The Oxmoor RCS™ Room Com-
AMPLIFIER
AMPLIFIER
AMPLIFIER
AMPLIFIER
ZONE A
ZONE B
ZONE C
ZONE D
ZONE A
ZONE B
ZONE C
ZONE D
VOLUME CONTROL
MIXER
MIXER
MIXER
MIXER
Volume Control Mixer Mute SwitchCombine Switch
Remote Volume Control
LOGIC CONTROLLER
CONTROL PANEL
ZONE A ZONE B
ZONE C
ZONE D
RCS-4 CPS
MIXING MATRIX
VOLUME CONTROL
A+B
B+C
D+A
C+D
C
B
SOURCE
SOURCE
SOURCE
A
D
SOURCE
bining System consists of:
• RCM-4™ Logic Module
• RMX-44™ Mixing Matrix
• DCA-2™ Digital Control
Attenuator
• RC-16™ Remote Controls
Using these components, Oxmoor
offers two-room, three-room, and
four-room combining systems
with volume control.
As a matrixing and level control
ensemble, the combining system
is positioned between the linelevel outputs of the individual
zone mixers and the inputs of their
power amplifier.
RCS ROOM COMBINING SYSTEM
At the heart of the system is the
RCM-4 Room Combining Module. The RCM-4 sends out several
types of control messages: it delivers both zone-combining and
source-selection commands to an
RMX-44 Mixing Matrix. The block
drawing illustrates an optional
Control Panel which serves as the
module's user interface.
When combining zones, the RMX44 mixes all signal sources (mixer
outputs) within the combined
zones. Also, all RC-16 Remote
Controls within the combined
zones will be linked together and
forced to a common preset level.
This allows all RC-16s in each combined zone to serve as master level
controls over all speakers in the
combined system.
The combining system may be
user programmed for two different modes of operation when
Oxmoor Corporation, LLC, 309 Cahaba Valley Parkway, Birmingham, AL 35124 USA Toll Free: 1-800-262-6898
Phone: 205-982-8200 Fax: 205-982-8250 E-mail: info@oxmoor.com Internet: www.oxmoor.com
zones are combined. One configuration allows the RMX-44 to mix
all sources within the combined
zones. Because all sources within
the combined zones are active,
microphones, etc. may be plugged
in wherever desired within the
combined zones.
The second configuration mutes
the sources (using the Mixer Mute
Switch) of the combined zones,
allowing the user to select a source
(mixer) or a combination of sources
RCS-4CPS Room Combining System
to be used within combined
zones. The user can select where
the head table will be – where
the entertainment microphones
will plug in – without any chance
of hum, buzz, or ambient noise
from unused sources.
For more information on any
Oxmoor product, please contact the
Oxmoor Sales Department. Or
download complete product brochures and manuals at our website:
www.oxmoor.com.

RCS FEATURES & SPECIFICATIONS
• Compatible with most existing mixers and amplifiers.
• Up to 4 independent "local" sound systems, such as
adjacent banquet or meeting rooms, may be treated
as "zones" and instantly combined to create one larger
system.
• A mix of 2, 3, or 4 zones may be combined without
sacrificing the autonomy of those excluded.
• The RCS may be programmed to mix all sources
(mixer outputs) within the combined zones, allowing
source microphones, etc., to be plugged in anywhere
desired.
• The RCS may be programmed to mute all sources
(mixer outputs) within combined zones, allowing user
to selectively activate sources within the combined
zones.
• The RCS offers a Wake-Up level control. On power
up all remote volume controls are reset to a predetermined level.
• Remote audio level control is available for each independent zone using RC-16s.
• Each RC-16 Remote Control has a unique LED array
which provides a Virtual Pointer to show system level
in 3 dB steps.
• The standard system configuration allows all RC-16
Remote Controls to be linked together within combined zones. All RC-16s are in sync and will track
“up” or “down” adjustments made at any of the RC16s within the combined system.
SYSTEM CONFIGURATION
The RCS is available as a two-room, three-room, or
four-room combining system.
SYSTEM COMPONENTS
• Oxmoor's Master Control Panel (Optional)
• RCM-4 Room Combining Module
•RMX-44 Mixing Matrix Module
• DCA-2 Digital Control Attenuator
• RC-16 Room Volume Controls
•Wall Mounting Plates For RC-16s
• System Wiring Harness
CONTROL PANEL OPTIONS
Below are Oxmoor's Master Control Panel options for
the RCS. The system may be purchased without panels to permit contractor fabrication of custom panels.
®
RCS CONTROL PANEL
ZONE A
A
SOURCE
ZONE B
B
SOURCE
A+B
RCS-2CP
®
RCS CONTROL PANEL
ZONE A ZONE B
AB
SOURCE
SOURCE
A+B
ZONE C
C
SOURCE
B+C
FREQUENCY RESPONSEFREQUENCY RESPONSE
FREQUENCY RESPONSE
FREQUENCY RESPONSEFREQUENCY RESPONSE
HUM AND NOISEHUM AND NOISE
HUM AND NOISE
HUM AND NOISEHUM AND NOISE
DISTORTION (THD OR IMD)DISTORTION (THD OR IMD)
DISTORTION (THD OR IMD)
DISTORTION (THD OR IMD)DISTORTION (THD OR IMD)
AUDIO INPUTSAUDIO INPUTS
AUDIO INPUTS
AUDIO INPUTSAUDIO INPUTS
AUDIO OUTPUTSAUDIO OUTPUTS
AUDIO OUTPUTS
AUDIO OUTPUTSAUDIO OUTPUTS
MAX INPUT/OUTPUT LEVELMAX INPUT/OUTPUT LEVEL
MAX INPUT/OUTPUT LEVEL
MAX INPUT/OUTPUT LEVELMAX INPUT/OUTPUT LEVEL
VOLUME CONTROL RANGEVOLUME CONTROL RANGE
VOLUME CONTROL RANGE
VOLUME CONTROL RANGEVOLUME CONTROL RANGE
TRIM POT GAIN RANGETRIM POT GAIN RANGE
TRIM POT GAIN RANGE
TRIM POT GAIN RANGETRIM POT GAIN RANGE
MECHANICALMECHANICAL
MECHANICAL
MECHANICALMECHANICAL
Specifications subject to change without notice.
Oxmoor Corporation, LLC, 309 Cahaba Valley Parkway, Birmingham, AL 35124 USA Toll Free: 1-800-262-6898
Rev. 7.01
................
........ 4 Hz to 60 kHz +0, -3 dB
................
(Ref. +4 dBm Output at Unity Gain)
......................................
................... -80 dB (Ref. 0 dBm Output at Unity Gain)
......................................
......
... -80 dB (Ref. +4 dBm, 20 Hz to 20 kHz)
......
..............................................
....................... Four Channel, XLR 3-pin Connectors,
..............................................
......................................
................... Four Channel, XLR 3-pin Connectors,
......................................
..................................................
......................... DCA-2 Digital Control Attenuator,
..................................................
Input Impedance 80 k Ohms
Output Impedance 75 Ohms
....
.. +20 dBu
....
........
.... 0 to -43.5 dB in 29 Steps, Plus a
........
90 dB Full Attenuation "Kill" Step
..................
.........
±15 dB (Ref. 0 dBu Output)
..................
RMX-44 Mixing Matrix, and RCM-4
Room Combining Module are 1U RackMount Devices. The Oxmoor Master
Control Panel is a 4U Rack-Mount
Panel.
®
RCS CONTROL PANEL
ZONE A ZONE B
AB
SOURCE
A+B
®
RCS CONTROL PANEL
A
SOURCE
ZONE A ZONE B
DC
SOURCE
ZONE D
RCS-3CP
ZONE C
SOURCE SOURCE
SOURCE
B+C
C+D
RCS-4CPR
B
SOURCE
SOURCE
ZONE C
D+A
A+B
B+C
C+D
RCS-4CPS
Phone: 205-982-8200 Fax: 205-982-8250 E-mail: info@oxmoor.com Internet: www.oxmoor.com
ZONE D
DC