Pacific energy FP30 Arch Craftsman Installation Instructions Manual

IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER. PLEASE SAVE THESE INSTRUCTIONS.
SAFETY NOTICE
If this stove is not properly installed, a house fire may result. For your safety, follow the instal­lation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
INSTALLATION INSTRUCTIONS
Visit www. pacificenergy.net for the most up-to-date version of this manual
240417-16 FP30 Arch Craftsman 5055.5154
FP30 ARCH CRAFTSMAN SURROUND
For use only on MODEL: FP30AR Series B
TABLE OF CONTENTS
SAFETY NOTICE: ...................................................................... 3
CLEARANCES ........................................................................... 4
ASSEMBLY - INSTALLATION .................................................... 6
Fireplace Installation into the Chase .................................. 6
Removing the Upper and Lower Grill assemblies: ............. 6
Mounting the Side Brackets ............................................... 6
Attaching the front wall Board. .......................................... 7
CHASE INLET ............................................................................ 8
Installing the Top Brow Mount and Upper Grill .................. 9
Attaching the lower grill ................................................... 10
DECORATIVE FINISH ON THE FRONT ................................... 11
Raised Hearth .................................................................. 11
INSTALLING THE FRONT ........................................................ 12
PARTS ..................................................................................... 13
IMPORTANT READING
This Accessory Face can only be used on an FP 30 ARCH Series B Wood Fireplace.
This manual is to be used in with your FP 30 AR Series B Owners Manual.
This manual covers the clearances, assembly and installation specic to this optional surround. Installation of the replace into the chase and venting is covered in the FP 30 AR Series B Owners Manual. and must be followed for safe operation. This manual supperceeds any clearances or requirements for chase air inlet written in the FP30 AR series B manual.
This Installation requires the use of a chase air inlet to supplement the air required for both natural and forced convection through the unit.
The Top Brow Mount and Side Brackets must be in place before placing the non-combustible board on the front of the replace.
FP30 Arch Craftsman 240417-16
2
5055.5154-A
WE STRONGLY RECOMMEND THAT SMOKE DETECTORS BE INSTALLED.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
You may notice that your smoke detector goes off shortly after replace installation. This may be due to the initial curing of stove paint or fumes caused by accidentally leaving the re door open. Do not disconnect the detectors. This Fireplace is not designed to be operated with the door open. Open the door for loading only.
SAFETY NOTICE:
If this stove is not properly installed, a house re may result. For your safety, follow the installation instruc­tions. Contact local building or re ofcials about restrictions and installation inspection requirements in your area.
Read this entire manual and the FP30 AR Series B Owners Manual before you install and use your new room heater. Failure to follow the instructions in this manual and those in the FP30 AR Series B Owners Manual, may result in property damage, bodily injury, or even death.
5055.5154-A
3
FP30 Arch Craftsman 240417-16
CLEARANCES
B
B
C
A
B
I
F
G
E
H
D
Figure 1: FP30.Body B Arch Surround - Clearance.
Fireplace Clearances (Figure 1)
A Minimum distance from top of the Arch to 4” [100mm] deep combustible mantel 14” (355mm) B Minimum distance from base of the replace to 4” [100mm] deep combustible mantel 51 3/4” (1.315m) C Minimum distance from top of the Arch to 12” [305mm] deep combustible mantel 22” (560mm) D Minimum distance from base of the replace to 12” [305mm] deep combustible
mantel
E Minimum distance from the sides of the replace door to Mantle Pillars/Legs (max. 3
1/2” [90mm]deep) F Minimum distance between the Mantle Pillars/Legs (max. 3 1/2” [90mm]deep) 47 1/2” (1.205m G Minimum distance from a Side Wall to the side of the replace door 29” (735mm) H Minimum distance from the base of the replace to the ceiling 84” (2.135m) ** Minimum depth of (UL1618 Class 1) non-combustible Ember Protection from the front
of the replace L Minimum width of (UL1618 Class 1) Ember Protection: In Canada
:In U.S.A.
59 3/4” (1.52m)
10” (255mm)
18” (460mm)
58” (1.47m) 39”
FP30 Arch Craftsman 240417-16
4
5055.5154-A
C
A
Graduated Mantle (Figure 1b)
Depth Height from top of arch Height from bottom of unit 4”(102mm) 14”(355mm) (A) 51 3/4”(1.315m) (B) 5”(127mm) 52 3/4”(1.34m) 6”(150mm) 16”(406mm) 53 3/4”(1.365m) 7”(178mm) 54 3/4”(1.391m) 8”(203mm) 18”(457mm 55 3/4”(1.416m) 9”(229mm) 56 3/4”(1.441m) 10”(254mm) 20”(508mm) 57 3/4”(1.467m) 11”(279mm) 58” 3/4”(1.492m) 12”(305mm) 22”(560mm) (C) 59 3/4”(1.518m) (D)
Figure 2: Mantel clearances.