PACOM PAC-24RM1616 User Manual

CCTV Power Supply Manual
16 Channel =(2 x 8Channel) with Dual Volt / Amp meter
24VAC 1.5U Rack Mount
Model: PAC-24RM1616(S84745)
8
Overview: This PACOM Rack Mount CCTV Power Supplies provides 24VAC distributed via sixteen (16) PTC protected outputs for powering CCTV Cameras and other video accessories.
Notes: 2 Power On/Off Switches have been provided for each of the 8 Channels at the rear of the Rack case
Caution: Always test for correct output voltage ( 24VAC) before connecting power to cameras or other equipment. Temporarily power up the unit and measure the AC output voltage to avoid damage to devices. Then disconnect power before connecting external devices.
1. Mount unit in the desired rack location. To maintain Air Circulation, allow a minimum gap of 50mm on both sides and above the rack mount unit.
2. Unplug Green terminal connector blocks from their sockets for easy installation.
3. Tech Tip: All Cameras with similar power cable length should be grouped together on the same terminal block.
4. Connect cameras or other equipment power input cables to the screw terminals side by side in pairs.
5. Screw the terminals closed, making sure that there are no loose connections. Once this is done, insert the terminal block back into its correct slot.
6. Select the power on switch A or B for each of the 8 Channels
7. Connect the unit’s power cord to a 240VAC outlet and secure with safety clip. Switch on power to the unit.
8. Front-panel LEDs should illuminate Green if the Channel is not being used and Blue if the channel or channels are being used. Red if the Channel has a short circuit on the output lines.
9. Test the output at the camera end of each power cable to be sure voltage is within range as specified by the Camera manufacturer.
Tri-Colour LED status indicator for each output:
10. Volt meter operational range 5V - 69.9V
11. Amp meter operational range 200mA -8Amp For current load > 8 Amps ,<9 Amps Amp Meter display will Flash the current value For current Load Greater than 9.00 Amps, the Amp Meter display will read OL= Over Load.
12. RyA and RyB are N/C relay contact.
Front Panel
Rear Panel
PAC-24RM1616(S84745) PAC-24RM1616(S84745)
Green
Blue
Red
Open Circuit
Closed Circuit < 120mA load
Short Circuit PTC Fuse tripped
Procedure for resetting PTC fuse:
Remove short in the circuit.
• Switch off PSU switches either A or B (relevant to the short) for a period of 30 seconds,
then switch back on and PTC fuse will reset automatically.
24.3
6.55
24.3
5.75
CAUTION: To reduce the risks of electric shock do not open enclosure. There is no user serviceable parts inside. Refer servicing to qualified service personnel. Replace fuses with the same type and rating T3A/250V Rack Mount Mechanical Dimensions 437*277*64mm