Product Description
Jet Swim is an apparatus used for training, exercise and recreation. It features an adjustable jet stream for personal
customisation of the water ow and air admixture.
Jet Swim 1200 consists of four parts:
Base kit 1301200 Assembly kit 1301210 Liner, 1301220 Concrete/liner or 1301230 Concrete Pump kit 1301280 (50Hz), 1301280HZ (60Hz) Control box 1301290 400V, 130129NO 230V Norway only
The pump section is installed on a stable surface in a dry area. Make sure that the area is well ventilated and is equipped with a drain in order to prevent ooding.
All installation of stainless steel parts shall be done using tools solely intended for such material in order to maintain its corrosion­resistance.
Technical Data
Motor 2.2 kW
Volage 230/400V 50Hz 3N~ 265/460V 60Hz 3N~
Current 8.0 / 4.6 A 6.8 / 3.9 A
Pump capacity 46 m3/h 43 m3/h
Enclosed protection class IP55
Dimensions
Recommended water quality values for this product:
Outside these values the product warranty does
not apply.
Total chlorine content: max 3.5 mg/liter*
Chloride (salt) content: max 250 mg/liter
pH-value: 7.2–7.6
Alkalinity 60–120 mg/liter (ppm)
Calcium hardness: 100–300 mg/liter (ppm)
Iron:
max 0.1 mg/liter*
Copper:
max 0.2 mg/liter*
Manganese:
max 0.05 mg/liter*
Phosphorus: max 0.01 mg/liter*
Nitrate: max 50 mg/liter*
*According to EN16713-3 2016
Dimensions put in brackets refer to item no.1301210 for liner pools with walls made of wood, sheet or
plastic.
Drain
Page 2
7
Jet Swim 1200
MA30-01 GB
ENGLISH
U1
V1
W1
246
2
4
6
14 13
1
3
5
1
K1
1,5~D
2,5~D
B1
F2
M1
P
NO COM
F1
3
5
135
A1A2
2
4
1
3
9695
L1
L2
L3
M
W2 U2 V2
U1 V1 W1
U1
V1
W1
2
4
6
2
4
6
14 13
1
3
5
1
K1
2,5~D
B1
M1
P
NO COM
F1
3
5
135
A1
A1A29695
L1
L2
L3
N
M
W2 U2 V2
U1 V1 W1
CENELEC* members:
Note! The appliance can be used by children from the age of 8 and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
* CENELEC members are: Austria, Belgium, Bulgaria, Croatia, the Czech Republic, Denmark, Estonia, Finland, Germany, Greece, Hungary, Iceland, Ireland, Italy Latvia, Lithuania, Lucembourg, Malta, the Netherlands, Norway, Poland, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Other countries than CENELEC members (according to IEC):
Note! This appliance is not intendend for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Safety
The jet stream is powerful, which is why one should not be closer than 0.5 m from the stream outlet for a protracted period. People with long hair should pay careful attention so that their hair does not get stuck in the inlets (the perforated openings in the stainless steel front).
Small children should not be in the pool without supervision, especially not when the Jet Swim device is in operation. Always inform all the other bathers in the pool before starting the Jet Swim.
Always check that the current to the pump is disconnected before commencing any work, service or maintenance of the pump.
Pressure switch
Connector
Motor circuit breaker
PE
Micro
switch
Connector
Motor circuit breaker
PE Pressure switch
Electrical Installation
All electrical connections shall be made by an authorised electrician.
The device shall be tted with a residual current device with max breaking capacity 30mA. The pump motor is connected via the control box for Jet Swim 1200, see the circuit diagram.
Check the rating plate on the pump motor for the correct connection on the closing link.
Make sure that the pump motor has been connected in the correct direction of rotation (see the rotation direction arrows on the pump motor). The wrong direction can damage the pump.
N.B.! The pump must never be started without being lled with water.
Make sure that the motor protection in the control box is set according to the rated current of the pump motor; see the rating plate.
Circuit Diagram
3~400V 3~230V
Page 3
8
Jet Swim 1200
MA30-01 GB
ENGLISH
Jet Swim 1200 ( Front panel )
Figure 1.
Front Jet Swim 1200
A
On/O󰀨
B
Low
C
High
D
High + Air
Installation - Liner pool
1. Remove the stainless steel front and cut out the pool wall according to the hole pattern. The centre of the Jet Swim housing
shall rest 230 mm under the surface of the water.
2. Install the Jet Swim housing in the wall of the pool. Then attach the self-adhesive gasket on the bronze part.
3. Put the pool liner in place. Fill the pool with water. When the water reaches about 5 cm below the Jet Swim housing,
the clamping ring and rubber washer are screwed in place against it. Cut away the pool liner from the inside of the clamping ring and install the stainless steel front plate.
4. Connect the hose for the air injecion and tighten the hose clamp. Then attach the end of the hose 100 mm above the surface of the water behind the pool wall.
5. Attach the starting hose to the pump’s contactor cabinet (control box).
N.B.! The starting hose must be xed in a loop 150–200 mm above the surface of the water.
6. Connect the pipes and valves to the pump according to the image (page 6). The threads are sealed with thread seal tape.
7. The electrical connection must be made by an authorised electrician and be equipped with a residual current device.
8. Make sure that the pump’s direction of rotations is consistent with that of the system. Open the valves. Completely ll the pump with water before starting it with the push-button (A g.1) on the stainless steel front.
9. The front can be turned one step to the right or to the left to control the water ow and to have air mixed into the water jets, see g. 1.
Installation - Concrete pool
1. Remove the stainless steel front and install the Jet Swim housing in the form. The nished pool wall shall be in line with the ange on the bronze housing. The centre of the Jet Swim housing shall be located 230 mm under the surface of the water.
2. Attach the start hose to the Jet Swim housing and install the non leak anges for the suction and pressure connections and the non leak anges for the air injection and start hose (protective hose) before casting. The threads are to be sealed
with thread tape.
3. Install the stainless steel front plate after the casting (and any tiling).
4. Connect the hose for the air admixture and tighten the hose clamp. Fasten the end of the hose 100 mm above the surface
of the water behind the pool wall.
5. Connect the starting hose to the pump’s contactor cabinet (control box).
N.B.! The starting hose must be set in a loop 150–200 mm above the surface of the water.
6. Connect the pipes and valves to the pump according to the image (page 6). The threads are sealed with thread seal tape.
7. The electrical connection must be made by an authorised electrician and be equipped with a residual current device.
8. Make sure that the pump’s direction of rotation is consistent with that of the system. Open the valves. Completely ll the pump with water before starting it with the push-button (A g.1) on the stainless steel front.
9. The front can be turned one step to the right or to the left to control the water ow and to have air mixed into the water jets, see g. 1.
Installation - Concrete pool with liner
Install according to point 1 - 2 for concrete pools and point 3 - 9 for liner pools.
Start
The pump must be lled with water prior to starting. Never run the pump dry, as that can damage the parts inside. Make sure that all the valves to and from the
pump are open prior to starting.
The Jet Swim pump is started and stopped by air impulse via the pushbutton (A) on the stainless steel front (see g.1). To control the water ow and to have air mixed into the water jets: turn the front one step to the right or to the left (see g. 1) :
B = low jet pressure C = high jet pressure D = high jet pressure with air added.
Please note
Upon risk of freezing: close the valves, remove and drain the pump of all water. Lower the water level to approximately 10 cm under the Jet Swim housing in
order to avoid freezing damage. The pump should be store indoors during the winter.
When restarting: Check the condition of the starting button and the hoses.
Page 4
24
Jet Swim 1200
MA30-01 GB
ENGLISH
1
10
14
15
16
20
18
19
22
23
12
13
17
6
5
4
3
2
8
7
9
21
11
Jet Swim 1200
24
1
3
2
10
14
15
16
4
20
18
19
12
13
5
6
17
21
8
7
Jet Swim moel 1200 onrete wit liner
Dwg.no: M10190-2 130528 OA
11
9
24
3
2
1
4
14
15
16
12
13
19
18
20
5
17
6
8
7
Jet Swim moel 1200 onrete
21
1201200 Grundsats / Base kit / Базовый комплект / Basis-Kit / Juego básico / Kit di base / Zestaw bazowy + Monteringssats / Mounting set / монтажный комплект / Montageset / Juego de montaje /
Kit di montaggio / Zestaw montażowy
1201220
Mursten med liner / Building block with liner / Бетон с пленкой / Baustein mit Folie / Mampostería con revestimiento / Muratura con liner / Cegiełki z wykładziną
1201230
Betong / Concrete / Бетон / Betongbecken / Hormigón / Cemento / Beton
1201210
Liner / Liner / Пленка / Folie / Revestimiento / Liner / Wykładzina
Page 5
25
Jet Swim 1200
MA30-01 GB
ENGLISH
Pos Pos
Pos Nº Pos Poz.
Antal Quantity
Кол-во
Menge Cantidad Q.tà
Ilość
Benämning Description
Описание
Beschreibung Descripción Denominazione Opis
1301200
1301210
1301220
1301230
1 1 Front plate
2 3 Screw MRX A4 M6x12
3 1 Start button complete
4 1 Turning insert
5 1 Jet Swim 1200 housing
6 A 2 Hexagonal nipple 2”, brass
6 B 2 Non leak ange, 2” connection, L = 250 mm
7 1 Gate valve 2”, brass
8 1 Gate valve 2”, devided, brass
9 1 Clamping ring
10 1 Rubber gasket Ø258 mm, t = 2 mm
11 8 Screw MRX A4 M5x12
12 2 Screw MC6S A4 M8x16
13 2 Bushing nylon
14 1 O-ring 4.10x1.60 mm
15 1 Connection pin
16 2 Spring washer
17 A 2
1pc. Short hose connection air injection 1pc. Short protective pipe start hose
17 B 2
1pc. Long hose connection air injection 1pc. Long protective pipe start hose
18 1 Hose for air injection 8x12 mm, L = 0.8 m
19 1 Hose clamp 8–14 mm
20 1 Hose for start 2x4 mm, L = 1.5 m
21 1 O-ring 8.60x2.40 mm
22 4 Screw MFX A4 M6x30
23 4 Nut M6M A4 M6
24 1 Rubber gasket Ø258 mm, t = 1.5 mm self-adhesive
Page 6
26
Jet Swim 1200
MA30-01 GB
ENGLISH
M10429511701
Axelskydd 1,5-4kW
1
19
M1023094150
Nippel Ø63x79x2"utv
2
18
Tryckslang
1274270
Slang 2½" tryck/sug L=125mm
2
17
Slangklammer
122427
Slangklämma 68-73mm (2½")
4
16
51291
Packning Cu 8,3x12x0,85
115
19901411
Skruv M6S M8x12
114
R10064
51234
Pumphus JET 2,2kW
1
13
R1116719932032
Kupolmutter M12
1
12
R10372511870
Pumphjul Jet 96 2,2kW
111
(M11440)
511522
Axeltätning Type 2106
1
10
R1116651103O-ring 139,5x3 NBR70
1
9
R11160
51165
Platta för tätning P89/2000
1
8
1
6
5
7
3
2
4
19
8
9
11
12
10
13
15
14
17
16
18
REVISION HISTORY
2
Pos 10 Axeltätning var 511521
2013-03-06 OA
2
21
20
Pos Pos
Pos Nº Pos Poz.
Antal Quantity
Кол-во
Menge Cantidad Q.tà
Ilość
Benämning Description
Описание
Beschreibung Descripción Denominazione Opis
1301280-011301290
130129NO
1-12 Drivsida
1 1 Motor 2.2kW 400/230/50-460/265/60 3-phase A200/24 IE2
2 1 Shaft
3 3 Set screw SK6SS A4 M8x10
4 1 Intermedia plate
5 4 Screw M6S A4 M10x30
6 4 Nut M6M A4 M10
7 4 Screw M6S A4 M10x25
8 1 Plate for seal
9 1 O-ring 139.50x3.00
10 1 Shaft seal
11 1 Impeller Jet 2.2kW
12 1 Domed nut M12
13 1 Pump housing
14 1 Drain plug (screw M6S A4 M6x10)
15 1 Gasket drain plug
16 4 Hose clamp 2½”
17 2 Pressure hose 2½” L = 125 mm
18 2 Hose connection 2”x63 mm
19 1 Axelskydd
20 1 Control box 400V
20 1 Control box 230V
21 1 Pressure switch
1201280
Pumpsats Pump kit Hacoc Pumpensatz Juego de bombeo Kit pompa Pompa
1201290
Styrskåp Control box Блок управления Schaltschrank Armario de control Armadio automatico Skrzynka kontrolna