Pach and Company QC Series Quick Guide

Exit program, cancel call 23 Lock-out Count
5
ess
o
ease
doo
Save program 24 Alarm
00 Change master code (0000 is
default)
01 Add new forwarding tenant’s
directory
02 Edit existing tenant’s directory 27 Talk time (060-240
03 Delete existing tenant’s
directory
04 Clear all forwarding tenant’s
directory
05 Enable/Disable Call 33 Temporary code 06 New access code 34 Special code 07 Delete access code 35 Temporary card 08 Clear all access code 36 Special card 09 Access code digit (4-8 digit).
Default is 4-digit
10 Add new card 39 Remote access
11 Delete card 40 DTMF relay 1 (0-9). 12 Clear all card 41 DTMF relay 2 (0-9). 13 Set time 42 Relay 2 Mode
14 Set date 43 DND: do not disturb time 15 Initializing event recording 44 Disable Time zone relay 16 AUS= auto unlock schedule
(0-9 schedule)
17 TMZ= time zone. 20 TMZ, 00-
20.
18 HLD= holiday zone. 20 HLD,
1-20
19 Directory digit (2-4 digit).
Default is 2-digit
20 AUXIN1
0= disable (default) 1= enable control by relay 1 open interval 2= relay 1 control by AUXIN1
21 AUXIN2
0= disable (default) 1= enable control by relay 2 open interval 2= relay 2 control by AUXIN2
22 Do not disturb
0= disable (default), 1= enable
0= disable 1= local beep for 60 seconds 2= disable system for 60 seconds with no beep 3= call directory (0-9)
25 Keypad beep
0= disable (default) 1=enable
26 Door beep
0= disable 1= enable (default)
second). Default=60 second
28 Unlock relay1 time
(12-99 second). Default= 12 second
29 Unlock relay2 time
(12-99 second). Default= 12 second
38 System acknowledge
(0-9). Default= 3 0= disable
1=enable (default) Default=9 Default=8 1= door control (default)
2= relay 2 trigger simultaneously as relay 1 3= enable if function code 24 is enable 4= turn relay 2 on and off On=7, Off=6
zone (0-9) 1, 2 or both
45 Relay 1 and 2 unlock
timer
46 Firmware version 48 PBX enable. Default=
disable
49 Edit Access code 50 Erase the memory to
factory default
51 Welcome screen
OPERATION
Two ways call from the system
1. Press to scroll name from A-Z or to scroll name from Z-A then press to call name selected.
2. Press wait for dial tone then press the directory number
Defective system under manufacturer warranty,
call 1-888-678-7224 for advance replacement
24 Months warranty6 Months warranty
Manuals are available online at www.pach-co.com
for complete system
for Printed Circuit Board
Log on to programming: Press and simultaneously then release,
the welcome message will stop scrolling (repeat if screen still scrolls) enter 4-digit “MASTER CODE” (0000 is default), the screen will show:
Select the “Function Code” from the table
OPERATION
Opening the door remotely Opening the door with the access code
screen will stop scrolling) then press a valid 4-digit access code.
Extending talk time
the time out warning beep.
Calling into the system
1. Enable function code 39 and function code 38 must be set 1-9
2. Call the system phone number, hear one beep if the system answering the call.
3. Press then 4-digit master code, hear one short beep
4. Press to establish two way communication
.Pr
tenant must press from the phone after
r to rel
press (relay 1) or (relay 2)
press (display
:
the
r.
QC1IP and QC2IP DEFAULT IP IP: 192.168.1.230 SUBNET: 255.255.255.0 GATEWAY: 192.168.1.1 DNS: 192.168.1.1 USERNAME: Administrator PASSWORD: 8888
WARNING: DO NOT USE ON BOARD
12VDC and GND TO POWER A DOOR STRIKE OR MAGNETIC LOCK
SEPARATE POWER MUST BE USED TO POWER A DOOR STRIKE OR MAGNETIC LOCK.
QUANTUM QC1IP
QUANTUM QC SERIES
Monday-Friday 7:00 am-4:00 pm PST at 1-888-678-7224
Technical Info is available online www.pach-co.com
Technical Support is available