Pacific energy Alderlea T5 LE Insert Installation And Operating Instructions Manual

IMPORTANT:
THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS
SERIAL #
SAFETY NOTICE
If this stove is not properly installed, a house re may result. For your safety, follow the installation instructions. Contact local building or re ofcials about restrictions and installation inspection requirements in your area.
Meets the U.S. Environmental Protection Agency's May 2020 Particulate Emission Standards.
INSTALLATION AND OPERATING INSTRUCTIONS
MODELS: ALDERLEA T5 LE INSERT
Visit www.pacificenergy.net for the most recent version of this manual
230819-32 ALT5.INSERT LE 100003038-50
Table of Contents
Rating Label ...................................................................... 3
Efciency and BTU Output ........................................3
Safety ................................................................................ 4
Chimney Smoke and Creosote Formation ................4
Chimney Fires ............................................................ 4
To Avoid a Chimney Fire ............................................ 5
In Case of a Chimney Fire .........................................5
Curing of the Paint Finish ..........................................5
Disposal of Ashes ...................................................... 5
Operation ........................................................................... 6
Wood Selection..........................................................6
DO NOT BURN : ........................................................ 6
How to Test Your Wood .............................................6
Lighting a re .............................................................7
Normal Operation ......................................................7
DO NOT OVERFIRE THIS HEATER: ........................7
Convection Blower Operation ...................................8
Restarting After Extended or Overnight Burns .......... 8
Proper Draft ...............................................................8
Maintenance ...................................................................... 9
DOOR GASKETS - .....................................................9
Maintenance Checks ....................................................... 10
Weekly: ....................................................................10
Monthly .................................................................... 10
When Cleaning the Chimney System: .....................10
Blower: ..................................................................... 10
Bafe: ....................................................................... 10
Bafe Removal ................................................................ 10
Removal ................................................................... 10
Dimensions ...................................................................... 11
Minimum Fireplace and Hearth Dimensions ................... 12
Hearth Requirements: .............................................. 12
Ember Protection: .................................................... 13
Optional Leveling Legs ............................................13
Clearances ...................................................................... 14
Minimum Clearances to Combustibles: ..................14
Installation ....................................................................... 15
Fireplace Specications...........................................15
Into a Masonry Fireplace .........................................15
Full Flue Liner - (Required in Canada) ....................16
Direct Flue Connection (permitted only in the USA) 17
Into a Factory Built Fireplace ................................... 18
Combustion Air ........................................................ 18
Electrical Supply ...................................................... 19
Surround Assembly and Installation ........................ 20
Fan Speed Controller Relocation.............................22
Fan Removal/Installation .........................................25
Troubleshooting ............................................................... 26
Firebrick Installation ........................................................ 27
Replacement Parts .......................................................... 30
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacific Energy, ALDERLEA T5 INSERT LE; Fireplace Insert wood heater. Please read this entire manual before you install and use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or even death.
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leaving the re door open. Do not disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in you area.
Attention Residents of California:
WARNING: this product can expose you to chemicals including ceramic bers, which are known
to the state of California to cause cancer, and to carbon monoxide, which is known to the state of California to cause birth defects or other reproductive harm.
For more information go to www.p65warnings.ca.gov.
100003038
This warning is applicable to all
PACIFIC ENERGY FIREPLACE PRODUCTS
2
ALT5 LE Insert 230819-32
Rating Label
260419 SUPER INSERT LE 100002100
1.8 g/hr
This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 16,102 to 41,275 Btu/hr.
D
C# 4001507
SUPER INSERT LE ALDERLEA T5 INSERT LE
C
B
A
ADJACENT SIDE WALL
F
E
F
CLEARANCE TO COMBUSTIBLES
PACIFIC ENERGY.
CONCERNANT LES CODES, RESTRICTIONS ET EXIGENCES D’INSPECTION D’INSTALLATION
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DE
• CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE,
DE VOTRE RÉGION.
MAÇONNERIE. NE RACCORDEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE
DESSERVANT UN AUTRE APPAREIL.
CONFORME À CAN/ULC-S635 OU CAN/ULC-S640.
DE L’APPAREIL. DANGER : RISQUE D’ÉLECTROCUTION.
SURÉLEVÉ - MONTEZ LES BÛCHES DE BOIS DIRECTEMENT SUR L’ÂTRE. REMPLACEZ LA
VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE.
• INSTALLEZ ET UTILISEZ SEULEMENT DANS UN FOYER PRÉFABRIQUÉ OU EN
• COMPOSANTS REQUIS POUR L’INSTALLATION : GAINE DE CHEMINÉE COMPLÈTE
DES DÉPÔTS DE CRÉOSOTE PEUVENT SE FORMER RAPIDEMENT.
• ALIMENTATION ÉLECTRIQUE : 115 V, 60 HZ, 1.2 AMP. ÉLOIGNEZ LE CORDON ÉLECTRIQUE
• POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. AUCUN PORTE-BÛCHES NI FEU
• INSPECTEZ ET NETTOYEZ LA CHEMINÉE RÉGULIÈREMENT - EN CERTAINES CONDITIONS,
• UTILISEZ CET APPAREIL SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE.
DATE OF MANUFACTURE
OUVREZ-LA SEULEMENT POUR ALIMENTER LE FEU. CE POÊLE EST CONÇU UNIQUEMENT
POUR BRÛLER DU BOIS DE CORDE. BRÛLER D’AUTRES MATÉRIAUX PEUT ENDOMMAGER
LE POÊLE OU LE BÂTIMENT.
L’APPAREIL.
• COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT TOUT TRAVAIL D’ENTRETIEN SUR
MADE IN CANADA
MANUFACTURED BY:
.
Efficiency and BTU Output
EPA Certied Emissions 1.8 grams per hour
LHV Tested Efciency 1 77%
HHV Tested Efciency 2 71%
EPA BTU Output 3 12,518 to 38,177 btu/hr
Maximum Wood Length 18 inches
Ideal Wood Length 16 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as tested using CSA B415 Performance testing of solid-fuel­burning heating appliances. LHV assumes the moisture is already in a vapour state so there is no loss of energy
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
2 Weighted Average Higher Heating Value (HHV) efciency as tested using CSA B415 Performance testing of solid-fuel­burning heating appliances. HHV includes the energy required to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA B415 Performance testing of solid-fuel-burning heating appliances and burn rates from the low and high EPA tests using Douglas Fir dimensional lumber.
OPERATING INSTRUCTIONS.
INSTALLATION INSPECTION IN YOUR AREA.
ULC-S635 OR CAN/ULC-S640. IN U.S.A. FLUE LINER CONFORMING TO UL-1777 OR DIRECT
FLUE CONNECTION ASSEMBLY.
WOOD FIRE DIRECTLY ON HEARTH.
ONLY WITH CERAMIC GLASS.
CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
CAUSE DAMAGE TO STOVE OR HOME.
MINIMUM CLEARANCE TO COMBUSTIBLES (MEASURED FROM FAN COVERS)
DÉGAGEMENT MINIMUM AUX COMBUSTIBLES (MESURÉ À PARTIR DE COUVERTURES DE VENTILATEUR)
A) ADJACENT SIDEWALL / PAROI LATÉRALE ADJACENTE 255 MM / 10 IN
B) MANTEL / MANTEAU 305 MM / 12IN
C) TOP FACING / REVÊTEMENT SUPÉRIEUR 305 MM / 12IN
D) SIDE FACING / REVÊTEMENT LATÉRAL 155 MM / 6 IN
E) FIRING SIDE / EPREUVE DU FEU, CANADA 457 MM / 18 IN
FIRING SIDE, U.S.A. 406 MM / 16 IN
F) OTHER SIDES / AUTRES CÔTÉS. 200 MM / 8 IN INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH UNDER THE UNIT, EXTENDING A DISTANCE OF 16IN /
406MM IN FRONT OF THE FIREPLACE OPENING FACE. // INSTALLER UNIQUEMENT SUR UN COEUR NON
COMBUSTIBLE SOUS L’APPAREIL, S’ÉTENDANT À UNE DISTANCE DE 16po / 406mm DEVANT LE FACE
LISTED SOLID WOOD FUEL FIREPLACE INSERT / APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMINÉE
CERTIFIED FOR USE IN CANADA AND U.S.A.
CERTIFIED TO / CERTIFIÉ POUR:ULCS628-93/ UL1482 (2011)
Refer to Intertek’s Directory of Building Products for detailed information
MODEL / MODÈLE:
D’OUVERTURE DU FOYER.
• INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND
• INSTALL AND USE ONLY IN MASONRY OR FACTORY BUILT FIREPLACE.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• COMPONENTS REQUIRED FOR INSTALLATION : FULL FLUE LINER CONFORMING TO CAN/
• ELECTRICAL RATING 115V, 60HZ, 1.2 AMP. ROUTE POWER CORD AWAY FROM UNIT.
• DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
• FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE - BUILD
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY. REPLACE GLASS
• INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE,
INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certied to comply with 2020 crib wood particulate
• STOVE IS DESIGNED TO BURN CORDWOOD ONLY. BURNING OTHER MATERIALS MAY
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
• CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.
emission standards, using test Method 28R
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER
Figure 1: 100002100 - SUPER _ ALT5 Insert LE rating Label
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With practice, you will become procient in operating your heater and will obtain the performance for which it was designed.
NATIONAL FIREPLACE INSTITUTE
CERTIFIED
www.nficertified.org
We recommend that our products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute (NFI) or in Canada by Wood Energy Technical Training (WETT)
3ALT5 LE Insert 230819-32
Wood Energy Technical Training
www.wettinc.ca
100003038
Safety
CAUTION: Never use gasoline type lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or "freshen up" a fire in this heater. Keep all such liquids well away from the heater while it is in use.
Instruct all members of your family on the safe operation of the heater. Ensure they have enough knowledge of the entire system if they are expected to operate it. Stress the section on chimney fires and the importance of following the steps outlined "In Case of Chimney Fire".
Chimney Smoke and Creosote Formation
When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney ue of a slow burning re. As a result, creosote residue accumulates on the ue lining. When ignited, this creosote makes an extremely hot re. The chimney connector and chimney should be inspected periodically (at least once every two months) during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated (3 mm. or more), it should be removed to reduce the risk of a chimney re.
1. Highest smoke densities and emissions occur when a large amount of wood is added to a bed of hot coals and the air inlet is closed. The heated wood generates smoke, but without ample air, the smoke cannot burn. Smoke-free, clean burning requires small fuel loads, two or three logs at a time or 1/4 to 1/2 of fuel load and leaving the air inlet relatively wide open, especially during the rst 10 to 30 minutes after each loading, when most of the smoke generating reactions are occurring. After 30 minutes or so, the air inlet can be turned down substantially without excessive smoke generation. Wood coals create very little creosote-producing smoke.
2. The cooler the surface over which the wood smoke is passing, the more creosote will be condensed. Wet or green wood contributes signicantly to creosote formation as the excess moisture that is boiled off cools the re, making it difcult for the tars and gases to ignite, thus creating dense smoke and poor combustion. This moisture-laden smoke cools the chimney, compounding the problem by offering the smoke the ideal place to condense.
In summary, a certain amount of creosote is inevitable. Regular inspection and cleaning is the solution. The use of dry, seasoned wood and ample combustion air will help to minimize annoying smoke emissions and creosote buildup.
Chimney Fires
The dangerous side effect of excessive creosote buildup is a chimney re. This causes much higher than normal temperatures in the chimney and on its exterior surfaces. Temperatures inside the chimney can exceed 2000°F (1100°C). Ignition of nearby or touching combustible material is more likely during a chimney re. Proper clearances are critical to prevent damage during such a re.
Chimney res are easy to detect; they usually involve one or more of the following:
• Flames and sparks shooting out of the top of the chimney
• A roaring sound
• Vibration of the chimney
100003038
4
ALT5 LE Insert 230819-32
To Avoid a Chimney Fire
1. Burn wood cleanly. Do not burn wet wood or turn down the unit too quickly after loading.
2. Do not let creosote build up to a point where a chimney re is possible.
3. Do not have res in the heater that may ignite chimney res. These are excessively hot res, such as when burning household trash, cardboard, Christmas tree limbs, or even ordinary fuel wood; (eg. with a full load on a hot bed of coals and with the air inlet wide open for more time than is needed to completely char a fresh fuel load.)
4. The Chimney and connector pipe should be inspected /cleaned periodically.
In Case of a Chimney Fire
1. Prepare to evacuate to ensure everyone's safety. Have a well understood plan of action for evacuation. Have a place outside where everyone is to meet.
2. Close air inlet on stove.
3. Call local re department. Have a re extinguisher handy. Contact your local municipal or provincial re authority for further information on how to handle a chimney re. It is most important that you have a clearly understood plan on how to handle a chimney re.
4. After the chimney re is out, the chimney must be cleaned and checked for stress and cracks before starting another re. Also check combustibles around the chimney and the roof.
• We recommend the services of professionals who are certied by a “Qualied agency”; such as
NFI (National Fireplace Institute®) in the United States, CSIA (Chimney Safety Institute of America) in the United States and Canada, WETT (Wood Energy Technology Transfer) in Canada or APC (Association des Professionnels du Chauffage) in Quebec
Curing of the Paint Finish
To achieve the best nish, the paint on your stove must be baked on. When burning your stove for the rst 2-3 times it is very important that the room be well ventilated. Open all windows and doors. Smoke and fumes caused by the curing process may cause discomfort to some individuals.
Disposal of Ashes
Ashes should be placed in a metal container with a tight tting lid. The closed container of ashes should be placed on a non-combustible oor or on the ground, well away from all combustible materials, pending nal disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in closed container until all cinders have thoroughly cooled. Other waste should not be placed in this container.
5ALT5 LE Insert 230819-32
100003038
Operation
CAUTION: Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.
WARNING: Always keep loading door closed when burning. This heater is not designed for open door burning.
WARNING: No alteration or modification of the combustion air control assembly is permitted. Any tampering will void warranty and could be very hazardous.
WARNING: Do not use grates or andirons to elevate the fuel. Burn directly on the fire bricks. Replace broken or missing bricks. Failure to do so may create a hazardous condition.
Wood Selection
This heater is designed to burn natural wood only. Higher efciency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.
Wood should be properly air dried (seasoned) for six months or more. Wet or undried wood will cause the fire to smoulder and produce large amounts of smoke and creosote. Wet wood also produces very little heat and tends to go out often. Wood should be stored under cover away from open flame or heat sources.
DO NOT BURN :
• Salt water wood * • Treated wood
• Wet or green wood • Coal/charcoal
• Garbage * • Solvents
• Lawn clippings/yard waste Unseasoned wood
• Railroad ties • Manure or animal remains
• Materials containing rubber, including tires • Materials containing plastic
• Construction or demolition debris • Materials containing asbestos
• Waste petroleum products, paints, paint thinners, or asphalt products
* These materials contain chlorides which will rapidly destroy metal surfaces and void warranty.
Burning these materials may result in the release of toxic fumes or render the heater ineffective and cause smoke.
Do not burn anything but wood. Other fuels, eg. charcoal, can produce large amounts of carbon monoxide, a tasteless, odourless gas that can kill. Under no circumstances should you attempt to barbecue in this heater.
The prohibition against burning these materials does not prohibit the use of re starters made from paper, cardboard, saw dust, wax and similar substances for the purpose of starting a re in an affected wood heater.
• Paper products, cardboard, plywood, or particleboard.
How to Test Your Wood
Add a large piece of wood to the stove when it has a good large bed of coals. It is dry if it is burning on more than one side within one minute. It is damp if it turns black and lights within three minutes. If it sizzles, hisses and blackens without igniting in ve minutes it is soaked and should not be burnt.
100003038
6
ALT5 LE Insert 230819-32
Lighting a fire
WARNING: Never use chemicals or any other volatile liquid to start a fire. Do not burn garbage, or flammable fluids such as gasoline, naptha, or engine oil.
1. Adjust air control to “High” position(all the way to the left) and open door.
2. Place crumpled newspaper in the centre of the heater and crisscross with several pieces of dry kindling. Add a few small pieces of dry wood on top.
3. Ignite the paper and leave the door ajar approximately 1/2"(13mm) - 1"(25mm) until the wood kindling is fully engulfed in ame.
4. After the kindling is fully engulfed add a few small logs. Close door.
5. Begin normal operation after a good coal base exists and wood has charred.
Normal Operation
WARNING: This Insert has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with the operating instructions in this manual.
1. Set air control to a desired setting. If smoke pours down across the glass (waterfall effect) this indicates you have shut the control down too soon or you are using too low a setting. The wide range control panel makes nding the desired setting for your application easy. As every home's heating needs vary (ie. insulation, windows, climate, etc.) the proper setting can only be found by trial and error and should be noted for future burns.
2. To refuel, adjust air control to high, and give the re time to brighten. Open the door slowly, this will prevent back pufng.
3. Use wood of different shape, diameter and length (up to 18"(457mm)). Load your wood endwise and try to place the logs so that the air can ow between them. Always use dry wood.
4. Do not load fuel to a height or in such a manner that would be hazardous when opening the door.
5. For extended or overnight burns, unsplit logs are preferred. Remember to char the wood completely on maximum setting before adjusting air control for overnight burn.
• Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet or unseasoned wood, do so only with the air inlet set open enough to maintain a good strong re and fairly high chimney temperatures. Do not attempt to burn overnight using green wood or wet wood. Wet wood can cause up to 25% drop in heater output, as well as contributing signicantly to creosote buildup.
DO NOT OVERFIRE THIS HEATER:
Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater and chimney. A glowing red, top or vent pipe are indications of
overring. Failure to rectify an over ring condition can be hazardous and may void the manufacturer's warranty.
7ALT5 LE Insert 230819-32
100003038
Convection Blower Operation
The Insert comes equipped with twin variable speed circulating air blowers. The blower system is thermostatically controlled for automatic operation, as well as manually with a convenient bypass switch. Automatic Blower Operation: Allows the blowers to turn on automatically once the Insert has come up to operating temperature. It will also shut the blowers off after the re has gone out and the appliance has cooled to below a useful heat output range. Push the rocker switch to the “OFF” position and set the fan speed control to a desired setting.
Manual Blower Operation: Push the rocker switch to the “ON” position and set the fan speed control to a desired setting. This will bypass the temperature switch and allow full control of the blowers.
Suggested settings:
- Combustion air control setting of “L” (low) position (pushed to the far right), operate blower speed control
on “Low”.
- Combustion air control set at anything above “L” (low), operate blower speed control at desired setting.
Restarting After Extended or Overnight Burns
1. Open door and rake hot embers towards the front of the heater. Add a couple of dry, split logs on top of embers, close door.
2. Adjust air control to high and in just a few minutes, logs should begin burning.
3. After wood has charred, reset air control to desired setting.
4. To achieve maximum ring rate, set control to high "H". Do not use this setting other than for starting or preheating fresh fuel loads.
Proper Draft
1. Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors.
2. Too much draft may cause excessive temperatures in the appliance. An uncontrollable burn or a glowing red stove part or chimney indicates excessive draft.
3. Inadequate draft may cause back pufng into the room and plugging of the chimney. Smoke leaking into the room through appliance and chimney connector joints indicates inadequate draft.
Remember the correct air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions.
Ash Removal
Caution: Ashes are to be removed only when the heater is cold. Whenever ashes get 3"(76mm) to 4"(102mm)
deep in your rebox, and when re has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1" (25 mm) deep on the rebox bottom to help maintain a hot charcoal bed.
See section “Disposal of Ashes” on page 5.
100003038
8
ALT5 LE Insert 230819-32
Maintenance
WARNING: ONLY USE MATERIALS SUPPLIED BY MANUFACTURER WHEN DOING MAINTENANCE OR REPLACEMENTS.
1. If glass becomes darkened through slow burning or poor wood, it can readily be cleaned with replace glass cleaner when stove is cold. Never scrape with an object that might scratch the glass. The type and amount of deposit on the glass is a good indication of the ue pipe and chimney buildup. A light brown dusty deposit that is easily wiped off usually indicates good combustion and dry, well-seasoned wood and therefore relatively clean pipes and chimney. On the other hand, a black greasy deposit that is difcult to remove is a result of wet and green wood and too slow a burning rate. This heavy deposit is building up at least as quickly in the chimney.
DOOR GASKETS -
The gasket used by Pacic Energy (5/16” medium density berglass rope) requires only light pressure to seal. This will prolong seal life. It is important that the door seal be maintained in good condition. Periodically inspect seals and replace if necessary. Follow the instructions included in the kit, available from your nearest Pacic Energy dealer.
DOOR GLASS -
Do not slam loading door or otherwise impact glass. When closing door, make sure that no logs pro­trude to impact the glass. If the glass gets cracked or broken, it must be replaced before using the stove. Replacement glass can be obtained from your dealer. Use 17-1/4”(438mm) x 11-3/8”(289mm) x 5 mm. Ceramic glass only. Do not substitute with any other type.
To remove broken glass, undo the four retaining screws and remove clamps and frame, noting position for re-assembly. Remove all particles of glass . Be careful as they are very sharp. Install new glass complete with gasket. Replace frame, clamps and screws.
CAUTION:
- do not overtighten, tighten screws very carefully
- do not clean glass when hot
- do not use abrasive cleaners on glass
2. The area where boost combustion air enters the rebox must be kept clear of excessive ash buildup which will block air ow. This area is at the front of the rebox.
3. Do not store wood within heater installation clearances, or within the space required for fuel loading and ash removal. Keep the area around the heater clean and free of loose combustibles, furniture, newspapers, etc.
4. If the plated door requires cleaning, use mild soap and water only. Use of abrasive cleaners will void warranty.
5. Establish a routine for the fuel, wood burning and ring technique. Check daily for creosote buildup until experience shows how often you need to clean to be safe.
6. Be aware that the hotter the re, the less creosote is deposited. Weekly cleaning may be necessary in mild weather, even though monthly cleaning is usually enough in the coldest months when burning rates are higher. When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote.
9ALT5 LE Insert 230819-32
100003038
Maintenance Checks
Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (See website for descriptions and more detail)
Weekly:
• Firebrick - Visual, for cracking.
• Door Gasket - sagging, placement, damage.
Monthly
• Bafe.
• Brick rail tabs and brick rails.
• Air riser tube in the back of the rebox.
• Back side of airwash chamber.
• Bafe locking pin.
• Boost tube cover.
• It is recommended to inspect the liner and connector monthly and to have the liner cleaned annually or more frequently if required.
When Cleaning the Chimney System:
• Top bafe board/blanket.
• Top heat shield and mounting bolt.
• Bafe Gasket.
• Brick Rails.
• Manifold.
Blower:
The blowers should be cleaned out a minimum every six months by using a vacuum on the blower intakes to remove any dust and debris. See “Fan Speed Controller Relocation” section on page 12, steps 1 & 2, for how to remove the panels and access the blowers.
Baffle:
• Some warping of the bafe is normal (up to 1/4” or 6.5mm). Replace if the bafe has permanent warping greater than this or has cracking or breakage.
• Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and may void your warranty.
Baffle Removal
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR INSULATION REMOVED.
Removal
Remove retaining pin at the back top of the rebox, just under the bafe. Lift bafe up and pull forward to disconnect from the supply tube. Tilt bafe sideways to drop down and remove from rebox. Inspect gasket between bafe and supply tube. If necessary, replace with gasket part number 80000365, available from your Pacic Energy dealer. Re-install bafe assembly in reverse order. The two side pieces of insulation must be tight against the side rails.