The information contained in this document is correct at the time of publication. PAG Ltd. reserves the right to
change specifications or product details without notification. Changes to product details will be incorporated
in the next version of the document. PAG updates documents on a regular basis.
Trademarks
All PAG registered trademarks are the property of PAG Ltd. All third party trademarks are acknowledged as such.
1.1This booklet contains important safety and operating instructions. Please read it
fully and note all warnings before using the charger. Please follow all
instructions and retain this manual for future reference. A PDF version of this
manual is available to download from the PAG website at www.paguk.com
1.2PAGlink PL16 & PL16+ chargers are not intended for any use other than the
charging of batteries as detailed in Section 2 Specification.
IMPORTANT: Use only on AC supplies 100-265V, 50/60Hz. Supply connection to
1.3
the unit should be made using only the standard lead supplied with this
equipment.
1.4Protect the power cord from being walked on or pinched, particularly at plugs.
Unplug this apparatus during lightning storms or when unused for long periods
of time.
1.5Ensure that the ventilation slots are not obstructed when in use, e.g. do not
site the charger on a carpet, and ensure that nothing covers the charger when
it is in use.
WARNING: Indoor use only. To reduce the risk of fire or electric shock, do not
1.6
expose this apparatus to rain or moisture.
1.7Although the charger is short circuit protected, extreme care should always
be taken not to short circuit the battery itself. Rechargeable batteries can
deliver power at a very high rate, and short circuiting even a partially charged
battery could result in a fire or personal injury.
1.8WARNING: This appliance must be earthed.
1.9Users who are not qualified electronics technicians must not attempt to
disassemble the charger. There are no user-serviceable parts inside, and
incorrect reassembly may result in a safety hazard.
1.10Do not use the apparatus if it has been damaged in any way, for example:
the supply cord or plug is damaged; liquid has entered the apparatus; it has
been exposed to rain or moisture; it does not operate normally or it has been
dropped. In these circumstances, seek advice from your nearest authorised PAG
Service Centre, or direct from PAG UK, by telephoning +44 (0)20 8543 3131, or
emailing support@paguk.com
Up to 8 PAGlink batteries can be charged on each position. Batteries can be
in any state of charge. The most discharged batteries will be given priority.
Fully charged batteries stop accepting charge automatically and independently.
Batteries may be left on the charger when fully-charged and will be
maintained in a ready-for-use condition.
2.5Recovery Charge Program:
A battery that will not accept charge, and is indicated as ABST on the charger
display, can be given a Recovery Charge, initiated by two presses of the front
panel button on PL16 Chargers (Models 9707 & 9707A). Normal charging will
follow after a few seconds. Recovery Charge will be applied automatically in the
case of PL16+ chargers (Models 9711 & 9711A). Additionally, all chargers will
recover automatically a Li-Ion battery where the output has been shut down.
2.6Self Test Program:
The internal microcomputer constantly monitors the battery under charge, as
well as the operation of the charger’s own functions, which will be shut down
to a safe condition should any of the tests fail.
2.7Mains Input:
100V to 265V AC. Frequency 50-60 Hz. Maximum consumption 220W.
2. 8Output Protection:
The charger is protected against short circuit and excess battery voltage.
2.9AC Mains Failure Protection:
Should mains failure occur during a charging program, or whilst the charger is
connected, it will shut down to a safe condition.
2.10 User Interface:
The charge status of each PAGlink battery is indicated by its own display.
The different stages of the charging process are indicated for each channel on
the charger’s LCD screen. The charger is fully automatic in operation.
2.11 Safety:
Designed to comply with electrical safety standard BS EN 60065 and UL1564.
NOTE: UK AC power leads are fitted with a 1" fuse to BS1362 rated 5A.
2.12 European Union Directives:
Complies with the following EU Directives:
EMC Directive 2004/108/EC.
Low Voltage Directive 2014/35/EU.
2.13 Operating Temperature Range:
0ºC to +40ºC (+32ºF to +104ºF).
6
Page 7
2.14 Overall Dimensions & Weight:
9707 PL16 V-Mount:
H 75mm (3.0”)W 210mm (8.3”) D 190mm (7.5”)1.4kg (3lbs).
9707A PL16 Gold Mount:
H 75mm (3.0”)W 220mm (8.6”) D 190mm (7.5”)1.4kg (3lbs).
9711 PL16+ V-Mount:
H 75mm (3.0”)W 217mm (8.5”) D 315mm (12.4”)1.6kg (3.5lbs).
9711A PL16+ Gold Mount:
H 75mm (3.0”)W 217mm (8.5”) D 315mm (12.4”)1.6kg (3.5lbs).
2.15 Typical Battery Charging Times:
The charge times given are for 96Wh PAGlink batteries, from fully-discharged to
fully-charged. Charge times will be less if batteries are only partially discharged,
and will vary depending on the condition of the batteries. Charge times for
150Wh batteries will be approximately 50% longer.
Total:Configuration:Time:
12 hrs 30 mins
2(1 / 1)3 hrs
4(2 / 2) or (1 / 1 / 1 / 1)6 hrs
6(3 / 3) or (2 / 2 / 1 / 1)9 hrs 30 mins
8(4 / 4) or (2 / 2 / 2 / 2)11 hrs 45 mins
16(8 / 8) or (4 / 4 / 4 / 4)24 hrs
32(8 / 8 / 8 / 8)48 hrs
2.16 Camera Power Supply (Models 9707 & 9707A only):
Suitable for powering cameras that can accept a 16.8V input.
2.17 Operation:
The camera power supply function is operated by pressing and holding the
Camera PSU button on the charger’s front panel for 1 second. Charging is
suspended whilst the power supply is in use.
2.18 Output:
16.8V DC. Maximum current 5.5A (90W).
2.19 Output Connector:
XLR4F connector (Pin 1 Neg, Pin 4 Pos).
7
Page 8
SECTION 3
OPERATING INSTRUCTIONS
3.1PAGlink PL16 Chargers are fitted with an AC input socket conforming to CEE22
(IEC socket). AC supply connection to the charger should be made using only
the standard lead supplied with this equipment.
3.2PAGlink PL16 Chargers have been designed for use on AC supplies worldwide,
and automatically accept supplies in the range 100V to 265V. AC supply
frequency must be in the range 50-60Hz.
IMPORTANT: Note section 3.17 Supply Failure. PAGlink PL16 Chargers may be
3.3
disconnected from the supply at any time in complete safety and without
damage to the charger or any batteries connected.
3.4Connect the charger to a suitable supply using the standard lead. The red LCD
screen will illuminate.
3.5On power-up, the charger will automatically run a self test program.
3.6With no batteries connected, the display will indicate ‘ABST’ on each channel:
PL16 DisplayPL16+ Display
3.7When batteries are connected, charging will automatically commence and the
charger display will indicate ‘CHRG’ on the appropriate channels:
PL16 DisplayPL16+ Display
3.8Up to 8 PAGlink batteries per channel may be charged. Batteries can be
in any state of charge. The most-discharged batteries will be given a higher
charge priority. The charge status of each PAGlink battery is indicated by its
own display. Fully-charged batteries stop accepting charge automatically and
independently of other batteries.
8
Page 9
3.9The charger display will indicate ‘DONE’ when all the batteries connected to
that channel have received as much charge as they can safely accept:
PL16 DisplayPL16+ Display
3.10As Li-Ion batteries near the end of charge, the charge current is reduced.
This is perfectly normal for the ‘constant voltage’ phase of the charge cycle.
3.11Batteries may be removed, and others connected at any time, without affecting
the operation of the charger.
3.12The charger will continue to monitor the status of all charging channels.
It will not attempt to charge batteries which the charger indicates are ‘DONE’
or faulty (indicated as ‘FAIL’). When there are no batteries connected the
charger display will indicate ‘ABST’:
PL16 DisplayPL16+ Display
If a new battery is connected to the free channel, the charging sequence will
be initiated automatically. The order in which batteries are connected is
therefore immaterial; the charger will ensure that all batteries are charged in
as short a time as possible.
3.13If the charger detects a faulty battery while the charging program is running,
the display will show ‘FAIL’. This could be caused by one of several conditions,
such as a very old or damaged battery, a short circuit battery, or an excessively
high or low voltage battery.
3.14The charger will not recognise the connection of a battery which has a
voltage substantially outside of its range or one of unsuitable chemistry type.
3.15If the internal protection circuit of a PAG or Sony Li-Ion battery should turnoff, for any reason, the battery display will not operate, and there will be no
voltage at the battery terminals. The PL16 incorporates a Recovery Charge
program which will automatically turn the protection circuit back on again.
3.16If the charger should detect a fault during operation, it will shut down to
a safe condition. See Section 5.4 ‘Servicing and Repairs’.
9
Page 10
3.17If the AC mains power fails during operation, the charger will shut-down
safely; no damage will occur to either the charger or the batteries. When the
mains power is restored the charger will default to the main charge program.
3.18PL16 Chargers, Models 9707 & 9707A feature a built-in Camera Power Supply
that enables you to power your camera from an AC mains supply, using the
charger. Connection to the camera can be made using an XLR4 male to female
adaptor lead (PAG Model 9450). The power supply is operated by pressing the
button on the front panel of the charger, and holding it in for 1 second.
The blue LED above the button will light to indicate the power supply is in
operation. When the camera power supply is in use, charging is suspended
SECTION 4
SERVICING OR REPAIRS
WARNING: To reduce the risk of electric shock, do not attempt any servicing or
4.1
repairs unless you are qualified to do so. Refer all servicing or repairs to
qualified servicing personnel. The charger contains advanced electronics that do
not require periodic maintenance. Consequently there are no user-serviceable
parts inside.
4.2Qualified electronics engineers who wish to gain access to internal assemblies
should note that parts of the power circuit retain a high voltage even after the
power supply has been disconnected. Wait for a period of five minutes following
disconnection before commencing disassembly, and be aware of charged
capacitors.
4.3When the charger is correctly connected to an AC supply and the display is not
functioning, it may be that a supply fuse has become open circuit. Equipment for
use in the UK is supplied with a standard AC power lead, complete with a
moulded, fused plug. If this fuse has become open circuit it should be replaced
by another of the correct rating (see Specification Section 2.11). USE ONLY A
FUSE OF THE CORRECT RATING. If the replacement of the fuse fails to correct the
above symptoms, do not attempt further fuse replacement, it is likely that a
fault has developed. Contact your nearest authorised PAG Service Centre:
If you are located outside the US and the UK please visit www.paguk.com/
agents to discover your nearest point of contact.
10
Page 11
4.4The chargers feature a fail-safe shutdown mode. In the unlikely event of an
internal malfunction, an error message will be displayed on the screen. This
could be the result of any number of undesirable situations from which the
system is protecting itself, such as the obstruction of ventilation slots, causing
inadequate cooling, or the microcomputer’s detection of an internal fault.
In these cases the charger should be disconnected from the supply, any
obstruction of the air vent system removed, and the unit allowed to cool before
reconnecting to the supply. Should the charger re-enter the fail-safe shutdown
mode, more detailed investigation is required. Make a note of the error message
and seek advice from your nearest authorsied PAG Service Centre.
4.5Unqualified personnel should not attempt further investigation (see paragraph
4.1 above). Any such interference would invalidate the guarantee and could
cause more damage than the original fault.
For technical information contact PAG by telephone on +44 (0)20 8543 3131
or email: support@paguk.com.
SECTION 5
SECTION 6
GUARANTEE
5.1Notwithstanding any provision of any agreement the following guarantee is
exclusive: PAG Limited guarantees each PAGlink PL16 charger it manufactures
to be free of defects in material and workmanship under use and service for
TWO YEARS from the date of purchase. This guarantee extends only to the
original purchaser. This guarantee shall not apply to fuses or any product or
parts which have been subject to misuse, neglect, accident or abnormal
conditions of operation.
5.2In the event of failure of a product covered by this guarantee, PAG Limited will
repair and calibrate equipment returned to an authorised service facility within
the period of the guarantee, provided the guarantor’s examination discloses to
its satisfaction the product was defective. The guarantor may, at its option,
replace the product in lieu of repair. With regard to any equipment returned
within this period, said repairs or replacements will be made without charge.
If the failure has been caused by misuse, neglect, accident or abnormal
conditions of operation, repairs will be billed at a nominal cost. In such a case,
an estimate will be submitted before work is started, if requested.
5.3The foregoing guarantee is in lieu of all other guarantees, express or implied,
including but not limited to any implied guarantee or merchantability, fitness or
adequacy for any particular purpose or use. PAG Limited shall not be liable for
any special, incidental, or consequential damages, whether in contract, tort, or
otherwise.
11
Page 12
PAG Ltd.
565 Kingston Road
London SW20 8SA
E sales@paguk.com
T +44 (0) 20 8543 3131
www.paguk.com
EU DECLARATION OF CONFORMITY
WePAG Ltd.
London, England.
hereby declare that the products listed below are in conformity with the following
European directives and harmonized European standards. This declaration shall
cease to be valid if modifications are made to the products without our approval.
PRODUCT:PAGlink PL16 & PL16+ Chargers
MODELS:9707, 9707A, 9711 & 9711A
APPLICABLE EU DIRECTIVES:EMC DIRECTIVE 2004/108/EC
LOW-VOLTAGE DIRECTIVE 2014/35/EU
CE MARKING DIRECTIVE 89/336/EEC
HARMONISED STANDARDS APPLIED:GENERIC:
BS EN 6001-6-3:2007 +A1:2011
EN 61000-6-1
PRODUCT SPECIFIC:EN 55032 CLASS A
BS EN 61000-4-2:2009
BS EN 60335-1:2012 +A13:2017
IEC 60335-1:2010 +AMD1:2013 +AMD2:2016 CSV
Signed for and on behalf of PAG Ltd.
Alan Lavender
Chief ExecutiveDate: 01.05.17.