Packard 320725-753 Installation Instructions Manual

PSC Inducer Motor
Housing Assembly Kit
Installation Instructions
Part No. 320725-753
NOTE: Read the entire instruction manual before starting the
installation. This symbol indicates a change since the last issue.
SAFETY CONSIDERATIONS
Untrained personnel can perform basic maintenance functions such as cleaning coils or cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to the unit.
Follow all safety codes. Wear safety glasses and work gloves. Have fire extinguisher available.
Recognize safety information. This is the safety-alert symbol When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAU­TION. These words are used with the safety-alert symbol. DAN­GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.
Before beginning any installation or modification, be sure the main electrical disconnect switch is in the OFF position. Electrical shock can cause personal injury or death.
Label all wires prior to disconnection when servicing con­trols. Wiring errors can cause improper and dangerous operation.
INTRODUCTION
This instruction covers installation of the permanent split capacitor (PSC) inducer motor kit Part No. 320725-753 on models 340MAV, 345MAV, 350MAV, 490AAV, 58MCA, 58MSA, and 58MXA Condensing Gas Furnaces. See Table 1 for kit applica­bility.
Cancels: IIK 340M-40-15 IIK 340M-40-24
11-96
Table 1—Kit Usage
MODEL
NUMBER
340MAV 350MAV 490AAV
340MAV 350MAV 490AAV
345MAV A
58MCA 58MXA
58MCA 58MXA
.
58MSA 101
* For 060120 and 120-20size units on models and series specified, use high output PSC inducer motor housing assembly kit, Part No. 320725-754. For 060140 and 140-20 size units on models and series specified, use high output PSC inducer motor housing assembly kit, Part No. 320725-755.
Use this PSC inducer motor kit to replace a failed inducer motor assembly.
This kit contains the following items:
Inducer assembly 1 Installation Instructions 1
NOTE: Inducer assembly consists of motor and fan, capacitor, wheel, motor mount, inducer cover, inducer housing, vent cap, and vent clamp.
Step 1—Remove Old Motor Assembly
1. Turn off gas and electrical supplies to unit.
2. Remove main furnace door.
3. Remove drain tube from inducer motor mounting cover plate.
4. Remove pressure switch tubes. (See Fig. 1.) a. Remove tube attached to pressure switch from collector
box.
b. Remove tube attached to pressure switch from burner
enclosure and gas valve.
5. Remove screw securing pressure switch and capacitor to inducer housing.
6. Disconnect motor lead connector at quick-connect.
7. Using backup wrench, disconnect gas supply pipe from gas valve.
8. Remove wires from gas valve. Note location for reassembly.
9. Remove burner box cover.
10. Remove screws securing manifold to burner box.
SERIES USED ON
A B C
D
101 111 121
131
All Sizes
All Sizes Except
060120 and 060140*
All Sizes Except
060120*
All Sizes
All Sizes Except
120-20 and 140-20*
All Sizes Except
DESCRIPTION AND USAGE
INSTALLATION
120-20*
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4 Tab 6a 8a
PC 101 Catalog No. 565-826 Printed in U.S.A. Form 58M-39SI Pg 1 11-96 Replaces: 58M-37SI
COMBUSTION-AIR
JUNCTION BOX
CONDENSING
(BEHIND CELL
INLET PANEL)
INDUCER MOTOR
INTAKE
CONNECTION
GAS VALVE
AUXILIARY
VENT OUTLET
HEAT
EXCHANGER
PRESSURE
SWITCH
CONDENSATE
TRAP
MOTOR AND
BLOWER
ASSEMBLY
AIR FILTER AND
RETAINER
BURNER ENCLOSURE
PRIMARY HEAT EXCHANGER (BEHIND CELL INLET PANEL)
CAP AND CLAMP (UNUSED DRAIN CONNECTION)
VENT OUTLET CONTROL
CENTER BLOWER
ACCESS PANEL SAFETY INTERLOCK SWITCH
A96236
NOTE: Actual component location may vary depending on model and series.
Fig. 1—Inducer Motor Assembly in Upflow
Furnace Orientation
PAM
RTV
A93081
Fig. 2—Inducer Housing to Collector Box Gasket
11. Remove manifold, orifices, and gas valve as 1 assembly.
12. Remove 4 bolts attaching inducer housing assembly to heat exchanger cell panel.
Step 2—Install New Motor Assembly
1. Inspect seal on collector box. (See Fig. 2.)
NOTE: If collector box seal is damaged in any way, it must be repaired. To repair, apply sealant releasing agent such as PAM cooking spray or equivalent (must not contain corn or canola oil, aromatic or halogenated hydrocarbons) to inducer housing. Apply a small bead of G.E. RTV 162, G.E. 6702, or Dow-Corning RTV 738 sealant to groove in collector box. G.E. 162 (P771-9003) is available through RCD in 3-oz. tubes.
2. Remove 4 bolts and spacers from old inducer housing assem­bly.
3. Install spacers in new inducer housing.
4. Insert bolts through inducer housing.
NOTE: Inserting bolts at this time will add to the ease of their installation later.
5. Install new inducer housing assembly to heat exchanger cell panel by aligning guide pins in collector box.
6. Tighten 4 bolts securing inducer housing assembly to heat exchanger cell panel.
7. Remove screw securing capacitor and reuse to secure pressure switch and capacitor to inducer motor mounting cover plate.
8. Reconnect pressure switch tubes. See tubing label on furnace for proper connections.
a. Connect tube from burner enclosure and gas valve to
pressure switch.
b. Connect tube from collector box to pressure switch.
9. Reconnect motor leads to quick-connect.
10. Reconnect drain tube to inducer motor mounting cover plate.
12. Reinstall manifold assembly with gas valve to burner box. Replace mounting screws.
13. Replace burner box cover.
14. Using backup wrench, reconnect gas supply pipe to gas valve to prevent rotation and improper orientation.
NOTE: Use propane gas resistant pipe dope to prevent gas leaks. DO NOT use Teflon tape.
Gas valve switch or knob MUST be facing forward or tilted upward. Failure to follow this warning could result in property damage, personal injury, or death.
16. Turn on gas and electrical supplies to unit.
17. Check for gas leaks.
Never use matches, candles, flame, or other sources of ignition to check for gas leakage. Use a soap-and-water solution. Failure to follow this warning could result in a fire, personal injury, or death.
18. Check furnace operation through 2 complete cycles.
19. Reinstall main furnace door.
Copyright 1996 Carrier Corporation 340m4024
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4 Tab 6a 8a
PC 101 Catalog No. 565-826 Printed in U.S.A. Form 58M-39SI Pg 2 11-96 Replaces: 58M-37SI