UPC SERIES CONTROLLER SPECIFICATIONS
Range: 15 to 1,200 Hz
Resolution: 4 significant digits,
eg. 50.00, 400.0, etc.
Accuracy: ±0.01%, 15 to 1,200 Hz
Range: 0 to V
MAX
in 0.1 VAC steps
Accuracy: Executive voltage is within ±50 mVAC
(0.05%) of command voltage referenced to
the internal voltmeter with CSC engaged.
Dynamic output impedance (Z
o
) is programmable,
±Z
o,
MAX
in 0.1% steps. Zovalue in milliohms and range
varies with the different models but usually results in a
±10% change in output voltage at maximum rated load
current. (Optional on UPC-1, UPC-3)
Phase Separation of Phases B and C are programmable
0 to 360° relative to phase A on the UPC-3 controller.
Phase separation is fixed at 120° and 240°, respectively,
on the UPC-3M controller.
Programmable Current limit is provided on the UPC-1 and
the UPC-3 controllers. Programmable range is from
0 to I
PEAK, MAX
of the power source.
Accuracy is ± 3.0%
Resolution is ± 0.05%
The UPC-1 and UPC-3 controllers contain waveform
libraries which store 22 executable waveforms in NonVolatile RAM. Waveforms are editable via the front panel
or bus command.
Provides waveform creation by entering the magnitude
(% of fundamental) and phase angle for the 2
ND
through
the 51
ST
harmonics. (optional UPC-1 and UPC-3)
Reports voltage and waveform harmonic content as a %
of the fundamental and phase angle for the 2
ND
through
the 51
ST
harmonics. Harmonic distortion (THD, EHD, and
OHD) displayed in %. (optional on the UPC-1 and UPC-3)
The Output Voltmeter is true RMS reading and each
phase is measured independently. Line to neutral and line
to line voltages are displayed.
Range: 0-354 VAC
L-N
, 0-708 VAC
L-L
.
Resolution: 0.1 VAC to front panel, 0.001 VAC to
remote interface.
Accuracy: ±0.2% of range + cal. ref.
Output Ammeter is true RMS reading and each phase is
measured independently. RMS and peak currents along
with Crest factor are displayed.
Range: 300% of system current rating.
Resolution: 0.01 A
AC
to front panel, 0.001 AACto
remote interface.
Accuracy: ±0.2% of range + cal ref.
Measures True Power (kW), Apparent Power (kVA) and
power factor.
Range: Based on ammeter.
Resolution: 1.0 watts or VA to front panel.
1.0 watts or VA to remote interface.
Calculated and displayed to three significant digits.
Calculated and displayed to three significant digits.
Each phase is algebraically summed with UPC waveform
and amplified 25x to the direct coupled output.
±10 VDC input for each phase modulates the output
voltage ±100%.
TTL signals are provided to synchronize external test
equipment to the power source output.
1. Zero Crossing, Phase A.
2. Transient Pedestal - gate signal which is true during
the entire transient event.
3. DRM-High speed clock which is a multiple of the
fundamental output frequency used to synchronize
sub-cycle events.
The latest additions to Pacific’s SMARTSOURCE™ family of UPC Controllers are the UPC-1M, UPC-3M, UPC-1 and UPC-3. The
UPC Controller is a modular component of the ASX Series and is available in four configurations ranging from 1 Phase to 3
Phase and Manual Control to Programmable Control. The table below lists each model according to key features.
All UPC Controllers include precise metering functions with data displayed via a 160 character LCD display. This, along with
the 30-key front panel, provides the industry’s most powerful and user-friendly controller.
The UPC-1 and UPC-3 controllers are available with either the RS-232 or GPIB remote interface. Commands are structured
in accordance with SCPI (Standard Commands for Programmable Instruments). The RS-232 serial port operates up to 38.4
Bps. The GPIB interface is compatible with the IEEE-488.2.
7
FREQUENCY:
VOLTAGE:
PROGRAMMABLE
OUTPUT
IMPEDANCE:
PHASE ANGLE:
PROGRAMMABLE
CURRENT LIMIT:
WAVEFORM
LIBRARY:
WAVEFORM
SYNTHESIS:
WAVEFORM
ANALYSIS:
OUTPUT
VOLTMETER:
OUTPUT
AMMETER:
POWER:
POWER FACTOR:
CREST FACTOR:
EXTERNAL INPUTS:
AM INPUTS:
SYNC OUTPUTS: