Oxford PRECISION BS-60E, BS-120E Instruction Manual

Electronic Bench Scales
OXFORD
PRECISION
OXD-844-5010K/OXD-844-5030K
INSTRUCTION MANUAL
• Battery or mains powered (batteries provided)
• Wall or desk mounted display
• Dual reading – metric or imperial
• Capacities: Model: BS-60E 60kg/132.28lb Model: BS-120E 120kg/264.56lb
• RS232 Interface
Diagrammatic information
Adjustable feet
Load cell
Overload protection screws
Battery compartment/ cover
4 x AA
batteries
Fig 1. Underside view of the scales
Fig 2. Display unit mounting options and views
OXFORD PRECISION Victoria Works, Leicester, England
© The Kennedy Group Ltd. 08/04
OXD-844-5010-5030K_Instructions.qxd 05/08/2008 14:19 Page 1
Battery and AC Adaptor
1. Specifications
2. How To Programme The Auto-Off Time
3. Weighing Operation
Please read this manual before use.
Oxford Electronic Bench Scales are designed to run on AC power (AC adaptor included) or 4 x AA batteries (supplied). The batteries should be installed in the battery compartment, which is located on the underside of the base unit.
The AC adaptor allows the scales to be operated via 240V mains electricity supply, and connects to the scales via the adaptor housing to the rear of the electronic display unit.
To install batteries, remove the battery cover on the underside of the base unit and insert the 4 x AA batteries, making sure that you have the correct polarity, as indicated on the base unit battery housing. Reposition the battery housing cover and reinsert the screws to secure.
Note: Only use the scales on a flat and stable surface. Make sure that the chosen surface is sturdy enough to support the weight of the scales and the items to be weighed. The height of the base unit can be adjusted by turning the feet in an anti-clockwise direction to raise and a clockwise direction to lower the base unit.
Model Capacity Graduation
BS-60E 60kg/132.28lb 0.02kg/0.05lb
BS-120E 120kg/264.56lb 0.05kg/0.1lb
(a) With the power OFF, press and hold the PRINT key, and press the ON/OFF key until the
indicator displays “A.OFF.X” (X=0,1,2,3,4,5,6,7,8,9 minutes), the display value “X” is the auto-off time. When the display is “0” auto-off is disabled.
(b) To change the auto-off time, press the UNIT key which will increase the X value by 1.
Press the TARE key to confirm the auto-off time.
(c) To exit the auto-off time programme, press ON/OFF, which will reset the diplay.
The factory setting is X=0.
When the ON/OFF key is pressed the display will initially be shown as 60.00kg (OXD-844-6010K) or 120.00kg (OXD-844-5030K), when the scale resets itself to 0.00 the scale is ready for use and the following operations are enabled:
(a) To change the unit of measurement on the display, press the UNIT key. This toggles the
display between kg and lb.
(b) If an item is to be weighed in a container, the weight of the container can be subtracted
by placing it on the scales and resetting the zero point. The maximum weight at which the zero point can be reset is 25% of the total capacity. This operation is activated by pressing the ON/OFF key for 2 seconds. If the ON/OFF key is depressed for a greater length of time, the scales will be turned off.
4. Advanced Operating Instructions
Calibration
(c) Press the TARE key to tare or zero the scale after the scales have been used in the
manner described in Section 3(b).
(d) When the scales are connected to a computer via the RS232 interface, data can be
transferred through the RS232 port. To transmit data in this manner press the PRINT key. Data will be transmitted through the RS232 port.
Please note: The combined tare and net weight must not exceed the capacity of the scales.
Display messages are generated in certain circumstances and should be interpreted as follows: (i) 60.00/120.00 The scales capacity is 60kg or 120kg and has not yet set itself to
its stable zero point. (ii) 0 The zero setting is too high. (iii) A.OFF.X Indicates auto-off time. (iv) CAL-0 Calibration zero indicator. (v) CAL-F Calibration full capacity indicator. (vi) CAL..Er Calibration error. (vii) Ach.Er Analogue channel error. (viii) EEP.Er Read/Write error. (ix)
_______
The weight exceeds maximum capacity (60.18kg/120.45kg) (x) _______ The input signal is too small. (xi) Lo Low voltage.
Protocols
When scale’s “P” is pressed or the carriage return (0d hex) is received, PS-103 scale will transmit weight, unit, stability, over/down or low voltage message according to the following protocol:
Baud rate : 9600bps Start bit : 1 bit Data bits : 8 bits Stop bit : 1 bit Parity : none
The calibration of this product requires specialist tools and should only be carried out by persons with appropriate skills/qualifications. Should you experience any problems please return the goods to your supplier, who will arrange professional calibration of the scales.
UNDER NO CIRCUMSTANCES SHOULD MAINTENANCE OR CALIBRATION BE ATTEMPTED BY PERSONS WITHOUT APPROPRIATE SKILLS OR QUALIFICATIONS. SUCH ACTIONS MAY RESULT IN IRREPAIRABLE DAMAGE AND WILL ALSO INVALIDATE ANY GUARANTEE OR WARRANTY.