Pacific energy Installation And Operating Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: If the information in these
instructions is not followed exactly a re
or explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other
ammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical Switch.
• Do not use any phone in your building.
• Immediately call your gas supplier
from a neighbour’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier
call the re department.
Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
This appliance may be installed in
an aftermarket permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases
unless a certied kit is used.
CASCO / CAMDEN
INSTALLATION AND
OPERATING INSTRUCTIONS
This appliance is suitable for installation in a
bedroom or bed sitting room.
210515-445055.634-B
MODEL: CASCO / CAMDEN
SERIES: B
DIRECT VENT FIREPLACES
CASC.BODYB
CMDN.BODYB
Important Note for the Commonwealth of Massachusetts:
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential
purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above
nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satised.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fuelled equipment, the
installing plumber or gas tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the oor level
where the gas equipment is to be installed, in addition, the installing plumber or gas tter shall observe that a battery operated or hard-wired carbon
monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas
fuelled equipment. It shall be the responsibility of the property owner to secure the services of qualied licensed professionals for the installation of
hard-wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide
detector with alarm and battery back-up may be installed on the next adjacent oor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty
(30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detec
tor with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply
with NFPA 720 and be ANSI/UL 2034 listed as IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet
above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment. The sign shall read, in
print size no less than one-half (1/2) inch in size, ‘‘GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS’’.
-
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless,
upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)(a) 1
through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1. The equipment listed in Chapter 10 entitled ‘‘Equipment Not Required To Be Vented’’ in the most current edition of NFPA 54 as adopted by the Board;
and
2. Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or struc
ture used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - -- GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side
wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by
the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - -- GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved
side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identies ‘‘special venting systems’’, the
following requirements shall be satised by the manufacturer.
1. The referenced ‘‘special venting system’’ instructions shall be included with the appliance or equipment installation instructions; and
2. The ‘‘special venting systems’’ shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed
installation instructions.
(e)) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all
parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
-
5055.634-B
2
210515-44
CASC.BODYB
CMDN.BODYB
Table of Contents
Important note for Massachusetts .................. 2
FOR YOUR SAFETY - Do not install or operate your Pacic Energy replace without rst reading and
understanding this manual. Any installation or operational deviation from the following instructions voids
the Pacic Energy Warranty and may prove hazardous.
This appliance and its individual shut off valve must be disconnected from gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut
off valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 1/2 psi (3.5 kPa).
Do not use the replace if any part has been under water. Immediately call a qualied service technician
to inspect the replace and to replace any part of the control system and any gas control which has been
under water.
This replace is equipped with a micro mesh safety screen for your protection and
must be installed with the unit. Removal of the safety screen will cause the replace
to become a burn and re hazard.
5055.634-B
4
210515-44
CASC.BODYB
CMDN.BODYB
Safety
INFORMATION
• Due to high temperatures, this gas appliance should be located out of traffic and away from
furniture and draperies.
• Children and adults should be alerted to the hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
• Young children should be carefully supervised when they are in the same room as the
appliance. Toddlers, young children and others may be susceptible to accidental contact
burns.
• A physical barrier is provided if there are at risk individuals in the house. To restrict access to a
replace or stove, install an adjustable safety gate to keep toddlers, young children and other
at risk individuals out of the room and away from hot surfaces.
• Clothing or other ammable material should not be placed on or near the appliance.
OWNER’S
• A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
• If the barrier becomes damaged, the barrier shall be replaced with the manufactures’ barrier for
this appliance.
• Any grill, panel or door removed for servicing the unit must be replaced prior to operating.
• Installation and repair should be done by a qualied service person. The appliance should be
inspected before use and at least annually by a professional service person. More frequent
cleaning may be required due to excessive lint from carpeting, bedding material, etc. It
is imperative that control compartments, burners and circulating air passageways of the
appliance be kept clean.
• This appliance must not be connected to a chimney ue serving a separate solid fuel burning
appliance.
• It is our policy that no responsibility is assumed by the Company or by any of its employees or
representatives for any damages caused by an inoperable, inadequate, or unsafe condition
which is the result, either directly or indirectly, of any improper operation or installation
procedures.
CASC.BODYB
CMDN.BODYB
210515-44
5
5055.634-B
OWNER’S
INFORMATION
Congratulations on your purchase of a Pacic Energy Gas Fireplace.
Your replace has been professionally installed by:
Dealer name: _____________________________
Phone Number: ___________________________
If you discover any problems with your gas replace contact your dealer immediately to have the
unit repaired.
Caution: Do not attempt to repair the replace yourself, you may cause injury to yourself or others
and risk causing damage to the unit.
Before operating your replace, carefully read this manual and pay close attention to all Safety
Warnings. The manual contains important information on the unit’s safe operation and mainte-
nance.
First Fire
When lit for the rst time, the replace will emit a slight odour for a couple of hours. This is due
to the curing of paints, sealants, gaskets, and lubricants used in the manufacturing process. This
condition is temporary. Open doors and windows to the ventilate area. Odour caused by the curing
process may cause discomfort to some individuals.
It is normal for replaces fabricated from steel to give off some expansion and/or contraction
noises during the start up or cool down cycle. Similar noises are found with your furnace heat
exchanger or cook stove oven.
NOTE: Fireplace may
take up to 30 seconds
to ignite each time the
“ON” button has been
5055.634-B
selected
6
210515-44
CASC.BODYB
CMDN.BODYB
Remote Control Operation
`
INFORMATION
System Description
OWNER’S
The Proame2 Remote Control System consists of two elements:
1. Proame2 Transmitter.
2. Proame2 Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC to the
gas valve and stepper motor.
Transmitter (Remote Control with LCD Display)
The Proame2 Transmitter uses a streamline design with a simple button layout and informative LCD display
(Fig. 1). The transmitter is powered by 3 AAA type batteries. A Mode key is provided to Index between the
features and a Thermostat key is used to turn on/off or index through thermostat functions (Fig. 1 & 2).
CASC.BODYB
CMDN.BODYB
210515-44
Figure 1: Proame Transmitter
Figure 2: Transmitter LCD display
7
5055.634-B
OWNER’S
INFORMATION
IFC Module
The Proame2 Integrated Fireplace Control (IFC) module (Fig. 3) is a device that allows automatic ignition
and pilot ame supervision, and commands the functions of the hearth Fireplace. It’s congured to control
the ON/OFF main burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI
(continuous pilot ignition) modes. The Proame2 IFC module controls and connects directly to the pilot
assembly and the automatic valve using low electric power.
The IFC module can be powered by both an AC power supply, and battery pack for back up. The Proame2
offers the added ability to control the comfort fan speed from OFF through six (6) speeds, a remotely
actuated auxiliary outlet and a dimmable light outlet. The external batteries can provide DC power to the IFC
allowing the batteries to be used only when line power is interrupted or lost, and if the Fireplace does not
use a combustion fan.
Operating Procedure
Initializing the System for the rst time
1. Install 4 AA batteries into the battery bay (Fig. 4) located on the rear side behind the surround below
the rebox. Install the ON/OFF switch cover (Fig. 5) over top of the battery bay. Make sure that the
selection switch is on the “Remote” setting.
2. Install 3 AAA batteries into the Proame2 Remote Transmitter (Fig. 1).
3. Plug the power cord into the Brentwood/Broadway and open the gas supply line.
4. Insert a straightened paper clip into the opening marked “PRG” of the ON/OFF battery bay cover
(Fig. 4 & 5) and press the program button once. The module will beep 3 times indicating that it is
ready to synchronize with a remote transmitter.
5. On the remote transmitter, push the power on button once. The remote transmitter will beep 4 times
to indicate that the remote transmitter and the control module are now synchronized. The remote
transmitter is now ready to use.
Figure 4. On/Off switch. Position switch in the
middle to use the hand-held remote control
switch.
3. IFC (integrated replace
control) module.
Figure 5. On/Off switch cover
5055.634-B
8
210515-44
CASC.BODYB
CMDN.BODYB
Temperature indication Display
With the system in the “OFF” position, press the Thermostat Key and the
Mode Key at the same time. Look at the LCD screen on the transmitter to
verify that a C or F is visible to the right of the Room Temperature display.
(Fig. 6 & 7)
OWNER’S
INFORMATION
Turn on the Fireplace
With the system OFF, press the ON/OFF Key on the remote transmitter. The
remote transmitter display will show some other active Icons on the screen.
At the same time the Receiver will activate the Heater. A single “beep” from
the Receiver (module) will conrm reception of the command.
Turn off the Fireplace
With the system ON, press the ON/OFF Key on the Remote transmitter. The
Remote transmitter LCD display will only show the room temperature
(Fig. 6 or 7). At the same time the Receiver (module) will turn off the Heater.
A single “beep” from the Receiver conrms reception of the command.
Manual Bypass of the Remote System
If the batteries of the receiver or remote transmitter are low or depleted, the
Heater can be turned off manually using ON/OFF switch located on battery
box at the rear of the Broadway/Brentwood. This will bypass the remote
transmitter.
Figure 6: Display in Fahrenheit
Figure 7: Display in Celsius
Key Lock
This function will lock the keys to avoid unsupervised operation. To activate
this function, press the MODE and UP keys at the same time. The lock icon
will appear (Fig. 8). To de-activate this function, press the MODE and UP
keys at the same time.
CASC.BODYB
CMDN.BODYB
210515-44
Figure 8
9
5055.634-B
OWNER’S
INFORMATION
Remote Flame Control
The Proame2 has six (6) ame levels. With the
system on, and the ame level at the maximum in
the appliance, pressing the down arrow key once
will reduce the ame height by one step until the
ame is turned off.
The Up Arrow Key will increase the ame height
each time it is pressed. If the Up Arrow Key is
pressed while the system is on but the ame is off,
the ame will come on in the high position.
(Fig. 9) A single “beep” will conrm reception of the
command.
ROOM THERMOSTAT (Transmitter Operation)
Figure 9:
The Remote Control can operate as a room thermostat. The
thermostat can be set to a desired temperature to control the
comfort level in a room.
To activate this function, press the Thermostat key (Fig. 1). The
LCD display on the transmitter will change to show that the room
thermostat is “ON” and the set temperature is now displayed
(Fig.10). To adjust the set point, press the up or down arrow keys
until the desired set point temperature is displayed on the LCD
screen of the transmitter.
Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the ame height in
accordance to the difference between the set point and the room
temperatures. As the room temperature gets closer to the set
point, the Smart Function will modulate the ame down. If the
room temperature is cool, the Smart Function will modulate the
ame up. To activate this function, press the
THERMOSTAT key (Fig. 1) until the word “SMART” appears
to the right of the temperature icon (Fig.11). To adjust the set
point, press the up or down arrow keys until the desired set
point temperature is displayed on the LCD screen of the remote
transmitter (Fig. 12).
Figure 10
Figure 11: Smart Flame
Function
5055.634-B
10
210515-44
Figure 12
CASC.BODYB
CMDN.BODYB
OWNER’S
INFORMATION
Comfort Fan Speed Control
If the Heater is equipped with a hot air circulating fan, the speed of the fan can be
controlled by the Proame2 System. The fan speed can be adjusted through six (6) speeds.
To activate this function use the Mode Key (Fig. 1) to index to the fan control icon (Fig. 13).
Use the Up/Down Arrow Keys (Fig. 1) to turn on, off or adjust the fan speed (Fig. 13). A
single “beep” will conrm reception of the command.
Figure 13: Fan Control
Continuous Pilot/Intermittent Pilot (CPI/IPI) selection
With the system in the “OFF” position, press the Mode Key (Fig. 1) to index to the CPI
mode icon (Fig. 14). Pressing the Up Arrow Key will activate the Continuous Pilot Ignition
mode (CPI). Pressing the Down Arrow Key will return to IPI. A single “beep” will conrm the
reception of the command.
CASC.BODYB
CMDN.BODYB
210515-44
Figure 14: CPI/IPI Selection
11
5055.634-B
OWNER’S
INFORMATION
Low Battery Power Detection
Transmitter
The life span of the remote control batteries depends on various
factors: quality of the batteries used, the number of ignitions of the
Heater, the number of changes to the room thermostat set point,
etc.
When the remote batteries are low, an icon will appear on the
LCD display of the remote (Fig. 15) before all battery power is lost.
When the batteries are replaced this icon will disappear.
Receiver
The life span of the IFC module batteries depends on various factors: quality of the batteries used,
the number of ignitions of the Heater, the number of changes to the room thermostat set point,
etc.
Figure 15
When the IFC batteries are low, a “double-beep” will be emitted from the IFC module when it
receives a command from the remote. This is an alert for a low battery condition for the IFC board.
When the batteries are replaced, a single “beep” will be emitted from the IFC module when a key
is pressed (See initialization of the system for the rst time on page 8).
Warnings and Cautions
WARNING
Fire Hazard. Can cause severe injury or death
The Receiver causes ignition of the appliance. The appliance can turn on
suddenly. Keep away from the appliance burner when operating the remote
system or activating manual bypass of the remote system.
WARNING
Shock Hazard. Can cause severe injury or death
This device is powered by line voltage. Do not try to repair this device.
In no way is the enclosure to be tampered with or opened.
Disconnect from line voltage before performing any maintenance.
5055.634-B
12
210515-44
CASC.BODYB
CMDN.BODYB
Maintenance
INFORMATION
Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool
before servicing appliance. It is recommended that the replace and its venting should be
inspected at least once a year by a qualied service person.
Glass Door:
OWNER’S
Warning:
Do not operate replace with glass door removed, cracked or broken. Replacement
of the glass door should be done by a licensed or qualied service person.
Do not strike or otherwise impact the glass in any way that may cause it to break. If the glass
becomes cracked or broken it must be replaced before using the replace. Replacement door
can be obtained from your nearest Pacic Energy dealer.
Do not substitute with any
other type.
To remove broken glass, remove Door as noted in “Door Removal” section.
Annual Inspection:
a) Remove glass door and decorative media (such as logs and rocks). Inspect decorative
media and burner assemblies for soot buildup. If excessive buildup of soot is present,
have a qualied service person inspect and adjust unit for proper combustion. Clean
burners with a brush or vacuum cleaner, paying close attention to burner ports.
b) Check the pilot system for proper ame size and operation. Clean pilot free of soot, dust
or any other deposits.
c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If
the venting is disassembled for cleaning, it must be properly assembled and re-sealed.
Refer to VENTING section for proper procedure.
d) Check glass panel gasket, replace if necessary. It is important that the glass seal be
maintained in good condition.
e) Check and replace batteries as needed.
Note: The appliance area must be kept clear and free from combustible materials, gasoline
and other ammable vapors and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with replace glass cleaner.
b) Exterior nish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the replace.
Do not clean glass when hot.
CASC.BODYB
CMDN.BODYB
210515-44
13
5055.634-B
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:
A.This appliance is equipped with an ignition device which
building.
- Immediately call your gas supplier from a neighbour's phone. Follow
1. STOP! Read the safety information above on this label.
"On/ Off" switch for the fireplace to OFF, turn off all electric power
to the fireplace and call your service technic ian or gas suppl ier.
6. Set fireplace to desired setting by using hand held remote.
1.
2. Turn off all electric power to the appliance and remove backup
Due to high surface temperatures, keep children, clothing and furniture away. Keep burner and control compartment clean. See installation and
CAUTION:
090713
5051.185
GBWY
OWNER’S
INFORMATION
Lighting Instruct ions
fire or explosion may result causing property damage,
personal injury or loss of life.
If you do not follow these instructions exactly, a
automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone in your
LIGHTING INSTRUCTIONS
2. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot by hand.
3. Push the "On/ Off" switch to turn the fireplace ON.
- If the burner does light go to step 6.
- If the burner does not light, complete steps 4 through 5.
- If the burner will not light or stay lit after several tries, push the
TO TURN OFF GAS APPLIANCE
Push the "on/ off" switch to the "Off" position.
the gas supplier's instructions.
- If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don't try to repair it,
call a qualified service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance & to replace any part of the control s
control which has been under water.
Note: Sufficient time must be allowed for air to escape from lines if
the unit is being lit for the first time.
4. Push the "On/ Off" switch to the fireplace Off.
5. Allow sufficient length of time (minimum 5 minutes) for any gas in the
combustion chamber to escape. If you still smell gas, STOP! Follow
"B" in the safety information above on this label. If you don't smell
gas, go to step 3.
batteries if service is to be performed or for extended shutdown.
ystem & any gas
operating instructions accompanying the appliance.
A cause de la temperature elevee des parios, tenir eloignes les enfants, les vetements et les meubles. Maintenir propres le bruleur et le
compartiment de commande. Voir les instructions relatives a l'installation et au fonctionnement qui accompagnent l'appareil.
Hot while in operation. Do not touch. Severe burns may result. Keep children,
clothing, furniture, gasoline and other liquids having flammable vapours away. Keep burner and control
compartment clean. See installation and operating instructions accompanying the appliance.
ATTENTION:L'appareil est chaud lorsqu'il fonctionne. Ne pas toucher l'appareil. Risque de
brûlures graves. Serveiller les enfants. Garder les vêtements, le meubles, l'essence ou autres liquides
produisant des vapeurs infl ammables loin de l'appareil. S'assurer que le brûleur et le compartiment des
commandes sont propres. Voir les instructions d'installation et d'utilisation qui accompagnent l'appareil.
5055.634-B
14
210515-44
CASC.BODYB
CMDN.BODYB
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.