Pacific energy GESM.BODYA, ESTEEM, ESTATE, GEST.BODYA Operating Instructions Manual

INSTALER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical Switch. Do not use any phone in your building. Immediately call your gas supplier
from a neighbour’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas supplier
cal the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket permanently located, manufacture home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is suitable for installation in a bedroom or bed sitting room.
ESTEEM & ESTATE INSTALLATION AND OPERATING INSTRUCTIONS
MODEL: GESM.BODYA & GEST.BODYA ZERO CLEARANCE FIREPLACE
020813 GESM.BODYA / GEST.BODYA 5056.412
Important Note for the Commonwealth of Massachusetts:
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fuelled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed, in addition, the installing plumber or gas fitter shall observe that a battery operated or hard-wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fuelled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)(a) 1 through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved
side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identifies “special venting systems”, the following
requirements shall be satisfied by the manufacturer.
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e)) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
2
Table of Contents
Caution 4 Safety 5
Owners Information
First Fire 6 Remote Control Operation 7 Maintenance 13 Lighting Instructions 14
Installer information
Fireplace Dimensions 15 Clearances to Combustibles 16 Locating the Fireplace 17
Surround Installation..........................................18
Venting 19
Venting Components..........................................21
Plumbing and Electrical 22 Gas Supply 23 Gas Pressure Check 23 Gas Pressure Testing Procedure 24 Pilot Adjustment 24 Propane Conversion 25 Door Installation / Removal 26 Fan Installation/ Removal 26 Panel Installation/Removal 27 Log Burner Kit Installation/Removal 28 Log Set Installation/Removal 29 Glass Burner Kit Installation/Removal 30 Intake Air Shutter Adjustment 31 Replacement Parts 32 Aesthetic Options 32 Wiring Diagram 33 Installation Notes 34
3
FOR YOUR SAFETY
- Do not install or operate your Pacific Energy fireplace without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Pacific Energy Warranty and may prove hazardous.
This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Do not use the fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.
Caution
This fireplace is equipped with a micro mesh safety screen for your protection and must be installed with the unit. Removal of the safety screen will cause the fireplace to become a burn and fire hazard.
4
Due to high temperatures, this gas appliance should be located out of traffic and away
from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and
should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the
appliance. Toddlers, young children and others may be susceptible to accidental contact burns.
A physical barrier is provided if there are at risk individuals in the house. To restrict access
to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
Clothing or other flammable material should not be placed on or near the appliance.
A barrier designed for to reduce the risk of burns from the hot viewing glass is provided
with the appliance and shall be installed.
If the barrier becomes damaged, the barrier shall be replaced with the manufacture’s
barrier for this appliance.
Any grill, panel or door removed for servicing the unit must be replaced prior to operating.
Installation and repair should be done by a qualified service person. The appliance should
be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
This appliance must not be connected to a chimney flue serving a separate solid fuel
burning appliance.
It is our policy that no responsibility is assumed by the Company or by any of its
employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures.
Safety
5
OWNER’S
INFORMATION
Congratulations on your purchase of a Pacific Energy Gas Fireplace. Your fireplace has been professionally installed by: Dealer name: ___________________ Phone Number: _________________ If you discover any problems with you gas fireplace contact you dealer immediately to have the
unit repaired. Caution: Do not attempt to repair the fireplace, you may cause injury to yourself or others, and risk
causing damage to the unit. Before operating your fireplace carefully read this manual and pay close attention to all Safety
Warnings. The manual contains important information on the unit’s safe operation and maintenance.
When lit for the first time, the fireplace will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants, gaskets, and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate the area. Odour caused by the curing process may cause discomfort to some individuals.
It is normal for fireplaces fabricated from steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or cook stove oven.
First Fire
6
OWNER’S
INFORMATION
Remote Control Operation
System Description
The Proflame Remote Control System consists of two elements:
1. Proflame Transmitter.
2. Proflame Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC to the gas valve and stepper motor.
Transmitter (Remote Control with LCD Display)
The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display (Fig. 1). The transmitter is powered by 3 AAA type batteries. A Mode key is provided to Index between the features and a Thermostat key is used to turn on/off or index through thermostat functions (Fig. 1 & 2).
Figure 1: Proflame Transmitter
Figure 2: Transmitter LCD display
`
7
OWNER’S
INFORMATION
OPERATING PROCEDURE
Initializing the System for the first time
Install the 4 AA batteries into the battery bay. Note the polarity of the battery and insert into the battery holder as indicated on the Battery cover (+/-). Set the main ON/OFF and the CPI/IPI switch in the closed position. Press the SW1 button on the IFC module. The IFC will “beep” three (3) times to indicate that it is ready to synchronize with a Transmitter. Install the 3 AAA type batteries in the battery bay, located on the base of the Transmitter. With the batteries already installed in the
Transmitter, push the ON button. The Receiver will “beep” four times to indicate the Transmitter’s
command is accepted. If a second Transmitter must be registered it can be turned ON. The receiver will beep again four (4) times and exit the synchronization phase. If only one transmitter is used, then press again the button SW1 to exit the synchronization phase. The system is now initialized.
IFC Module
The Proflame 2 Integrated Fireplace Control (IFC) board is a device that allows the automatic ignition and pilot flame supervision, to command the functions of a hearth appliance, see fig.3. It’s configured to control the ON/OFF main burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI (continuous pilot ignition) modes. The Proflame 2 IFC board controls and connects directly to the pilot assembly and an automatic valve of the Proflame 880, 886 and 885 families using low electric power.
The IFC Board can be powered by an AC and battery pack for back up (ATMO Systems only). The Proflame 2 offers the added ability to control the comfort fan speed from OFF through six (6) speeds, a remotely actuated auxiliary outlet and a dimmable light outlet. The external batteries can provide DC power to the IFC allowing the batteries to be used only when line power is interrupted or lost, and if the appliance does not use a combustion fan.
8
OWNER’S
INFORMATION
Temperature indication Display
With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of the Room Temperature display. (Fig. 3 & 4)
Turn on the Appliance
First close the main ON/OFF switch on the wirings. With the system OFF, press the ON/OFF Key on the Transmitter. The Transmitter display will show all active Icons on the screen. At the same time IFC will be commanded to start the ignition process. Once the pilot flame is proven the IFC board will open the main valve outlet and the appliance main burner will also ignite. A single “beep” from the IFC module will confirm reception of the command.
Turn off the Appliance
With the system ON, press the ON/OFF Key on the Transmitter. The Transmitter LCD display will only show the room temperature. At the same time the IFC will be commanded to turn off the burner. Depending on the system mode (IPI or CPI) the pilot may shut off (IPI) or remain lit (CPI) and the appliance burner turns OFF. A single “beep” from the Receiver confirms reception of the command.
Manual Bypass of the Remote System
If the batteries of the receiver or transmitter are low or depleted, the appliance can be turned off manually using switch located on battery box. This will bypass the remote control feature of the system.
Key Lock
This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP keys at the same time (fig.5). To de-activate this function, press the MODE and UP keys at the same time.
Figure 3: Display in Fahrenheit
Figure 4: Display in Celsius
Figure 5
9
OWNER’S
INFORMATION
Remote Flame Control
The Proflame has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the down arrow key once will reduce the flame height by one step until the flame is turned off.
The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is pressed while the system is on but the flame is off, the flame will come on in the high position. (Fig. 6)
A single “beep” will confirm reception of the command.
ROOM THERMOSTAT (Transmitter Operation)
The Remote Control can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in a room. To activate this function, press the Thermostat key (Fig. 1). The LCD display on the transmitter will change to show that the room thermostat is “ON” and the set temperature is now displayed (Fig.7). To adjust the set point, press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the transmitter.
Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point and the room temperatures. As the room temperature gets closer to the set point the Smart Function will modulate the flame down. If the room temperature is cool the Smart function will modulate the flame up. To activate this function, press the THERMOSTAT key (Fig. 1) until the word "SMART" appears to the right of the temperature bulb graphic (Fig. 8). To adjust the set point, press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the transmitter (Fig. 9).
Figure 6:
Figure 7
Figure 8: Smart Flam
Function
Figure 9
10
OWNER’S
INFORMATION
Comfort Fan Speed Control
If the appliance is equipped with a hot air circulating fan, the speed of the fan can be controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key (fig.1) to index to the fan control icon (Fig. 10). Use the Up/Down Arrow Keys (Fig.1) to turn on, off or adjust the fan speed (fig. 10). A single “beep” will confirm reception of the command.
Continuous Pilot/Intermittent Pilot (CPI/IPI) selection
With the system in "OFF" position press the Mode Key (fig. 1) to index to the CPI mode icon (fig.11). Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode (CPI). Pressing the Down Arrow Key will return to IPI. A single “beep” will confirm the reception of the command.
Figure 10: Fan Control
Figure 11: CPI/IPI Selection
11
Loading...
+ 25 hidden pages