Pach and Company AeGIS SCR9 User Manual

SPECIFICATIONS Power Input: 12 VAC/DC 40VA UL Listed Transformer (12 VAC
is supplied by Pach & Company) or 12 VDC Power Supply (not supplied, power supply output voltage must be 13.5-14.5 VDC).
Current Consumption:350 mA Idle, 475 mA operation. Emergency Battery: 12 VDC, 4 Ahr rechargeable with 12 VDC
Night Light: 14 VAC 200 mA Incandescent Lamp. Operating Environment: Temp. 0˚ - 140˚ F Relative Humidity: 0% to 95%. Relay Output: From C Dry Contact 120 Vac 10A/ 24 VDC 10 A/
250 Vac 7A.
Mounting: Surface (accessories APM1, APM2 and APM5 Construction: 16 Gauge Cold Rolled Steel with Brushed
Stainless Steel Faceplate.
Dimension: 6 3/4” (H) x 5 3/4 “ (W), Depth 3 1/2” to 2 1/2” . Shipping Weight: 4 Lbs.
OPERATIONS System’s ID Number and Jumper Setting
JP2=ON ROTARY SWITCH SETTING
HEX DECIMAL HEX DECIMAL
0 0 8 8 1 1 9 9 2 2 A 10 3 3 B 11 4 4 C 12 5 5 D 13 6 6 E 14 7 7 F 15
JP2=OFF ROTARY SWITCH SETTING
HEX DECIMAL HEX DECIMAL
0 16 8 24 1 17 9 25 2 19 A 26 3 20 B 27 4 21 C 28 5 22 D 29 6 23 E 30 7 24 F 31
Relay Output Duration Time (door open interval) always set for 5 seconds. Install an isolation relay with built-in timer or door strike with built-in timer if you need less or more output duration time.
To Access Door or Gate using the Wiegand Proximity Card Reader. The red LED on the card reader must be ON if the power is ON. Place the card or keyfob about an inch from the RED LED. The LED will change status to flickering green and the SCR9 will make one beep then ONE LONG TONE access is granted. TWO LONG Tone access is denied
by Pach & Co. Installation Manual
Parts below are included with the SCR9 Missing Parts, contact Pach and Company 1-888-678-7224 Defective system under manufacturer warranty,
call 1-888-678-7224 for advance replacement
24 Months warranty for complete system, installation labor does
not include on the warranty.
6 Months warranty
Installation labor does not include on the warranty
CD contains manual, catalog and cutsheet or download at
www.pach-co.com
for Printed Circuit Board (SCR9PCB).
3
1
5
2
1. RS-485 Polarity sensitive. Use 18-2 shielded stranded wires or Category 5 twisted.
2. Earth Ground use 16 gauge solid wire
3. Power 12 Vac 40VA supplied Use 12 Vdc power supply if battery back up is used.
4. 26 Wiegand prewired from manufacturer
5. JP3= ON and JP4=OFF must be set as shown on diagram above.
Connection for multi systems is same as single system