followed
exactly, a fire or explosion
may result, causing death,
personal injury, or property
damage.
For Your Safety!
• Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
To do so may result in an
explosion or fire.
• Installation and service
must be performed by a
qualified installer, service
agency, or the gas supplier.
What to Do If
You Smell Gas
• Do not try to light any
appliance.
• Do not touch any electrical
switch; do not use any
phone in your building.
• Immediately call your gas
supplier from a neighbor’s
phone. Follow the gas
supplier’s instructions.
• If you cannot reach your
gas supplier, call the fire
department.
• Do not return to your home
until authorized by the gas
supplier or fire department.
94% CONDENSING
TANKLESS
WATER HEATER
USE AND CARE MANUAL
With Installation Instructions
for the Installer
Water Heaters for Other Than
Recreational Vehicle Installation Only
Do not destroy manual. Please
read carefully and keep in a
safe place for future reference.
Direct Vent
Models
Rheem/EcoSense
RTGH-95DV*
RTGH-84V*
ECOH200DV*
ECOH160DV*
Paloma/Wai Wela
PHH-32RDV*
PHH-25RDV*
Ruud
RUTGH-95DV*
RUTGH-84DV*
Richmond
RMTGH95DV*
RMTGH84DV*
*All models available for natural gas (N) or
propane gas (P) usage.
Parts Replacement ...........................................69, 70
READ THE SAFETY INFORMATION
Your safety and the safety of others are very
important. There are many important safety
messages in this manual and on your appliance.
Always read and obey all safety messages.
This is the safety alert symbol.
Recognize this symbol as an indication
of Important Safety Information! This
symbol alerts you to potential hazards
that can kill or hurt you and others.
All safety messages will follow the safety
alert symbol and either the word “DANGER,”
“WARNING,” “CAUTION,” or “NOTICE.”
These words mean:
DANGER: An imminently hazardous
situation that will result in death or serious injury.
WARNING: A potentially hazardous
situation that can result in death or serious injury
and/or damage to property.
CAUTION: A potentially hazardous
situation that may result in minor or moderate injury.
NOTICE: Attention is called to observe a
specified procedure or maintain a specific condition.
WARNINGS:
• This water heater is not suitable for use in
manufactured (mobile) homes!
• Improper installation, adjustment, alteration,
service, or maintenance can cause death,
personal injury, or property damage. Refer to
this manual.
READ ALL INSTRUCTIONS
BEFORE USING.
Be sure to read and understand the entire Use and
Care Manual before attempting to install or operate
this water heater. It may save you time and money.
Pay particular attention to the Safety Instructions.
Failure to follow these warnings could result in
death or serious bodily injury. Should you have
problems understanding the instructions in this
manual, or have any questions, STOP and get help
from a qualified service technician or the local gas
utility.
WARNING:
California Proposition 65
This product contains chemicals known to the state
of California to cause cancer, birth defects, or other
reproductive harm.
2
2
IMPORTANT SAFETY INFORMATION
Water Heater Venting Safety
DANGER: Failure to install and properly
vent the water heater to the outdoors as outlined in
the “Venting” section of the Installation Instructions in
this manual will result in death from fire, explosion, or
asphyxiation from carbon monoxide. NEVER operate
this water heater unless it is properly vented and has
an adequate air supply for proper operation.
Be sure to inspect the vent terminal, the air intake,
and the vent system on the water heater for proper
installation at initial start-up and at least annually
thereafter. Refer to the “Care and Cleaning” section
of this manual for more information regarding vent
system inspection.
WARNINGS:
• Gasoline and other flammable liquids, materials,
and vapors (including paint thinners, solvents,
and adhesives) are extremely dangerous. DO NOT
handle, use, or store gasoline or other flammable or
combustible materials anywhere in the vicinity of a
water heater or any other appliance. Be sure to read
and follow the labels on the water heater, as well
as the warnings printed in this manual. Failure to
do so can result in death, bodily injury, or property
damage.
• Combustible construction refers to adjacent walls
and ceilings and should not be confused with
combustible or flammable products and materials.
Combustible materials, such as clothing, cleaning
materials, or flammable liquids, should never be
stored in the vicinity of this or any gas appliance.
Fire or explosion can occur causing death, personal
injury, and/or product damage. See page 29 for
clearances to combustible materials.
• Follow vent manufacturer’s instructions for venting
installation, including additional clearances from
combustibles, to avoid conditions that can lead to
death, personal injury, and/or property damage.
• Use tankless water heater manufacturer-approved
Schedule 40 PVC (foam core is not permitted at any
time), Schedule 80 PVC, CPVC, ABS, polypropylene,
or UL 1738-listed Category III Stainless Steel. No
other vent material is permitted.
• Moisture in the flue gas will condense as it leaves
the vent terminal. In cold weather this condensate
can freeze on the exterior wall, under the eaves, and
on surrounding objects. Some discoloration to the
exterior of the building is to be expected. However,
improper location or installation can result in severe
damage to the structure or exterior finish of the
building.
D A N G E R
FLAMMABLES
Vapors from flammable
liquids will explode and
catch fire causing death or
severe burns.
Do not use o r sto re flammable
products s uch a s gas olin e,
solvents o r adh esiv es in the
same room o r are a near the
water heat er.
Keep flamm able prod ucts :
1. far away from heater,
2. in a ppro ved c ontainers,
3. tig htly clos ed and
4. out of ch ildren's reach.
Installation:
Do not inst all water heater
where flam mabl e pro du
be stored o r use d unless the
main b urne r fla me is at lea st
Read and follow water heater warnings and instructions. If
owners manual is missing, contact the retailer or manufacturer.
• For multiple-unit installation, a minimum distance
between vent terminations must be maintained to
prevent recirculation of vent gases. See page 39 for
information on venting and clearances to multiple
terminations.
Flam mab le Vap ors
Water h eate r has a main
burner fla me.
The main bu rner flame:
1. whi ch ca n com e on
at an y tim e and
2. wil l ign ite flammable
vapo rs.
Vapors:
1. can not b e see n,
2. are heav ier t han air,
3. go a long way on the
floo r and
4. can be carri ed fro m
other r ooms t o the
main bu rner f lame b y
air cur rent s.
18" above t he fl oor. This will
cts wi ll
reduce, bu t not eliminate, the
risk o f vap ors b eing ignited
by the main burn er flame.
CAUTIONS:
• Ensure that the appliance vent is securely glued and
attached to the vent connection on the top of the
water heater. DO NOT USE SCREWS.
• Do not operate without the condensate drain
connected and routed to the proper drain.
Safety
3
3
IMPORTANT SAFETY INFORMATION
Water Supply Safety
DANGERS:
• WATER TEMPERATURE
Safety
SETTINGS – Safety and energy
conservation are factors to be
considered when selecting the
water temperature setting of a
water heater’s remote control.
Water temperatures above 125°F
(52°C) can cause death or severe
burns from scalding. Be sure to
read and follow the warnings
outlined on the pictured label.
• There is a hot water scald potential
if the water temperature is set
too high. Households with small
children, the disabled, or elderly
persons may require a 120°F
(49°C) or lower temperature setting
to prevent contact with “HOT”
water.
• Before manually operating the relief
valve, make certain no one will be
exposed to the danger of the hot
water released by the valve. The
water may be hot enough to create
a scald hazard. The water should
be released into a suitable drain to
prevent injury or property damage.
• Failure to perform the recom-
•mended Routine Preventive Maintenance can harm
the proper operation of this water heater, which can
cause carbon monoxide dangers, excessive hot
water temperatures, and other potentially hazardous
conditions.
WARNINGS:
• IMPORTANT: Do not apply heat to the HOT or
COLD water connections. If sweat connections are
used, sweat tubing to adapter before fitting adapter
to the water connections on heater. Any heat
applied to the water supply fittings will permanently
damage the internal components of the water
heater.
• In case the pipe insulation is not rated for the
appropriate weather conditions, install electric
heat tracing or equivalent to prevent freezing of
the pipes. Do not insulate or block the drain valve
on the hot outlet fitting. If the pipes are allowed
to freeze, the water heater and the pipes may
malfunction or leak due to freezing water.
• Failure to drain the water heater as described on
page 20 can cause serious personal injuries from
scalding and/or damage the water heater.
!
D A N G E R
HOT
BU RN
Water temperature over 125°F (52°C)
can cause severe burns instantly or
death from scalds.
Children, disabled and elderly are
at highest risk of being scalded.
See instruction manual before
setting temperature at water
heater.
Feel water before bathing or
showering.
Temperature limiting valves are
available, see manual.
Time/Temperature
Relationship in Scalds
Water Temperature Time to Produce
a Serious Burn
120°F (49°C) More than 5 minutes125°F (52°C) 1 1/2 to 2 minutes
130°F (54°C) About 30 seconds
135°F (57°C) About 10 seconds
140°F (60°C) Less than 5 seconds
145°F (63°C) Less than 3 seconds
150°F (66°C) About 1 1/2 seconds
155°F (68°C) About 1 second
with the following water supply system
conditions:
– With clean, potable water free of
corrosive chemicals, sand, dirt, or
other contaminants.
– With inlet water temperatures above
32°F (0°C), but not exceeding 120°F
(49°C).
– DO NOT reverse the hot and cold
water connections. The water heater
will not operate.
•
Even when drained properly, a small
amount of water will remain in the water
heater. In cold weather conditions, this
water can freeze. If this happens, allow the
defrost protection on the heater at least
30 minutes to melt the frozen water or the
water heater may not work properly.
NOTICE:
allows operating temperatures between
100°F (38°C) and 120°F (49°C).
Temperatures of 85°F (29°C) and up
to 140°F (60°C) can be achieved with
the MAIN (UMC-117) remote control.
Temperatures of 85°F (29°C) can be
achieved with the Bath (USC-117 or
USC2-117) remote control. Only qualified
service personnel should perform this
adjustment. Only factory-authorized
remote control(s) should be used.
The factory setting
4
IMPORTANT SAFETY INFORMATION
Natural Gas and Liqueed Petroleum Safety
DANGERS:
• Never attempt to convert the water heater from
natural gas to LP. The water heater should only
use the fuel type in accordance with listing on data
plate—natural gas for natural gas units and LP for
LP units. Any other fuel usage will result in death or
serious personal injury from fire and/or explosion.
This water heater is not certified for any other fuel
type.
• Both natural gas and propane (LP) have an odorant
added to aid in detecting a gas leak. Some people
may not physically be able to smell or recognize
this odorant. If you are unsure or unfamiliar with
the smell of natural gas or LP, ask the gas supplier.
Other conditions, such as “odorant fade,” which
causes the odorant to diminish in intensity, can also
hide or camouflage a gas leak.
• Water heaters using LP gas are different from
natural gas models. A natural gas water heater will
not function safely on LP and vice versa.
• LP water heaters should not be installed below
grade (for example, in a basement) if such
installation is prohibited by federal, state, and/or
local laws, rules, regulations, or customs.
• LP must be used with great caution. It is heavier
than air and will collect first in lower areas, making it
hard to detect at nose level.
• Before attempting to light the water heater, make
sure to look and smell for gas leaks. Use a soapy
solution to check all gas fittings and connections.
Bubbling at a connection indicates a leak that must
be corrected. When smelling to detect a gas leak,
be sure to also sniff near the floor.
• Gas detectors are recommended in LP and natural
gas applications and their installation should be
in accordance with the detector manufacturer’s
recommendations and/or local laws, rules,
regulations, or customs.
• Combustible materials, such as clothing, cleaning
materials, or flammable liquids, must not be placed
in the vicinity of the water heater.
• If a gas leak is present or suspected:
– Do not attempt to find the cause yourself.
– Never use an open flame to test for gas leaks. The
gas can ignite resulting in death, personal injury,
or property damage.
– Follow the steps listed under “What to Do If
You Smell Gas” found on the front cover of this
manual.
WARNINGS:
•The installation of gas piping must conform to local
utility company requirements and/or in the absence
of local codes, use the latest edition of National Fuel
Gas Code (NFGC), ANSI Z223.1/NFPA 54, or CSA
B149.1, Natural Gas and Propane Installation Code.
• Install a gas pressure regulator in the gas supply
line. The regulator should not exceed the maximum
supply pressure. DO NOT use an industrial-type gas
regulator.
• Should overheating occur or the gas supply fail to
shut off, turn off the manual gas control valve to the
water heater.
CAUTIONS:
• Do not attempt repair of electrical wiring, gas piping,
remote control, burners, vent connectors, or other
safety devices. Refer repairs to qualified service
personnel.
• Turn off the manual gas shut-off valve if the water
heater has been subjected to overheating, fire,
flood, physical damage, or if the gas supply fails
to shut off.
• Do not turn on the water heater unless the water
and gas supplies are completely opened.
Safety
5
IMPORTANT SAFETY INFORMATION
Before operating this water heater, be sure to read
and follow the instructions on the label pictured
below and all other labels on the water heater,
as well as the warnings printed in this manual.
Failure to do so can result in unsafe operation
of the water heater, resulting in death, personal
Safety
injury, or property damage. Should you have any
problems reading or following the instructions in
this manual, STOP and get help from a qualified
service technician.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING : If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
1.STOP! Read the safety information above on this label.
2.Turn off all electric power to the appliance.
3.Do not attempt to light the burner by hand.
4.Turn the Gas Shutoff Valve located on the outside of the unit
clockwise to the "OFF" position.
5.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in
the safety information above on this label. If you don't smell gas, go to the next step.
6.Turn the Gas Shutoff Valve located on the outside of the unit counterclockwise to
the "ON" position.
7.Turn on all electric power to the appliance.
8.If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance"
and call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1.Turn off all electric power to the appliance if service is to be performed.
2.Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the "OFF" position.
6
OPERATING INSTRUCTIONS
GAS SHUTOFF
VALVE
OPENCLOSE
Electrical Safety
IMPORTANT SAFETY INFORMATION
DANGER:Shock Hazard – Make sure
the electrical power to the water heater is off to avoid
electric shock that will result in death or serious
personal injury.
WARNINGS:
• For your safety, the information in this manual must
be followed to minimize the risk of fire, explosion,
or electric shock that can result in death, personal
injury, and/or property damage.
• Field wiring connections and electrical grounding
must comply with local codes or, in the absence of
local codes, with the latest edition of the National
Electrical Code, ANSI/NFPA 70, or in Canada,
Canadian Electrical Code, CSA C22.1, Part 1.
CAUTIONS:
• Label all wires prior to disconnecting for service.
Wiring errors can cause dangerous and improper
operation. Verify correct operation after servicing.
• For your safety, burner inspection and cleaning
should be performed only by qualified service
personnel.
• Make certain the power to the water heater is OFF
before removing the unit cover panel. Exposed
electrical components and moving parts can cause
personal injuries.
• For your safety, DO NOT attempt repair of electrical
wiring, gas piping, remote control, burners, vent
connectors, or other safety devices. Refer repairs to
qualified service personnel.
FOR INSTALLATIONS IN THE STATE OF CALIFORNIA
California law requires that water heaters must
be braced, anchored, or strapped to resist falling
or horizontal displacement due to earthquake
motions. For water heaters up to 52-gallon
capacity, a brochure with generic earthquake
bracing instructions can be obtained from: Office
of the State Architect, 1102 Q Street, Suite 5100,
Sacramento, CA 95814, or you may call
916-445-8100 or ask a water heater dealer.
However, applicable local codes shall govern
installation. For residential water heaters of a
capacity greater than 52 gallons or tankless-style,
consult the local building jurisdiction code for
acceptable bracing procedures.
Safety
7
IMPORTANT SAFETY INFORMATION
General Installation and Maintenance Safety
WARNINGS:
•This water heater must be installed in accordance
with these instructions, local codes, utility
company requirements and/or in the absence of
local codes, use the latest edition of the American
National Standard/National Fuel Gas Code
(NFGC), ANSI Z223.1 and National Fire Protection
Association, NFPA 54, or in Canada, CSA B149.1,
Natural Gas and Propane Installation Code, and
the latest edition of the National Electrical Code,
ANSI/NFPA 70, or in Canada, Canadian Electrical
Code, CSA C22.1, Part 1.
• If local codes require the application of external
insulation blanket kits, carefully follow the
manufacturer’s installation instructions included
Product InformationSafety
with the kit. Only use blanket kits that are
approved for use with your water heater.
• For your safety, DO NOT attempt to disassemble
this water heater for any reason. Improper
adjustments, alterations, service, or maintenance
can cause death, personal injury, or property
damage.
SAFETY PRECAUTIONS:
• Read this manual entirely before installing and/or
operating the water heater.
• Use this water heater only for its intended purpose
as described in this Use and Care Manual.
• Have the installer show you the location of the gas
shut-off valve and how to shut it off if necessary.
Turn off the manual shut-off valve if the water heater
has been subjected to overheating, fire, flood,
physical damage, or if the gas supply fails to
shut off.
• Be sure your water heater is properly installed in
accordance with local codes and the provided
installation instructions.
• Do not attempt to repair or replace any part of your
water heater unless it is specifically recommended
in this manual. All other servicing should be referred
to a qualified service technician.
SAVE THESE
INSTRUCTIONS
PRODUCT INFORMATION
For Your Records
Write down and save the following product
information along with the original sales slip and/or
cancelled check. The model and serial numbers
can be found on the top label on the right side of
the water heater.
MODEL NUMBER:
SERIAL NUMBER:
DATE OF INSTALLATION:
INSTALLING COMPANY/PHONE NUMBER:
PLUMBING CONTRACTOR/PHONE NUMBER:
Read This Manual
Inside you will find many helpful hints on how to use and
maintain your water heater properly. A little preventive
care on your part can save you time and money over the
life of your water heater.
You’ll find many answers to common problems in the
Troubleshooting Chart on pages 23 and 24. Always refer
to this chart before calling for service. Referring to this
chart before calling may answer your question(s) and
eliminate the need for service.
Preoperating Checklist
Is the main gas valve to the water heater turned on?
Does the water heater have its own circuit breaker
or fuse?
Does the water heater’s electronic ignition light?
Is the water temperature set to a safe temperature?
Is the water heater connected to a floor drain?
Is the water heater properly vented to the outside?
See page 26 for additional service information.
8
Is the water heater installed in a safe location away
from flammable materials and/or freezing conditions?
Overheat Film Wrap, Flame Rod, Water Temperature High-Limit
Switch, Flue Temperature High-Limit Switch
Remote Control, Service Valves, Vent Kits, Pipe Cover, EZ Link, MIC-6,
3.1
MIC-185, Recess Box**
RTGH-95DV* and RTGH-95X*
ECOH200DV* and ECOH200X*
PHH-32RDV* and PHH-32ROF*
RUTGH-95DV* and RUTGH-95X*
RMTGH95DV* and RMTGH95X*
3.9 Indoor
4.2 Outdoor
4.6 Indoor
4.7 Outdoor
*N or NG = natural gas and P or LP = liquefied petroleum
** = Outdoor Only
10
General Descriptions
PRODUCT INFORMATION
Typical Direct-Vent Water Heater
(Venting Required)
Remote Control
With Power Switch
Product Information
To Hot Water
Faucet(s)
Condensate
Drain Valve
Pipe*
Power
Supply
Cord
Union
To Suitable
Drain
Water
Filter
Service
Valve
Relief
Relief
Valve
Valve
Union
Cold Water Supply
Shut-Off Valve
To Suitable
Drain
*Note: A flexible drain tube can be used
Manual Gas
Shut-Off Valve
Sediment Trap
Cap
Manual Gas
Supply Line
Shut-Off Valve
11
PRODUCT INFORMATION
Typical Outdoor Water Heater
(No Venting Required)
This water heater is for OUTDOOR installation only.
DANGER: DO NOT install this water heater indoors or in an enclosure. It is designed for
outdoor installation only. Any other type of installation will result in death or serious personal injury.
Flue
Terminal
Product Information
To Hot Water
Faucet(s)
Condensate
Hard-Wire
Pipe*
Power Supply
Cord
(not supplied)
Union
Air Inlet
Service
Relief
Relief
Valve
Valve
Valve
Water
Filter
Manual Gas
Shut-Off Valve
Union
Remote Control
With Power Switch
Manual Gas
Supply Line
Shut-Off Valve
Drain Valve
12
To Suitable
Drain
Cold Water Supply
Shut-Off Valve
To Suitable
Drain
*Note: A flexible drain tube can be used
Sediment Trap
Cap
Safety Precautions
USING YOUR WATER HEATER
WARNING: Flammable vapors can
be drawn by air currents from surrounding areas to
the water heater. Vapors can ignite causing death,
personal injury, or product damage.
• DO NOT store or use flammable or combustible
materials (gasoline, paint thinner, adhesives,
newspapers, rags, mops, etc.) in the vicinity of
the water heater or any other gas appliance. If
they must be used, open doors and windows
for ventilation, and shut off all gas-burning
appliances, including their pilot lights.
• DO turn off manual gas shut-off valve if water
heater has been subjected to overheating, fire,
flood, physical damage, or if the gas supply fails
to shut off.
• DO NOT turn on water heater unless water and
gas supplies are completely opened.
• DO NOT turn on water heater if cold water
supply shut-off valve is closed.
• If there is any difficulty in understanding or
following the operating and care instructions in
this manual, it is recommended that you contact
a qualified service technician to perform the work.
Setting the Water Temperature
DANGER: Water temperatures above 125°F (52°C)
will result in death and/or severe burns from scalding.
Safety and energy conservation are factors to be considered
when selecting the water temperature setting. The temperature
of the water in the water heater can be regulated by setting the
temperature on the front of the remote control. Be sure to read
and follow the warnings outlined on the pictured label.
!
D A N G E R
Use Instructions
The recommended setting for the water temperature is 100°F
(38°C). The remote control has been preset and shipped at the
recommended temperature setting.
Safety factors should be considered whenever altering the water
temperature setting. The chart below may be used as a guide in
determining the proper water temperature for your home.
Time/Temperature
Relationship in Scalds
Water Temperature Time to Produce a Serious Burn
120°F (49°C) More than 5 minutes125°F (52°C) 1 1/2 to 2 minutes
130°F (54°C) About 30 seconds
135°F (57°C) About 10 seconds
140°F (60°C) Less than 5 seconds
145°F (63°C) Less than 3 seconds
150°F (66°C) About 1 1/2 seconds
155°F (68°C) About 1 second
Table courtesy of Shriners Burn Institute
HOT
BU RN
Water temperature over 125°F (52°C)
can cause severe burns instantly or
death from scalds.
Children, disabled and elderly are
at highest risk of being scalded.
See instruction manual before
setting temperature at water
heater.
Feel water before bathing or
showering.
Temperature limiting valves are
available, see manual.
13
USING YOUR WATER HEATER
Setting the Water Temperature (cont.)
Use Instructions
Maximum water temperature occurs while the
water heater burner is on. To determine the water
temperature:
Turn on the hot water faucet and place a
thermometer in the water stream.
NOTICE: Water temperature at the faucet
may vary depending on the season and the length
of pipe from the water heater.
The remote control temperature range is between
100°F (38°C) and 120°F (49°C). To adjust the
temperature to a desired setting, press the UP
or DOWN adjustment button on the face of the
remote control. The new temperature set point will
show on the LED display.
In-Use Indicator
(Lit during operation)
Priority
Indicator
Temperature
Adjustment
Buttons
NOTICES:
• The temperature set point on the standard
remote control cannot be increased above
112°F (44°C) when a hot water faucet is in the
open position. To achieve temperatures above
120°F (49°C) or 85°F (29°C), contact a qualified
service technician. Only factory-authorized
remote control(s) should be used.
• The water heater may not operate with a
small water flow. Increase the water flow and
recheck. If it still does not operate with the hot
water faucet completely open, increase the
temperature setting on the remote control.
Water Heater Facts
DANGER: Water temperatures above
125°F (52°C) will result in death and/or severe
burns from scalding.
• The hottest-temperature water will be at the
faucet closest to the water heater.
• Always remember to test the water temperature
with your hand before use.
• Always supervise young children or others who
are incapacitated.
• The water heater is equipped with a device
that will shut off the gas supply to the burner
if the water heater exceeds normal operating
temperatures.
• Any water heater that has been subjected to fire,
flood, physical damage, or been under water
should be turned off at the manual gas shut-off
valve and not used until it has been checked by
qualified service personnel.
LED Temperature
and Error Code
Display
14
Power On/Off
Button and
Indicator
CARING FOR YOUR WATER HEATER
Condensate Drain
Water Heater Inspections
Venting System
(Direct Vent Only)
The venting system should be inspected annually
to ensure all of the vent sections are secure and
airtight. Qualified service personnel are familiar
with vent system inspections.
WARNING: Do not operate the
water heater if the vent system shows signs of
leaking exhaust. Leaking exhaust could lead to
death, personal injury, and/or product failure.
Outdoor models
For outdoor models, check the air intake and
vent outlet for blockage and/or debris.
Condensate Collector
CAUTIONS:
• Condensate is known to be acidic; refer to
federal, state (provincial), and local codes for
proper handling and discharge methods.
• Do not operate without the condensate collector
drain connected and routed to the proper drain.
This could cause the system to malfunction or fail.
Care Instructions
On a regular basis, inspect the condensate drain
line to ensure the condensate is draining properly.
The condensate coming from the water heater is
known to be acidic. The heater features a built-in
condensate neutralizer that uses CaCO3 (calcium
carbonate) in rock form as a medium.
DANGER:Shock Hazard – Make
sure the electrical power to the water heater is off
to avoid electric shock that will result in death or
serious personal injury.
Periodically check the medium visually to ensure
that it is not depleted and refill accordingly. It is
recommended that you contact a qualified service
technician to perform the work.
15
CARING FOR YOUR WATER HEATER
Burner
Sight
Glass
Water Heater Inspections (cont.)
Burner
Visually inspect the main burner annually.
DANGER: Shock Hazard –
Removing the front cover panel exposes you to
live electricity. Electric shock will cause death or
serious personal injury.
1
Remove 6 screws and the unit cover panel.
3
While the water heater is operating, inspect the
main burner flames through the burner sight
glass. The flames should be blue when the main
burner is firing.
NOTICE: If the flames are not blue or
you observe unusual burner operation, shut off
the water heater and contact a qualified service
technician.
Care Instructions
2
Turn on a hot water faucet.
4
Turn off the hot water faucet and reinstall the
unit cover panel.
16
Care and Cleaning
Drain Valve
Cold Water Supply
Shut-Off Valve
CARING FOR YOUR WATER HEATER
DANGER: Shock Hazard – Make
certain power to the water heater is OFF before
removing protective cover for any reason. Electric
shock will cause death or serious personal injury.
WARNING: Combustible materials,
such as clothing, cleaning materials, or flammable
liquids, must not be placed against or next to the
water heater. Fire or explosion can occur causing
death, personal injury, and/or product damage.
All care and cleaning to and around the water
heater should only be performed with the water
heater turned off and the electrical power
supply disconnected.
1
Vacuum around the water heater to remove any
dust, dirt, and/or lint buildup.
NOTICE: The air intake requires a
minimum of 12 in. (30 cm) of clearance between
the air intake opening and any obstruction.
Clean the water filter monthly, as described below.
Water Filter Cleaning
1
Turn off the water heater and disconnect the
electrical power supply.
2
2
Clean the water heater and the remote control
with a damp soft cloth and mild detergent.
Gently wipe and completely dry all surfaces.
Outdoor models
3
Check the air intake and vent outlet for
blockage and/or debris.
Turn off the water supply to the water heater.
Care Instructions
3
Drain the water heater. See page 20.
17
CARING FOR YOUR WATER HEATER
Care and Cleaning (cont.)
CAUTION: Do not tap or force
the filter during removal. This can deform and/or
damage the filter.
4
Unscrew the water filter from the base of the
cold water inlet line and carefully slide it out
of the line.
CAUTION: Do not overtighten the
water filter. Overtightening can deform and/or
damage the filter.
6
Replace the filter in the cold water inlet line and
tighten until it is snug.
Care Instructions
5
Clean the water filter under running water. To
remove severe sediment and dirt, use a soft
brush.
7
Turn on the water supply, reconnect the
electrical supply, and turn on the water heater.
18
Preventive Maintenance
Relief
Valve
WARNING: Failure to perform
routine preventive maintenance can prevent the
water heater from operating properly. Improper
operation can cause carbon monoxide dangers,
excessive water temperatures, and other
potentially hazardous conditions resulting in death,
personal injury, and/or product damage.
Properly maintaining your water heater will ensure
dependable, trouble-free service.
User Preventive Maintenance
Establish and follow a routine preventive
maintenance program. The following suggested
items should be included in your program.
• Monthly check and clean the water filter. See
“Water Filter Cleaning” on page 17.
WARNING: Hot water is released
during manual operation of the relief valve. Make
sure all people and animals are clear from the area
before performing this check to prevent death,
personal injury, and/or property damage from hot
drain water.
CARING FOR YOUR WATER HEATER
NOTICE: If the pressure relief valve on
the hot water heater discharges periodically, this
may indicate a problem in the water system.
Contact the water supplier or a plumbing
contractor to correct the problem. DO NOT
plug the relief valve outlet.
• Inspect and keep the area around the water
heater clear and free of flammable materials,
such as gasoline and other flammable vapors
and liquids.
• Visually inspect the water heater for damage
and/or denting. If present, contact a service
personnel to verify proper operation.
• Check for abnormal sound during normal
operation (e.g., hissing or banging noises).
Contact a qualified service technician or
plumbing contractor.
• Check all gas and water pipes for leaks. See
page 55.
NOTICES:
– DO NOT operate the water heater if you feel
something is wrong with the unit.
– DO NOT allow children to operate or handle
the unit.
• After inspections, maintenance, and/or cleaning,
ensure proper operation by turning on a hot
water faucet.
Care Instructions
• Annually check the operation of the pressurerelief valve. Lifting the lever handle on the
pressure-relief valve opens the valve to flush hot
water through the discharge line to the drain.
After several gallons have drained, release the
lever handle to close the valve and stop draining.
Professional
Preventive Maintenance
It is recommended that a periodic inspection of
the water heater burner, relief valve, air intake filter,
water filter, and venting system be made by a
qualified service technician.
19
CARING FOR YOUR WATER HEATER
Cold Water Supply
Shut-Off Valve
Draining the Water Heater
WARNING: Failure to follow these
draining instructions can cause serious personal
injury from scalding and/or product damage.
1
Turn off the water heater by pressing the
POWER ON/OFF button on the control panel.
2
5
Close the water shut-off valve.
6
Using a suitable container to catch the water,
remove the water filter from the base of the cold
water inlet line.
Care Instructions
Close the gas shut-off valve(s).
3
At least 10 seconds after Step 1, unplug the
water heater or disconnect the power supply at
the circuit breaker box.
4
Open all hot water faucets. Run the water until it
is COLD; then shut off the faucet.
7
Connect a garden hose to the drain valve in the
hot water outlet line and place the other end in
a suitable drain. Open the drain valve until all
the water has drained from the water heater.
Leave water heater as is until placed back in
service.
20
CAUTION: Even when drained
properly, a small amount of water will remain in
the water heater. In cold weather conditions, this
water can freeze. If this happens, allow the defrost
protection on the water heater at least 30 minutes
to melt the frozen water. The water heater will not
work properly until this water is thawed.
To put the water heater back in service:
1
CARING FOR YOUR WATER HEATER
4
Open all hot water faucets and let run until all
air has been purged from the lines.
Disconnect drain hose. Make sure the drain
valve is closed.
2
Reinstall the water filter in the base of the cold
water inlet line.
3
Open the water shut-off valve.
5
Plug in the power cord or reconnect the power
supply at the circuit breaker box.
6
Open the gas shut-off valve(s).
Care Instructions
7
Press the POWER ON/OFF button on the
control panel to restart the unit.
21
CARING FOR YOUR WATER HEATER
Cold Water
Service Valve
Hot Water
Service Valve
Pressure
ReliefValve
Pressure
Relief Valve
Water
Outlet
Water
Outlet
Water
Inlet
Water
Inlet
Drain
Drain
Draining the Water Heater (cont.)
Standard Drain Method
Service isolator valve kits may be purchased from
the manufacturer, distributor, or place of purchase.
The kits include two full-port isolation valves to
be used in the inlet and outlet water lines. These
kits provide a means for full diagnostic testing and
ease of system flushing.
Freeze Protection
Care Instructions
WARNING: Failure to drain the
water heater can cause serious personal injury
from scalding and/or product damage.
Whenever the water heater may be exposed to
freezing conditions, make sure to completely drain
the water from the unit. See page 20.
Freezing conditions come from the ventilation
system on direct-vent models and from exposure
to cold air on outdoor models.
All of these water heaters are equipped with
a freeze protection electric heater. This heater
prevents freezing inside the water heater down to
an ambient temperature of approximately -30°F
(-34°C). These temperatures are all based on
temperatures without wind.
The heater only protects the internal components
of the water heater.
NOTICE: Unplugging or disconnecting
the power supply to the water heater will also
disconnect the power to the heater.
External piping and valves require additional
freeze protection. One method is to wrap
insulation around the piping and valves.
Another method is to turn on a hot water faucet
and leave a small amount of water running at a
faucet. This will protect the water heater, piping,
and valves from freezing.
Running Water Freeze Protection
1
Turn off the water heater by pressing the
POWER ON/OFF button on the control panel.
2
Close the gas shut-off valve(s).
22
3
Open a hot water faucet slightly until the water
stream is approximately 1/8 in. (0.3 cm). Be sure
to check the flow periodically.
CARING FOR YOUR WATER HEATER
Vacation and Extended Shutdown
WARNING: Failure to drain the
water heater can cause serious personal injury
from scalding and/or product damage.
If the water heater is to remain idle for an
extended period of time, the power and water to
the heater should be turned off.
The water heater and piping should be drained if
they might be subjected to freezing temperatures.
See “Freeze Protection” section on page 22.
After an extended shutdown, the water heater’s
operation and controls should be checked by a
qualified service technician.
Troubleshooting Chart
The information in the following troubleshooting
chart may help you diagnose and/or fix a problem
you may be experiencing. Please review this chart
before calling for service assistance.
DANGER: Shock Hazard – Make
certain power to the water heater is OFF before
removing protective cover for any reason. Electric
shock will cause death or serious personal injury.
ProblemPossible CauseSolution
Not enough or no hot water.
1. Unit is not ON. 1. Turn on the unit by pressing the
2. Water shut-off valve is not completely
opened.
3. Hot water faucet is not completely
opened.
4. Water piping is frozen. 4. Allow piping to thaw.
5. Electrical power is disconnected or
water supply is shut off.
6. The temperature may be set too low. 6. Increase the temperature setting.
7. Mixing valve malfunctions (if
applicable).
8. Error code displayed on the remote
control.
9. Not enough water demand. 9. Increase the hot water flow at the
10. Water filter is clogged or dirty.10. Clean the water filter. (See page 17.)
11. Fixture aerator is clogged or dirty.11. Clean the aerator.
12. Scale buildup in the heat exchanger.12. Check for error code. If required,
13. Hot and cold water lines reversed.13. Reverse the water lines.
WARNING: For Your Safety, DO
NOT attempt repair of electrical wiring, gas piping
remote control, burners, vent connectors, or other
safety devices. Refer repairs to a qualified service
technician.
POWER ON/OFF button.
2. Check shut-off valve and open
completely.
3. Open hot water faucet completely.
(The main burner goes off when incoming water volume is inadequate.)
5a. Plug in the power cord or reconnect
the power supply at the circuit
breaker box.
5b. Completely open the water supply
valve. (Inadequate water volume will
cause the main burner to turn off.)
7. Check and replace the mixing valve.
8. See “Service Error Code Chart” on
page 26. If required, contact a
qualified service technician.
faucet.
contact a qualified service technician.
Care Instructions
23
CARING FOR YOUR WATER HEATER
Troubleshooting Chart (cont.)
ProblemPossible CauseSolution
Water not hot enough.
1
1.The temperature may be set too low. 1.Increase the temperature setting at
the remote control.
Water too hot.
3
2.The gas valve is not completely
opened.
2.Check and completely open the gas
valve.
3.Gas supply pressure is low. 3. Contact your gas utility company or
2
4.Bleed-over in one of the hot water
fixtures.
gas contractor to verify the gas meter
and gas piping size.
4.Contact a dealer or a qualified service
technician.
1.Temperature is set too high. 1. Decrease the temperature setting at
the remote control.
1
2.Water shut-off valve is not completely
opened.
3.Small amount of water has been
heated.
2.Check and completely open the water
shut-off valve.
3.Increase the hot water flow at the
faucet to allow more water to flow
through the water heater.
Fan continues to rotate after the hot water
Care Instructions
faucet is closed.
24
2
The post-purge cycle clears flue gases.Normal operation.
CARING FOR YOUR WATER HEATER
Service Error Code Chart
Your water heater has an electronic diagnostic
system built into it. When the water heater finds
a problem, it displays an error code in the LED
display on the remote control. The following chart
lists the error codes along with their possible
problem and solution. Using this chart may help
you diagnose and/or fix a problem you may be
experiencing. Please refer to this chart before
calling for service assistance.
DANGER: Shock Hazard – Make
certain power to the water heater is OFF before
removing protective cover for any reason. Electric
shock will cause death or serious personal injury.
WARNING: For Your Safety, DO
NOT attempt repair of electrical wiring, gas piping,
remote control, burners, vent connectors, or other
safety devices. Refer repairs to a qualified service
technician.
3
Wait about 5 minutes; then restart the water
heater by pressing the POWER ON/OFF button.
4
When an error code is displayed:
1
Turn off all the hot water faucets.
2
Turn off the water heater by pressing the
POWER ON/OFF button on the remote control.
Turn on a hot water faucet and recheck the
remote control display.
If the error code remains in the display:
1. Turn off the hot water faucet.
2. Turn off the water heater.
3. Follow the error code chart information.
4. Restart the water heater, turn on a hot water
faucet, and recheck the remote control display.
If the error code is still shown:
1. Turn off the hot water faucet.
2. Turn off the water heater.
3. Make note of the displayed error code and call
for service assistance. See “Call for Assistance”
section on page 26.
NOTICE: If the displayed error code is not
listed in the chart, immediately turn off the water
heater and call for service assistance.
Care Instructions
25
CARING FOR YOUR WATER HEATER
Service Error Code Chart (cont.)
Error CodePossible CauseSolution
1L
05
11
12
13
14
15
29
31
33
61 or 99
65
92
93
P1
Water heater has buildup of lime deposits.Contact a dealer or qualified service
Air intake or vent exhaust opening may be
blocked.
The vent pipes on the vent termination
may not be connected properly.
The gas shut-off valve is not fully opened.Check shut-off valve and open completely.
Gas service has been interrupted.Contact your gas utility company.
LP gas is running low (LP models only).Refill or replace your LP gas container.
If this code is still displayed after taking
the numbered steps above.
Water heater is overheating.Contact a dealer or qualified service
The heat exchanger is too hot.Check for blockage in the vent. Contact a
Neutralizer is clogged.Contact a dealer or qualified service
Faulty inlet thermistor.Contact a dealer or qualified service
Faulty outlet thermistor.Contact a dealer or qualified service
Faulty blower motor.Contact a dealer or qualified service
Faulty water flow solenoid.Contact a dealer or qualified service
The neutralizer needs to be replaced soon. The unit can be used for a while, but
The neutralizer must be replaced.The unit cannot be used until the neutral-
Not enough water flow to operate the unit.Increase the water flow from the fixtures.
technician.
Remove any blockage. (Air intake requires
12 in. [30 cm] of clearance.)
Contact a dealer or qualified service
technician.
Contact a dealer or qualified service
technician.
technician.
dealer or qualified service technician.
technician.
technician.
technician.
technician.
technician.
contact a dealer or qualified service
technician.
izer is replaced. Contact a dealer or qualified service technician.
IF YOU NEED SERVICE
Care Instructions
Service Information
26
Call for Assistance
1. All questions, adjustments, repairs, and/or
routine maintenance should be directed to
your installer, plumbing contractor, or licensed
service agent. If your contacts have moved or
are not available, please refer to the telephone
directory, commercial listings, or local utility
company for qualified service assistance.
2. If your problem has not been solved to your
satisfaction, contact the Rheem National
Service Department at the following address:
Rheem
National Service Department
1241 Carwood Court
Montgomery, Alabama 36117
Phone: 1-800-432-8373
When contacting the manufacturer, the
following information will be requested:
A. Model and serial number. (See page 8 or the
ratings plate on the front of the water heater.)
B. Address where the water heater is located.
C. Name and address of installation contractors
(page 8) and all qualified service companies
that have worked on the water heater.
D. Original installation date. (See page 8.)
E. Dates any service or preventive maintenance
was performed.
F. Details of the persisting problem.
G. List of businesses that have tried to fix this
problem, along with dates of service.
INSTALLATION
Installation
INSTRUCTIONS
FOR THE CONTRACTOR
INSTALLATION INSTRUCTIONS
Exhaust Vent Pipe
Air Intake Pipe
0" min.
(0 mm)
0" min.
(0 mm)
0" min.
(0 mm)
12"
(300 mm)
Standards Compliance
General
This water heater must be installed in
accordance with these instructions, local
codes, and utility company requirements.
In the United States where local codes are not
available, use the latest edition of the American
National Standard/National Fuel Gas Code. A
copy of the Fuel Gas Code can be purchased
from either the American Gas Association, 400
Choosing a Location
WARNING: Fire Hazard –
Combustible construction refers to adjacent walls
and ceilings and should not be confused with
combustible or flammable products and materials.
Combustible materials, such as clothing, cleaning
materials, or flammable liquids, must not be
placed against or next to the water heater. Fire or
explosion could occur causing death, personal
injury, and/or product damage.
A gas-fired water heater should never be
installed in a space or room where liquids with
flammable vapors are used or stored. Such liquids
include gasoline, LP gas (butane or propane),
paint, adhesives and their thinners, solvents, or
removers. Flammable vapors carry long distances
from where they are used or stored. The open
flame of the water heater’s main burner can ignite
these vapors causing an explosion or fire.
NOTICE: Elevating a gas-fired water
heater will reduce but NOT eliminate the possibility
of lighting the vapor of flammable liquids which
may be improperly stored or accidentally spilled.
North Capitol Street Northwest, Washington,
DC 20001, as ANSI standard Z223.1, or National
Fire Protection Association, 1 Batterymarch
Park, MA 02269 as NFPA 54.
In Canada, use the latest edition of the CSA
B149.1 Natural Gas and Propane Installation
Code and the Canadian Electrical Code,
CSA C22.1, Part 1.
NOTICE: This water heater should not
be located in an area where leakage of the heat
exchanger or connections will result in damage
to the area adjacent to it or to lower floors of the
structures. When such areas cannot be avoided,
install a suitable catch pan with an adequate drain
under the water heater. This drain pan must not
restrict the combustion airflow.
The following requirements will ensure a safe
installation:
• The water heater must be located in an area
where it won’t sustain damaged from moving
vehicles, flooding, etc. If the water heater is
installed in a garage, the direct ignition system
and main burner should be no less than 18 in.
(45 cm) above the garage floor.
• The water heater should be installed as close as
possible to the vent exhaust and air intake. This
minimizes the vent length and the number of
elbows and joints required for venting.
• The water heater should be installed with the
proper venting and exhaust materials.
28
INSTALLATION INSTRUCTIONS
12" min.
(300 mm)
12" min.
(300 mm)
1/2" min.
(13 mm)
12" min.
(300 mm)
0"
(0 mm)
0" min.
(0 mm)
Sealed
Choosing a Location (cont.)
• Every penetration of a floor or ceiling should be
sealed.
• Failure to install and properly vent the water
heater to the outdoors as outlined on pages 33
through 46 can result in unsafe operation.
General
• Minimum water heater clearances from
combustible and noncombustible construction
are as follows:
– 1/2 in. (1.3 cm) for sides
– 0 in. (0 cm) for rear with support bracket(s)
– 12 in. (30 cm) from the bottom, top, and front
• Long hot water lines should be insulated to
conserve water and energy.
• The water heater and water lines should
be protected from exposure to freezing
temperatures.
• Do not install the water heater
outdoors or in bathrooms,
bedrooms, or any occupied rooms
normally kept closed.
• Do not install the water heater
where it is subject to vibrations.
• Do not install the water heater in a
recreational vehicle, mobile home,
boat, or other watercraft.
• Do not install the water heater
near vents for heating and cooling.
If necessary, maintain a minimum
clearance of 4 ft. (1.2 m).
29
INSTALLATION INSTRUCTIONS
Product Inspection
General
• Visually inspect the water heater for any possible
damage.
•
Check the rating plate on the water heater to
make sure the water heater was designed to be
used with the supplied type of gas (natural or LP).
• Verify that all included supplied parts are present
as shown.
Water Heater Installation
Corrosive Atmosphere
NOTICE: The water heater should not be
installed near an air supply containing halogenated
hydrocarbons.
Avoid installing a water heater in any of the
following locations: beauty shops, dry-cleaning
establishments, photo processing labs, and
storage areas for liquid and powdered bleaches or
swimming pool chemicals. These locations often
contain such halogenated hydrocarbons.
30
The air supply containing halogenated
hydrocarbons is safe to breathe, but when
passed through a gas flame, corrosive elements
are released that will shorten the life of any
gas-burning appliance.
Propellants from common spray cans or gas leaks
from A/C and refrigeration equipment are highly
corrosive after passing through a flame.
The water heater warranty is void when the failure
is due to operation in corrosive conditions.
INSTALLATION INSTRUCTIONS
To Hot Water
Faucet(s)
Drain Valve
Wall
Plate
Water
Filter
Cold Water Supply
Shut-O Valve
Power
Supply
Cord
Union
Union
Union
Manual Gas
Supply Line
Shut-O Valve
Downward Slope
Downward Slope
Manual Gas
Shut-O Valve
Cap
Sediment Trap
Outside
Wall
91˚
Elbow
Service
Valve
Service
Valve
Relief
Valve
Relief
Valve
*Note: A exible drain tube can be used
To
Suitable
Drain
To
Suitable
Drain
Condensate
Drain*
Air Intake Pipe
Exhaust Vent Pipe
Water Heater Installation (cont.)
NOTICE: The National Fuel Gas Code (NFGC) and CSA B149.1 mandate a manual gas
shut-off valve. See NFGC/B149.1 for complete instructions. Local codes or plumbing authority
requirements may vary from the instructions or diagrams provided and take precedence over
these instructions.
Typical Installation of Direct-Vent Water Heater (Venting Required)
General
31
INSTALLATION INSTRUCTIONS
Water Heater Installation (cont.)
General
Typical Installation of
Outdoor Water Heater
(No Venting Required)
This water heater is for OUTDOOR
installation only.
Hard-Wire
WARNING: DO NOT install this water
heater indoors or in an enclosure. It is designed for
outdoor installation only. Any other type of installation
can result in death, personal injury, and/or damage to
the product or property.
Flue
Terminal
Water
Filter
To Hot Water
Faucet(s)
Condensate
Drain*
Drain Valve
Service
Service
Valve
Valve
Relief
Union
Union
To Suitable
Drain
*Note: A flexible drain tube can be used
Relief
Valve
Valve
Cold Water Supply
To Suitable
Drain
Shut-Off Valve
Manual Gas
Shut-Off Valve
Union
Sediment Trap
Cap
Manual Gas
Supply Line
Shut-Off Valve
32
INSTALLATION INSTRUCTIONS
Mounting the Water Heater
CAUTION: Reinforcement of the
wall is required in case the wall is not strong
enough to hold the water heater. Failure to do
so could result in personal injury and/or product
damage.
The mounting location for the water heater should
allow for easy access and operation.
Always mount the water heater at the wall studs,
or into a suitable piece of wood that spans the
distance between the wall studs. This piece of
wood can be installed inside or outside of the wall.
Use wood screws to secure brackets to wall. If
mounting to dry wall or concrete wall, use drywall
anchors or lag bolts.
General
3
Using two mounting screws and washers,
secure the lower mounting bracket to the wall.
Then, secure the upper mounting bracket to the
wall with two mounting screws and washers.
1
Make sure the proper electrical outlet or supply
(120 VAC/60 Hz) is available and located near
the unit. Direct-vent models come with a 6-ft.
(1.8-m) power cord, while the outdoor models
require hard-wiring or the addition of a plug.
2
Position the upper mounting bracket and
partially install the center mounting screw. The
clearance between the screw head and the
wall should be about 1/8 in. (0.3 cm). Hang the
upper bracket on the screw.
NOTICE: The image above may differ
in appearance from your water heater.
33
INSTALLATION INSTRUCTIONS
Venting for Direct-Vent Water Heater
DANGER: Failure to properly vent
the water heater to the outdoors as outlined in
this Venting section will result in death or serious
personal injury. To avoid the risk of fire, explosion,
or asphyxiation from carbon monoxide, NEVER
operate the water heater unless it is properly
vented and has adequate air supply for proper
operation as outlined in this Venting section.
Venting
WARNING:
Refer to page 29 for required clearances to
combustible materials. Improper clearances can
cause explosion or fire resulting in death, personal
injury, and/or product damage.
CAUTIONS:
•
Check to make sure flue gases do not recirculate
into the air intake terminal when using direct
venting. If the water heater is having service issues,
flue recirculation may be a contributing factor.
• Even when the minimum vent terminal separation
distances are followed, recirculation may still
occur depending upon the location outside
the building, the distance from other buildings,
proximity to corners, weather conditions, wind
patterns, and snow depth.
• Periodically check to make sure that flue
recirculation is not occurring. Signs of flue gas
recirculation include frosted or frozen intake
terminals and condensate in the intake terminal
and venting system.
• Correction to flue recirculation may involve
angling the intake away from the exhaust
terminal and increasing the distance between
them. Check to be sure the intake and exhaust
terminals are not obstructed, especially during
periods of below-freezing weather.
Venting Requirements
The installation of venting must comply with
national codes, local codes, and the vent
manufacturer’s instructions.
The vent exhaust and air intake must be vented
outside as described in these instructions. DO NOT
vent this water heater through a chimney. It must be
vented separately from all other appliances.
NOTICE: The unit can be vented using
only the following recommended pipe material.
Use only 2- or 3-inch diameter pipe. Refer to local
codes for restrictions on the use of PVC, CPVC, or
ABS pipe and fittings. All exhaust venting materials
for product installed in Canada must meet ULC-S636.
Acceptable materials or equivalent:
PVC (Schedule 40, ASTM D-1785)
CPVC (Schedule 40, ASTM F-441)
34
ABS (Schedule 40, ASTM D-2661) (Not permitted
in Canada)
The fittings, other than the VENT TERMINAL,
should be equivalent to the following:
PVC (Schedule 40 DWV, ASTM D-2665)
DO NOT USE Schedule 20, Cell Core, Drain Pipe,
Galvanized, Aluminum, or B-Vent.
Recommended Vent Lengths
Before starting the vent installation, careful
planning should be given to the routing and
termination of the vent pipes. The length of the
vent pipes (inlet and outlet) should be kept to a
minimum. Also, see pages 37–38 and 44 for vent
terminal placement. Refer to the maximum and
minimum vent length charts for the pipe sizes that
can be used and the total equivalent length of pipe
that can be used. Do not exceed equivalent length
of pipe in maximum vent length chart.
Maximum Vent Length (intake/outlet):
Number
of 90°
Elbows
0 or 15.0 ft. (1.5 m)38.0 ft. (11.6 m)
23.5 ft. (1.0 m)36.5 ft. (11.1 m)
32.0 ft. (0.6 m)35.0 ft. (10.6 m)
4Not available33.5 ft. (10.2 m)
5Not available32.0 ft. (9.8 m)
6Not available30.5 ft. (9.3 m)
The system will not operate if there is excessive
restriction (pressure drop) in the venting system.
Use the chart above to calculate the maximum
pipe run length with the required number of
elbows (e.g., a maximum 38 ft. [12 m] of 3" vent
pipe may be used provided there is only one 90°
elbow in the system).
A 90° elbow is equivalent to 1 ft. 6 in. (0.5 m) of
straight pipe.
The vent termination does not count as part of the
straight pipe equivalent when determining the total
vent length.
Minimum Vent Length:
Number
of 90°
Elbows
11.0 ft. (0.3 m)1.0 ft. (0.3 m)
Maximum
Length of 2"
Straight Pipe
Minimum
Length of 2"
Straight Pipe
Maximum
Length of 3"
Straight Pipe
Minimum
Length of 3"
Straight Pipe
INSTALLATION INSTRUCTIONS
NOTICE: To use 2-inch vent pipe, a
reducing adapter or bushing will be required.
Depending on the size of pipe that is chosen for
venting the water heater, it might be necessary
to use a fitting for stepping down in pipe size, to
connect to the water heater.
All intake and exhaust venting components
must have the same diameter size. Do not use a
different size on the intake and exhaust venting.
The unit may be vented horizontally through a
wall or vertically through the roof. Pipe runs must
be adequately supported along both vertical and
horizontal runs. Maximum unsupported span is
recommended to be no more than 4 feet (1.2 m).
It is imperative that the first hanger be located on
the horizontal runs immediately adjacent to the
first 90-degree elbow from the vertical rise. Only
use support isolation hanging bands. DO NOT use
wire to support pipe runs.
NOTICES:
• It is recommended that the air intake and
exhaust pipes have a 1/4" per foot downward
slope toward the end of the pipes.
• Maintain the proper clearance between the
vent pipe and combustible or noncombustible
materials as described on page 29.
• Maintain a 0-in. (0-cm) minimum clearance
required between the air intake pipes and
combustible material.
• Use proper support for the vent and air intake
pipes.
• Support method used should isolate the
vent pipe from floor joists or other structural
members. This helps prevent transmission of
noise and vibration.
• Do not support, pin, or otherwise secure the
venting system in a way that restricts the normal
thermal expansion and contraction of the chosen
venting material.
See page 36 for additional requirements for the
Commonwealth of Massachusetts.
Venting
Stress levels in the pipe and fittings can be
significantly increased by improper installation.
If rigid pipe clamps are used to hold the pipe in
place, or if the pipe cannot move freely through a
wall penetration, the pipe may be directly stresses,
or high thermal stresses may be formed when the
pipe heats up and expands. Install accordingly to
minimize such stresses.
Preexisting Venting Notes:
If the water heater is being installed as a
replacement for an existing water heater, a thorough
inspection of the existing venting and air intake
system must be performed prior to any installation
work. Verify that the correct materials, vent lengths,
and terminal locations as described in this manual
have been met. Carefully inspect the entire venting
and air intake system for any signs of cracks or
fractures, particularly at the joints between elbows
or other fittings and the straight runs of vent pipe.
Check the system for signs of sagging or other
stresses in the joints as a result of misalignment
of any components in the system. If any of these
conditions are found, they must be corrected in
accordance with the venting instructions in this
manual before completing the installation and
putting the water heater into service.
35
INSTALLATION INSTRUCTIONS
Venting for Direct-Vent Water Heater (cont.)
Venting
In the Commonwealth of
Massachusetts
The Commonwealth of Massachusetts requires
compliance with regulation 248 CMR 4.00 and 5.00 for
installation of through-the-wall vented gas appliances as
follows:
5.08: Modifications to NFPA–54, Chapter 10
(1) Revise NFPA–54 section 10.5.4.2 by adding a second
exception as follows:
Existing chimneys shall be permitted to have their use
continued when a gas conversion burner is installed,
and shall be equipped with a manual reset device that
will automatically shut off the gas to the burner in the
event of a sustained back-draft.
(2) Revise 10.8.3 by adding the following additional
requirements:
(a) For all side-wall, horizontally vented, gas-fueled
equipment installed in every dwelling, building,
or structure used in whole or part for residential
purposes, including those owned or operated by the
Commonwealth and where the side-wall exhaust vent
termination is less than seven (7) feet above finished
grade in the area of the venting, including but not limited
to decks and porches, the following requirements shall
be satisfied.
1. INSTALLATION OF CARBON MONOXIDE
DETECTORS. At the time of installation of the side-wall,
horizontally vented, gas-fueled equipment, the installing
plumber or gas fitter shall observe that a hard-wired
carbon monoxide detector with an alarm and battery
backup is installed on the floor level where the gas
equipment is to be installed. In addition, the installing
plumber or gas fitter shall observe that a batteryoperated or hard-wired carbon monoxide detector
with an alarm is installed on each additional level of
the dwelling, building, or structure served by the sidewall, horizontally vented, gas-fueled equipment. It shall
be the responsibility of the property owner to secure
the services of qualified licensed professionals for the
installation of hard-wired carbon monoxide detectors.
a. In the event that the side-wall, horizontally vented,
gas-fueled equipment is installed in a crawl space or
an attic, the hard-wired carbon monoxide detector with
alarm and battery backup may be installed on the next
adjacent floor level.
b. In the event that the requirements of this subdivision
cannot be met at the time of completion of installation,
the owner shall have a period of thirty (30) days to
comply with the above requirements, provided, however,
that during said thirty (30) day period, a batteryoperated carbon monoxide detector with an alarm shall
be installed.
2. APPROVED CARBON MONOXIDE DETECTORS.
Each carbon monoxide detector as required in
accordance with the above provisions shall comply with
NFPA 720 and be ANSI/UL 2034-listed and IAS-certified.
3. SIGNAGE. A metal or plastic identification plate
shall be permanently mounted to the exterior of the
building at a minimum height of eight (8) feet above
grade directly in line with the exhaust vent terminal for
the horizontally vented, gas-fueled heating appliance
or equipment. The sign shall read, in print size no less
than one-half (1/2) inch in size, “GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
4. INSPECTION. The state or local gas inspector of the
side-wall, horizontally vented, gas-fueled equipment
shall not approve the installation unless, upon
inspection, the inspector observes carbon monoxide
detectors and signage installed in accordance with the
provisions of 248 CMR 5.08 (2)(a)(1 through 4).
(b) EXEMPTIONS: The following equipment is exempt
from 248 CMR 5.08 (2)(a)(1 through 4):
1. The equipment listed in Chapter 10 entitled
“Equipment Not Required To Be Vented” in the most
current edition of NFPA 54 as adopted by the Board,
and
gas-fueled equipment installed in a room or structure
separate from the dwelling, building, or structure used in
whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS – GAS
EQUIPMENT VENTING SYSTEM PROVIDED. When
the manufacturer of product-approved side-wall,
horizontally vented, gas-fueled equipment provides a
venting system design or venting system components
with the equipment, the instructions provided by the
manufacturer for installation of the equipment and the
venting system shall include:
1. Detailed instructions for the installation of the venting
system design or the venting system components; and
2. A complete parts list for the venting system design or
venting system.
(d) MANUFACTURER REQUIREMENTS – GAS
EQUIPMENT VENTING SYSTEM NOT PROVIDED.
When the manufacturer of product-approved sidewall, horizontally vented, gas-fueled equipment does
not provide the parts for venting the flue gases, but
identifies “special venting systems,” the following
requirements shall be satisfied by the manufacturer:
1. The referenced “special venting systems” instructions
shall be included with the appliance or equipment
installation instructions, and
2. The “special venting systems” shall be product-
approved by the Board, and the instructions for that
system shall include a parts list and detailed installation
instructions.
(e) A copy of all installation instructions for all
product-approved side-wall, horizontally vented,
gas-fueled equipment, all venting instructions, all
parts lists for venting instructions, and/or all venting
design instructions shall remain with the appliance or
equipment at the completion of the installation.