Pach and Company AeGIS SK9 User Manual

SPECIFICATIONS Power Input: 12 VAC/DC 40VA UL Listed Transformer (12 VAC
is supplied by Pach & Company) or 12 VDC Power Supply (not supplied, power supply output voltage must be 13.5-14.5 VDC).
Current Consumption:350 mA Idle, 475 mA operation. Emergency Battery: 12 VDC, 4 Ahr rechargeable with 12 VDC
Night Light: 14 VAC 200 mA Incandescent Lamp. Operating Environment: Temp. 0˚ - 140˚ F Relative Humidity: 0% to 95%. Relay Output: From C Dry Contact 120 Vac 10A/ 24 VDC 10 A/
250 Vac 7A.
Mounting: Surface (accessories APM1, APM2 and APM5 Construction: 16 Gauge Cold Rolled Steel with Brushed
Stainless Steel Faceplate.
Dimension: 6 3/4” (H) x 5 3/4 “ (W), Depth 3 1/2” to 2 1/2” . Shipping Weight: 4 Lbs.
OPERATIONS System’s ID Number and Jumper Setting
JP2=ON ROTARY SWITCH SETTING
HEX DECIMAL HEX DECIMAL
0 0 8 8 1 1 9 9 2 2 A 10 3 3 B 11 4 4 C 12 5 5 D 13 6 6 E 14 7 7 F 15
JP2=OFF ROTARY SWITCH SETTING
HEX DECIMAL HEX DECIMAL
0 16 8 24 1 17 9 25 2 19 A 26 3 20 B 27 4 21 C 28 5 22 D 29 6 23 E 30 7 24 F 31
Relay Output Duration Time (door open interval) always set for 5 seconds. Install an isolation relay with built-in timer or door strike with built-in timer if you need shorter or longer output duration time.
To Access Door or Gate using the 4-digit access code
by Pach & Co. Installation Manual
Parts below are included with the SK9 Missing Parts, contact Pach and Company 1-888-678-7224 Defective system under manufacturer warranty,
call 1-888-678-7224 for advance replacement
24 Months warranty for complete system, installation labor does
not include on the warranty.
6 Months warranty
Installation labor does not include on the warranty
CD contains manual, catalog and cutsheet or download at
www.pach-co.com
for Printed Circuit Board (SK9PCB).
then 4-digit access code
ONE LONG TONE access is granted. TWO LONG Tone access is denied
3
1
5
2
1. RS-485 Polarity sensitive. Use 18-2 shielded stranded wires or Category 5 twisted.
2. Earth Ground use 16 gauge solid wire
3. Power 12 Vac 40VA supplied Use 12 Vdc power supply if battery back up is used.
4. Optional 26-Bit Wiegand Reader can be installed for double security. Combination of card reader and 4-digit access code. Enable function 24 on the 9000 or NPB 9000 for this feature.
TO GAIN ACCESS, PRESENT THE CARD OR KEYFOB THEN PRESS
then 4-digit access code.
5. JP3= OFF and JP4=ON must be set as shown on diagram above.
Connection for multi systems is same as single system
Loading...