Pacific energy Installation And Operating Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: If the information in these
instructions is not followed exactly a fire
or explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electrical Switch.
•Do not use any phone in your building.
•Immediately call your gas supplier from
a neighbour’s phone. Follow the gas
supplier’s instructions.
•If you cannot reach your gas supplier
call the fire department.
Installation and service must be per formed
by a qualified installer, service agency or
the gas supplier.
ESTEEM / ESTATE
INSTALLATION AND
OPERATING INSTRUCTIONS
This appliance may be installed in an aftermarket permanently located, manufactured home
(USA only) or mobile home, where not prohibited
by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance is not convertible for use with other gases
unless a certified kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
010317-44
ESTM.BODYB
ESTT.BODYB
MODEL: ESTEEM / ESTATE
SERIES: B
DIRECT VENT FIREPLACE
Important Note for the Commonwealth of Massachusetts
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential
purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet
above nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satised.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the
installing plumber or gas tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the oor
level where the gas equipment is to be installed, in addition, the installing plumber or gas tter shall observe that a battery operated or hard-wired
carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal
vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualied licensed professionals for the
installation of hard-wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide
detector with alarm and battery back-up may be installed on the next adjacent oor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty
(30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide
detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall
comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet
above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall
read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless,
upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)
(a) 1 through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the
Board; and
2. Product Approved side wall horizontal vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure
used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided
by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved
side wall horizontally vented gas fueled equipment does not provide the parts for venting the fuel gases, but identies “special venting systems”, the
following requirements shall be satised by the manufacturer.
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed
installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts
lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
ESTM.BODYB
ESTT.BODYB
010317-44
3
5056.412-B
Caution
FOR YOUR SAFETY
understanding this manual. Any installation or operational deviation from the following instructions voids the
Pacic Energy Warranty and may prove hazardous.
This appliance and its individual shut off valve must be disconnected from gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2
psi (3.5 kPa).
Do not use the replace if any part has been under water. Immediately call a qualied service technician to
inspect the replace and to replace any part of the control system and any gas control which has been under
water.
- Do not install or operate your Pacic Energy replace without rst reading and
This fireplace is equipped with a micro mesh safety screen for your protection and
must be installed with the unit. Removal of the safety screen will cause the fireplace
to become a burn and fire hazard.
5056.412-B
4
010317-44
ESTM.BODYB
ESTT.BODYB
Safety
• Due to high temperatures, this gas appliance should be located out of trafc and away from furniture and
draperies.
• Children and adults should be alerted to the hazards of high surface temperatures and should stay away
to avoid burns or clothing ignition.
•Young children should be carefully supervised when they are in the same room as the appliance. Toddlers,
young children and others may be susceptible to accidental contact burns.
• A physical barrier is provided if there are at risk individuals in the house. To restrict access to a replace or
stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of
the room and away from hot surfaces.
• Clothing or other ammable material should not be placed on or near the appliance.
• A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and shall be installed.
• If the barrier becomes damaged, the barrier shall be replaced with the manufactures’ barrier for this
appliance.
• Any grill, panel or door removed for servicing the unit must be replaced prior to operating.
• Installation and repair should be done by a qualied service person. The appliance should be inspected
before use and at least annually by a professional service person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments,
burners and circulating air passageways of the appliance be kept clean.
•This appliance must not be connected to a chimney ue serving a separate solid fuel burning appliance.
• It is our policy that no responsibility is assumed by the Company or by any of its employees or
representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the
result, either directly or indirectly, of any improper operation or installation procedures.
ESTM.BODYB
ESTT.BODYB
010317-44
5
5056.412-B
Congratulations on your purchase
of a Town & Country Fireplace
Your zero-clearance Fireplace has been professionally installed by:
If you discover any problems with your Fireplace contact your dealer immediately to have the unit repaired.
Caution: Do not attempt to repair the Fireplace because you may cause injury to yourself or others, and risk
causing damage to the unit.
Before operating your Fireplace carefully read this manual and pay close attention to all Safety
Warnings. The manual contains important information on the unit’s safe operation and maintenance.
First Fire
When lit for the rst time, the replace will emit a slight odour for a couple of hours. This is due to the curing
of paints, sealants, gaskets, and lubricants used in the manufacturing process. This condition is temporary.
Open doors and windows to ventilate the area. Odour caused by the curing process may cause discomfort
to some individuals.
It is normal for replaces fabricated from steel to give off some expansion and/or contraction noises during
the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or cook stove
oven.
NOTE: Fireplace may take up to 30 seconds to ignite
each time the “ON” button has been selected
Warnings and Cautions
WARNING
Fire Hazard. Can cause severe injury or death
The Receiver causes ignition of the appliance. The appliance can turn on suddenly. Keep away from the
appliance burner when operating the remote system or activating manual bypass of the remote system.
WARNING
Shock Hazard. Can cause severe injury or death
This device is powered by line voltage. Do not try to repair this device. In no way is the enclosure to be
tampered with or opened. Disconnect from line voltage before performing any maintenance.
5056.412-B
6
010317-44
ESTM.BODYB
ESTT.BODYB
Remote Control Operation
System Description
The Pro ame 2 Remote Control System consists of two elements:
1. Pro ame 2 Transmitter.
2. Pro ame 2 Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC.
Transmitter (Remote Control with LCD Display)
The Pro ame 2 Transmitter uses a streamline design with a simple button layout and informative LCD
display (Figure 1). The transmitter is powered by 3 AAA type batteries. A Mode key is provided to Index
between the features and a Thermostat key is used to turn on/off or index through thermostat functions
(Figure 1 and Figure 2) .
Blue back lit LCD display
ON/OFF Key
THERMOSTAT Key
UP/DOWN Arrow Key
MODE Key
ESTM.BODYB
ESTT.BODYB
Figure 1: Pro ame 2 handset.
TRANSMISSION
THERMOSTAT OFF/
ON/SMART
SET POINT:
TEMPERATURE/LEVEL/STATE
DIMMER ON
COMFORT FAN
Figure 2: Pro ame 2 LCD display.
010317-44
MAXMAX
OFF
ON
SMART
KEY LOCK
LOW BATTERY ALARM
ROOM
TEMPERATURE
CPI MODE
7
5056.412-B
IFC Module
The Proame2 Integrated Fireplace Control (IFC) module (Figure 3) is a device that allows automatic ignition
and pilot ame supervision, and commands the functions of the hearth Fireplace. It’s congured to control
the ON/OFF main burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI (continuous pilot ignition) modes. The Proame2 IFC module controls and connects directly to the pilot assembly and
the automatic valve using low electric power.
The IFC module can be powered by both an AC power supply, and battery pack for back up. The Proame2
offers the added ability to control the comfort fan speed from OFF through six (6) speeds, a remotely actuated
auxiliary outlet and a dimmable light outlet. The external batteries can provide DC power to the IFC allowing
the batteries to be used only when line power is interrupted or lost, and if the Fireplace does not use a
combustion fan.
Operating Procedure
Initializing the System for the first time
1. Install 4 AA batteries into the battery bay (Figure 4) located on the rear side behind the surround below the
rebox. Install the ON/OFF switch cover (Figure 5) over top of the battery bay. Make sure that the selection
switch is on the “Remote” setting.
2. Install 3 AAA batteries into the Proame2 Remote Transmitter (Figure 1).
3. Plug the power cord into the Brentwood/Broadway and open the gas supply line.
4. Insert a straightened paper clip into the opening marked “PRG” of the ON/OFF battery bay cover
(Figure 5) and press the program button once. The module will beep 3 times indicating that it is ready to
synchronize with a remote transmitter.
5. On the remote transmitter, push the power on button once. The remote transmitter will beep 4 times to
indicate that the remote transmitter and the control module are now synchronized. The remote transmitter is
now ready to use.
With the system in the “OFF” position, press the Thermostat Key
and the Mode Key at the same time. Look at the LCD screen on the
transmitter to verify that a C or F is visible to the right of the Room
Temperature display (Figure 6 and Figure 7).
Turn on the Fireplace
With the system OFF, press the ON/OFF Key on the remote transmitter.
The remote transmitter display will show some other active Icons on
the screen. At the same time the Receiver will activate the Heater. A
single “beep” from the Receiver (module) will conrm reception of the
command.
Turn off the Fireplace
With the system ON, press the ON/OFF Key on the Remote transmitter.
The Remote transmitter LCD display will only show the room tempera-
ture (Figure 6 and Figure 7). At the same time the Receiver (module) will
turn off the Heater. A single “beep” from the Receiver conrms reception of the command.
Figure 6: Temperature in
fahrenheit.
C
Manual Bypass of the Remote System
If the batteries of the receiver or remote transmitter are low or depleted,
the Heater can be turned off manually using ON/OFF switch located on
battery box at the rear of the Broadway/Brentwood. This will bypass
the remote transmitter.
Key Lock
This function will lock the keys to avoid unsupervised operation. To acti-
vate this function, press the MODE and UP keys at the same time. The
lock icon will appear (Figure 8). To de-activate this function, press the
MODE and UP keys at the same time.
Figure 7: Temperature in celcius.
Figure 8: Key lock icon.
ESTM.BODYB
ESTT.BODYB
010317-44
9
5056.412-B
Remote Flame Control
The Proame has six (6) ame levels. With the
system on, and the ame level at the maximum
in the appliance, pressing the down arrow key
once will reduce the ame height by one step
until the ame is turned off.
The Up Arrow Key will increase the ame height
each time it is pressed. If the Up Arrow Key is
pressed while the system is on but the ame is
off, the ame will come on in the high position
(Figure 9). A single “beep” will conrm reception
of the command.
Flame level Max
Flame level 5
Room Thermostat (Transmitter Operation)
The Remote Control can operate as a room thermostat. The
thermostat can be set to a desired temperature to control the
comfort level in a room.
To activate this function, press the Thermostat key (Figure 1).
The LCD display on the transmitter will change to show that
the room thermostat is “ON” and the set temperature is now
displayed (Figure 10). To adjust the set point, press the up or
down arrow keys until the desired set point temperature is
displayed on the LCD screen of the transmitter.
Flame level 1
Figure 9: Flame level control.
Room Temperature
Set Temperature
Figure 10: Room temperature control.
Flame Off
5056.412-B
10
010317-44
ESTM.BODYB
ESTT.BODYB
Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the ame height in accordance to the difference between the set
point and the room temperatures. As the room temperature gets closer to the set point, the Smart Function
will modulate the ame down. If the room temperature is cool, the Smart Function will modulate the ame up.
To activate this function, press the THERMOSTAT key (Figure 1) until the word “SMART” appears to the right
of the temperature icon (Figure 11). To adjust the set point, press the up or down arrow keys until the desired
set point temperature is displayed on the LCD screen of the remote transmitter (Figure 12).
Figure 11: Smart ame control.
Figure 12: Smart ame function
set low.
Comfort Fan Speed Control
If the Heater is equipped with a hot air circulating fan, the speed of the fan can be controlled by the Pro ame
2 System. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key
(Figure 1) to index to the fan control icon (Figure 13). Use the Up/Down Arrow Keys to turn on, off or adjust
the fan speed (Figure 14). A single “beep” will con rm reception of the command.
Figure 13: Comfort fan HI.
ESTM.BODYB
ESTT.BODYB
Figure 12
010317-44
Figure 14: Comfort fan off.
11
5056.412-B
Continuous Pilot/Intermittent Pilot (CPI/IPI) selection
With the system in the “OFF” position, press the Mode Key (Figure 1) to index to the CPI mode icon
(Figure 15). Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode (CPI). Pressing the
Down Arrow Key will return to IPI (Figure 16). A single “beep” will con rm the reception of the command.
Figure 15: CPI Mode.Figure 16: IPI Mode.
Low Battery Power Detection
Transmitter
The life span of the remote control batteries depends on various factors: quality of the batteries used, the
number of ignitions of the Heater, the number of changes to the room thermostat set point, etc.
When the remote batteries are low, an icon will appear on the LCD display of the remote (Figure 17) before all
battery power is lost. When the batteries are replaced this icon will disappear.
Receiver
The life span of the IFC module batteries depends on various factors: quality of the batteries used, the
number of ignitions of the Heater, the number of changes to the room thermostat set point, etc.
When the IFC batteries are low, a “double-beep” will be emitted from the IFC module when it receives a
command from the remote. This is an alert for a low battery condition for the IFC board. When the batteries
are replaced, a single “beep” will be emitted from the IFC module when a key is pressed. See “Initializing the
System for the rst time” on page 8
Figure 17: Low battery indication.
5056.412-B
12
010317-44
ESTM.BODYB
ESTT.BODYB
Maintenance
CAUTION:
Turn off gas and electrical power supply (if applicable) and allow ample time for unit to
cool before servicing appliance. It is recommended that the replace and its venting
should be inspected at least once a year by a qualied service person.
Glass Door:
FLAME SENSOR
PILOT
PILOT FLAME
Warning: Do not operate replace with glass panel removed, cracked or broken.
Replacement of the glass panel should be done by a licensed or qualied service
person.
Do not strike or otherwise impact the glass in anyway that may cause it to break. If
the glass becomes cracked or broken it must be replaced before using the replace.
Replacement glass can be obtained from your nearest Town & Country FireplacesTM
dealer. The size required is 52" x 16" x 5mm. Use ceramic glass only. Do not substitute
with any other type.
To remove broken glass, remove window frame as noted in See “Door Installation/
Removal” on page 28.
Unclip the Glass Retainer Clips located at the top and sides of the Window Frame. Pull
the top edge of the glass out of the frame rst, then lift it up and out of the bottom edge.
Install the new piece of glass with the gasket into the frame so that the thicker bead of
gasket faces the replace.
Re-install glass retaining clips.
Figure 18: Pilot assembly.
ELECTRODE
Annual Inspection:
a) Remove glass panel and pebble assemblies. Inspect pebble and burner assemblies for soot buildup. If excessive buildup of soot
is present, have a qualied service person inspect and adjust unit for proper combustion. Clean logs and burner with a brush or
vacuum cleaner, paying close attention to burner ports.
b) Check the pilot system for proper ame size and operation. Clean pilot free of soot, dust or any other deposits (See Figure 18).
c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If the venting is disassembled for cleaning, it
must be properly assembled and re-sealed. Refer to VENTING section for proper procedure.
d) Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good condition.
e) Check and replace batteries as needed.
Note: The appliance area must be kept clear and free from combustible materials, gasoline and other ammable vapours and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with replace glass cleaner.
b) Exterior nish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the replace.
Do not clean glass when hot.
ESTM.BODYB
ESTT.BODYB
010317-44
13
5056.412-B
5056.412-B
14
010317-44
ESTM.BODYB
ESTT.BODYB