Oxford Journey Installation Manual

®
Oxford
Oxford® Journey
User Instruction Manual & Warranty
To avoid injury, read user manual prior to use.
Oxford® Journey
Manuel de l’utilisateur et garantie
Afin d’éviter tout accident, veuillez lire attentivement la notice avant utilisation.
Oxford® Journey
Manual de Instrucciones y Garantia para el Usuario
Oxford® Journey
Benutzerhandbuch und Garantie
Um Verletzungen zu vermeiden, lesen Sie bitte die Gebrauchsanweisung vor der ersten Benutzung.
Redefi ning patient handling
Oxford
Journey
®
English
Manufacturer’s Contact Details
®
Oxford
EUROPE
Joerns Healthcare Ltd High Street, Wollaston
Stourbridge, West Midlands
Contents
1. The Oxford Journey Patient Lift ........................................................................................ 3
2. Introduction: About Your Lift.............................................................................................. 4
3. Assembly & Commissioning Instructions .......................................................................... 5
4. Sling Guide ....................................................................................................................... 10
5. Lifting With Your Oxford Journey ...................................................................................... 12
6. Operating Instructions....................................................................................................... 14
7. Safety Precautions............................................................................................................ 17
8. Charging Instructions ........................................................................................................ 19
9. Maintenance Schedule & Daily Check List....................................................................... 21
10. Technical Specifications.................................................................................................... 23
11. Warranty ........................................................................................................................... 26
DY8 4PS, UK
+44 (0) 1384 44 66 22
Fax: +44 (0) 1384 44 66 01
www.joerns.co.uk
2
294000.10050 Rev. B
English
1. The Oxford Journey Patient Lift
Oxford
Journey
®
Push Handle
Mast
Battery/
Control Pack
Hand
Control Unit
Kneepad
Adjustment
Lever
Rear Castor
(Braked)
READY FOR USE POSITION
Cow Horn Position Indicator
Cow Horn
Spreader Bar Attachment Hook
Electric Actuator
Adjustable Kneepad
Mast Release Lever (located on side of mast)
Front Castor (non-braked)
Removable Footy Tray
STORAGE POSITION
3
294000.10050 Rev. B
Oxford
Journey
®
English
2. Introduction: About Your Lift
The Oxford Journey is an electrically operated patient lift. Each Journey lift is fully assembled, load tested and certified before being packed/shipped.
The packing consists of a strong, purpose built carton to ensure the safe arrival of the lift.
A number of documents are supplied in a wallet, and packed with each lift and should be kept safely for future reference:
• TEST CERTIFICATE
• USER MANUAL
• DEALER GUARANTEE CARD (Europe only)
• CUSTOMER SATISFACTION CARD (Europe only)
• PACKING CHECK LIST
The TEST CERTIFICATE is an important document and will be required for your insurance records. It is valid for six months but after it has expired the lift should be inspected and serviced as per the maintenance schedule.
Your authorised dealer can carry out servicing and periodic testing for those countries where this is a requirement (Europe). Please ensure your lift is included in their maintenance schedule. If you are at all unsure what your local market servicing requirements are, please check with your dealer, a local government agency and/or Joerns Healthcare.
The CE mark:
4
294000.10050 Rev. B
The Oxford Journey carries the CE mark and complies with the following EC directives:
• Medical Device Directive (93/42/EEC)
• EMC Directive (89/336/EEC) (Electrics only)
• Low Voltage Directive (73/23/EEC) (Electrics only)
English
Oxford
Journey
3. Assembly & Commissioning Instructions
CARTON CONTENTS
Place the carton in a clear working area and open carefully. The carton contains:
Oxford JOURNEY LIFT
WALLET CONTAINING DOCUMENTS
HAND CONTROL
BATTERY PACK
CHARGING LEAD
DESK TOP CHARGER/STAND
WARNING
The Oxford Journey is heavy and will need to be lifted with care. You may need assistance to lift the Oxford Journey from the carton.
ASSEMBLY
The Oxford Journey is delivered in its folded/storage position; the following assembly process demonstrates the 3 easy steps required to take the Oxford Journey from its storage position to its ready for use position. This process is carried out with no additional tools required.
1. Remove all the parts from the carton and place on the floor, taking care to protect the finish
from damage.
®
Lift the Oxford Journey carefully from the carton. Lie the lift flat on the floor and ensure the rear castors are securely locked.
294000.10050 Rev. B
5
Oxford
Journey
®
English
2. To unfold the Oxford Journey into its ready-to-use position, raise the mast assembly upright. This
is achieved by pressing the mast release button located under the actuator (as shown). This will release the mast assembly and allow the mast to be raised. Using the top of the push handle, raise the mast to its upright position and locate the mast into the slot (1). Once the mast is firmly located, use the mast locking lever to secure the mast. This is achieved by pushing the mast locking lever down towards the mast surface (2). Finally, release braked castors at the rear and the Oxford Journey is ready for use (3).
1
2
3
CAUTION
Avoid trapping fingers. Keep fingers away from the end of the mast when inserting into the mast slot. Tighten the mast-locking device, and unlock the braked castors at the rear.
6
294000.10050 Rev. B
English
Journey
3. Adjust the cow horn mechanism into one of three positions to suit either the patient task and/or
environment. To adjust the cow horn, simply pull the trigger backwards towards the rear of the lift while holding the cow horn. Then select the desired position as indicated on the positioning decal (1) and release the trigger to lock. The lift is now ready for operation.
1
Position 1
Position 2
Position 3
Oxford
®
Position 1 Position 2 Position 3
Storage/Fold
NOTE: See page 12 for cow horn position guidelines.
DISASSEMBLY
To disassemble and store the Oxford Journey follow the four easy steps shown below; please note that no additional tools are required.
1. Lower the boom into its lowest possible position and adjust the cow horn to the storage/fold
position (as shown).
Storage/Fold
2. Ensure the rear castors are securely locked (1). Raise the knee pad to its upper most position (2).
1
2
7
294000.10050 Rev. B
Oxford
Journey
®
English
3. Unlock the mast-locking lever by pulling it outwards from the mast (1). Using the push handle lift the
mast upwards and then slowly push downwards (2), carefully folding the mast assembly towards the legs until you hear a “Click” (3). The “Click” indicates the mast is now in its locked position.
1
2
3
4. When folded, lift the Oxford Journey upright using the legs and push handle as a guide.
NOTE: If you wish to separate the mast and boom completely from the base and legs, undo the
mast-locking lever fully (remove pin assembly from mast) and lift the mast and boom completely free from the base. Be careful not to lose the mast lock lever and location spindle.
8
294000.10050 Rev. B
English
Journey
CAUTION
Care should be exercised when folding/unfolding the Oxford Journey as there is a possible danger of trapping the fingers etc. Please follow the instructions carefully and ask for assistance if you are unsure of the correct procedure.
ALWAYS CHECK THE FOLLOWING BEFORE OPERATION:
• The mast is fully locked into position (see assembly instructions, page 6).
• The legs of the lift open and close freely (Using foot pedals).
Oxford
®
• The power pack is fitted to the lift and the latch holding the power pack in place is fully engaged. A” Click” should be heard when it is in place.
• The red emergency stop button, located on the control box, is in the RUN (out) position.
9
294000.10050 Rev. B
Oxford
Journey
®
English
• The up and down buttons on the hand control lower and raise the boom correctly.
4. Sling Guide
The Oxford Journey is suitable for patients in the SITTING position. The slings suitable for this device are listed as follows:
* Oxford Transport sling (various sizes available) * Oxford Standing sling (various sizes available)
USER GUIDE FOR STANDAID SLINGS
Both the Transport and Standing sling are easy fit slings, suitable for standing and supporting. They are not a general purpose sling. Patients must always be assessed for suitability by a qualified person.
Transport Sling
Attachment Loop Straps; Shoulder
Chest Supports and Buckle
Attachment Loop Straps; Legs
Fitting Instructions
Feed the sling down the back of the patient leaving the top of the commode aperture at the base of the spine. Check the roll part of the sling is square across the patient’s back. Attach the support strap around the chest of the patient. This strap need not be tight. It is there to hold the sling in position while attaching the loops to the Standaid. It may be left off altogether if preferred. Ensure patient’s arms are on the outside of the sling (refer to Fig. C, page 13).
10
294000.10050 Rev. B
English
Raise the patient’s leg and feed the leg strap under and up between the legs. Ensure the sling is not twisted or creased under the thigh. Repeat this procedure for the other leg. Attach the loops on the roll parts of the sling to the white hooks at the end of the handgrips. Without crossing the loops on the leg straps, attach to left and right hooks on the lifting fork. You would normally use the middle of the three loops. The patient is now ready to be raised from the seat. Once clear of the seat, the patient will be more comfortable if lowered back in to the sitting position. Joerns Healthcare recommends that slings be checked regularly and particularly before use for signs of fraying or damage. Do not use slings that are worn or damaged.
Oxford
Journey
®
Standing Sling
Fitting Instructions
Place the sling down behind patients back between base of shoulder blades and bottom of rib cage. Attach the support straps around the front of the patient. This strap need not be tight. It is there to hold the sling in position whilst attaching the sling to the Standaid. It may be left off altogether if preferred. Ensure that the patient’s arms are outside the sling (refer to Fig. A, page 13)
NOTE: For detailed fitting instructions, please refer to the user guide supplied with each sling.
Attachment Loop Straps
Chest Supports and Buckle
WARNING
Joerns Healthcare recommends that slings be checked regularly and particularly before use for signs of fraying or damage. DO NOT use slings that are worn or damaged.
WARNING
Oxford RECOMMENDS THE USE OF GENUINE Oxford PARTS. Oxford slings and lifters are not designed to be interchangeable with other manufacturer’s products. Using other manufacturer’s products on Oxford products is potentially unsafe and could result in serious injury to patient and/or caregiver.
WARNING
Refer to maximum weight capacity of lift. Sling capacity is limited by the maximum capacity of the lift.
11
294000.10050 Rev. B
Oxford
Journey
®
English
5. Lifting With Your Oxford Journey
The Oxford Journey has an adjustable cow horn. This allows the carer to position the cow horn in a comfortable position to suit the patient or environment. The cow horn has 3 positions. Position 1 is more suitable for a large/taller patient, position 2 is more suitable for a medium/average size patient and position 3 is more suitable for a shorter/pediatric patient or when standing a patient from a low chair. (Please note, these are guidelines only, it may be necessary to adjust according to patient comfort). To adjust the cow horn, simply pull the trigger backwards towards the rear of the lift whilst holding the cow horn. Then select the desired position as indicated by the positioning decal and release trigger to lock. The cow horn has 3 alternative positions for lifting and a further one for the storage/fold position.
Cow Horn Lift Positions
Position 1
Position 2
Position 3
Position 1 Position 2 Position 3
Lifting from a sitting position
Select the most suitable cow horn position to suit the patient or environment. Once complete, position the Standaid so that the patient’s feet fit in the foot tray and the knees rest against the kneepad (adjust knee pad accordingly and fit safety belt if required). Attach the loops of the sling to the grey hooks at the end of the Oxford Journey handgrips. The patient’s hands should be placed on the handgrips (see Fig A or C). Prior to lifting make a visual check to ensure the loops of the sling are secure and in place. Then, push the UP button on hand control to raise the patient to the standing position (see Fig B or D).
12
294000.10050 Rev. B
Storage/Fold
English
Standing Sling:
TRANSPORT SLING:
Fig. A Fig. B
Oxford
Journey
®
Fig. C Fig. D
NOTE: Joerns Healthcare recommends a risk assessment be completed before carrying out your
lifting operation.
WARNING
Always utilise the foot tray when standing or seating a patient. Once the patient is in a standing position, the foot tray may be removed for gait training.
13
294000.10050 Rev. B
Oxford
Journey
®
English
6. Operating Instructions
Operating controls for the Oxford Journey lift
Operating Instructions
1. Leg Adjustment
The legs on the Oxford Journey are adjustable for width. The legs can be opened to enable access around armchairs or wheelchairs. For transferring and negotiating narrow doorways/ passages, the lift legs should be in the closed position. To achieve the adjustment, the leg adjuster pedal, located at the rear of the base, is compressed right (DOWN) to open the legs outwards and left (UP) to close the legs. The adjustment can be carried out with the patient in the lift, but whether loaded or unloaded the adjustment should be made when the lift is moving.
2. Castors and Braking
The lift has two braked castors, which can be applied for parking. When lifting, the castors should be left free and un-braked. The lift will then be able to move to its natural centre of gravity. If the brakes are applied, it is the patient that will swing to the centre of gravity and this may prove disconcerting and uncomfortable.
3. Raising & Lowering The Boom
A powerful electric actuator that is controlled by a simple hand control unit achieves the movement of the boom. The hand control has two buttons with directional arrows UP and DOWN . The actuator stops automatically at its limit of travel in both directions. The hand control plugs into a socket at the base of the control box.
4. Emergency Stop
The red Emergency Stop Button is located on the front of the control box and is activated by pressing it in. This will cut all power to the lift and will only be reset by twisting the button clockwise and releasing.
14
294000.10050 Rev. B
English
Oxford
Journey
5. Electrical Emergency Down/Up
Emergency lower (down) and raise (up) buttons are provided at the front of the control box. Inserting a ballpoint pen into the button-highlighted  operates these buttons. This will bring the boom up or down should the hand control fail at any time.
6. Mechanical Emergency Down
In the case of a complete electrical failure the electrical actuator is fitted with mechanical lowering device (RED BOSS). This will only operate when the lift is under load. The device must be pulled upwards to activate, and a slow descent will commence.
7. Batteries
A LOW VOLTAGE ALARM protects the batteries from deep discharge. This will sound when the batteries need recharging and the hand control is being operated. It will not sound independently of the hand control being operated. DO NOT IGNORE THIS WARNING ALARM. Complete the lifting operation and place the battery on charge (see charging instructions). The battery charge level is displayed by the indicator on the control box.
CAUTION
The battery, charger, hand control, control box and actuator should not to be opened by unauthorized personnel. (Contact your distributor for warranty and repairs).
®
8. Slings
The Oxford Journey is suitable for patients in the SITTING, position. The slings suitable for this device are listed as follows:
• Oxford Transport sling
• Oxford Standing sling
9. Knee pad adjustment
The Oxford Journey has an adjustable kneepad. It is recommended for safety and ergonomic reasons that any adjustment is carried out by holding the top of the adjustment handle. The range of travel is 10.2 inches (260mm). Adjustment is achieved by following two easy steps. STEP 1 turn the kneepad adjustment lever to the left to unlock. STEP 2 either push handle downwards or pull handle upwards to select correct position. Once the ideal position is found, simply turn the kneepad adjustment lever to the right to lock in place, NOTE: the lever can be operated from either side of the lift.
2
1
294000.10050 Rev. B
15
Oxford
Journey
®
English
10. Removable footplate
The Oxford Journey has a removable footplate. To remove the footplate, move to the front of the Oxford Journey and lift the footplate upward from the middle of the base assembly.
NOTE: Be careful when removing the footplate from its low-seated position as it is heavy. Always use appropriate moving and handling techniques.
WARNING
Always utilise the foot tray when standing or seating a patient. Once the patient is in a standing position, the foot tray may be removed for gait training.
11. Adjustable cow horn
The Oxford Journey has an adjustable cow horn. This allows the carer to position the cow horn in a comfortable position to suit the patient or environment. The cow horn has 3 positions. Position 1 is more suitable for a large/taller patient, position 2 is more suitable for a medium/average size patient and position 3 is more suitable for a shorter/pediatric patient or when standing a patient from a low chair. (Please note, these are guidelines only, it may be necessary to adjust according to patient comfort). To adjust the cow horn, simply pull the trigger backwards towards the rear of the lift whilst holding the cow horn. Then select the desired position as indicated by the positioning decal and release trigger to lock. The cow horn has 3 alternative positions for lifting and a further one for the storage/fold position.
Position 1 Position 2 Position 3
Cow Horn Lift Positions
16
294000.10050 Rev. B
Position 1
Position 2
Position 3
Storage/Fold
English
Oxford
Journey
7. Safety Precautions
Please read and follow the safety precautions listed below. The operation and use of Oxford patient lifts is simple and straightforward. Following these few basic safety precautions will make lifting operations easy and trouble free.
READ AND UNDERSTAND THE USER INSTRUCTION MANUAL BEFORE USING YOUR Oxford Journey
WARNING
ALWAYS plan your lifting operations before commencing.
ALWAYS carry out the DAILY CHECK LIST before using the lift.
ALWAYS familiarise yourself with the operating control and safety features of a lift before lifting a patient.
DO NOT use a sling unless it is recommended for use with the lift.
ALWAYS check the sling is suitable for the particular patient and is of the correct size and capacity.
NEVER use a sling, which is frayed or shows signs of damaged.
ALWAYS fit the sling according to the instructions provided (user instructions).
®
DO NOT exceed the safe working load.
ALWAYS check the safe working load of the lift is suitable for the weight of the patient.
ALWAYS carry out lifting operations according to the instructions in the user manual.
NEVER disconnect or bypass a control or safety feature because it seems easier to operate the lift.
DO NOT lift a patient with the castor brakes on. Always let the lift find the correct centre of gravity.
DO NOT attempt to maneuver the lift by pushing on the mast, boom or patient.
ALWAYS maneuver the lift with the handle / foot push pad provided.
ALWAYS lower the patient to the lowest comfortable position before transfers.
DO NOT push a loaded lift at speed, which exceeds a slow walking pace (3 Km/hour 0.8 metres/second).
DO NOT push the lift over uneven or rough ground. Particularly if loaded.
DO NOT attempt to push/pull a loaded lift over a floor obstruction.
294000.10050 Rev. B
17
Oxford
Journey
®
English
NEVER force an operating/safety control. All controls are easy to use and do not require excessive force.
DO NOT park a loaded lift on ANY sloping surface.
DO NOT use electric lifts in a shower.
DO NOT charge an electric lift in a bathroom or shower room.
DO NOT lift a patient unless you are trained and competent to do so.
DO NOT use the lift, or allow the lift to be used, for any other purpose.
DO NOT bump the lift down steps, loaded or unloaded.
DO NOT attempt to negotiate a loaded lift on a slope, which exceeds 1:12 (approximately 5 degrees).
DO NOT attempt to negotiate a slope without a second helper being present.
DO NOT use in a wet or corrosive environment such as poolside locations.
18
294000.10050 Rev. B
English
Oxford
Journey
8. Charging Instructions
The batteries are located in the power pack and are charged via an off board desktop charger unit.
®
Hand Control
Boom Raise
Lower Buttons
Battery Charge
Level Indicator
When the power pack needs charging, it can be removed from the lift and fitted to an off board charging unit. The battery charge level is displayed by the indicator on the control box.
Joerns Healthcare recommends an additional battery pack is purchased, so that one pack can be on charge at all times
1. Remove the power pack from the lift. A simple latch at the top of the power pack retains the
pack. Lift the latch and the power pack will be released.
2. Fit the power pack to the charging unit. The location and latching of the power pack to the
charger is the same system as used on the lift.
3. Plug the charger mains plug into a suitable mains outlet and switch the mains supply ON. (If
applicable).
4. Charging is automatic and will fully charge the batteries over a period of eight to twelve hours.
Note: Even if the charger is left plugged in for extended periods it will not allow the batteries to overcharge.
Removable Battery Pack
Control Box
Emergency Stop Button
Boom Raise/ Lower Buttons
5. To return the lift to service, switch OFF (if applicable) the mains supply and remove the power
pack from the charger. Fit the power pack to the lift and make sure the latch holding the pack in place is fully engaged. “Click” in place. The charging of Oxford electric lifts is simple and straightforward, but it is important to follow the charging instructions closely. Please pay particular attention to the following points; they will help you avoid problems with discharged batteries.
WARNING
The battery, charger, hand control & control box are NOT to be opened by unauthorized personnel. (Contact your distributor for warranty and repairs).
WARNING
DO NOT touch battery/charger terminals.
294000.10050 Rev. B
19
Oxford
Journey
®
English
CAUTION
KEEP the batteries fully charged. Place the battery on charge whenever it is not in use. If it is more convenient to do so, place on charge every night. The charger will not allow the batteries to overcharge.
CAUTION
NEVER run the batteries completely flat. As soon as the audible warning sounds, complete the lifting operation in hand and place on charge.
CAUTION
NEVER store the power pack for long periods without regular charging throughout the storage period.
CAUTION
ALWAYS make sure the mains power to the charger is switched off before connecting or disconnecting the power pack. (UK EU Requirement).
CAUTION
NEVER leave the power pack plugged in to the charger with the mains power off. (UK EU Requirement).
WARNING
Do not charge an electric lift in a bathroom or shower room.
WARNING
Do NOT leave charger switched on with battery disconnected (UK EU Requirement).
20
294000.10050 Rev. B
English
Oxford
Journey
9. Maintenance Schedule & Daily Check List
All Oxford products are designed for minimum maintenance, however some safety checks and procedures are required. Schedules of DAILY tasks are detailed below. Daily checks and a six monthly service, inspection and test will ensure a lift is kept in optimum safe working condition. A list of spare parts is available upon request.
The LOAD TEST and certification should only be carried out by qualified personnel or an authorised service agent / dealer.
DAILY CHECK LIST: Joerns Healthcare strongly recommends the following checks be carried out on a daily basis and before using lift.
• MAKE sure the lift moves freely on its castors.
• EXAMINE the spreader bar (cow horns) is firmly attached to the boom.
• EXAMINE the sling hooks and attachment clips on the spreader bar and boom for excessive wear.
• MAKE sure the legs open and close correctly.
• OPERATE the hand control to confirm the boom raises and lowers satisfactorily.
• CHECK the operation of the emergency stop button.
• EXAMINE slings for fraying or other damage. DO NOT use any sling if damaged.
• CONFIRM the lift is not giving a low battery alarm when the hand control is operated. If the alarm sounds, DO NOT use and place the battery on charge immediately.
®
MAINTENANCE, INSPECTION AND TEST
Joerns Healthcare recommends that a thorough inspection and test of the Oxford Journey lift and lifting accessories and slings is carried out on a regular basis.
Inspection frequency varies from country to country so you must check with your dealer or local government agency as appropriate regarding how often an inspection is required. The examination and test should be conducted according to the recommendations and procedures below. Joerns Healthcare recommends maintenance, inspection and certified testing is carried out by an authorized service agent / dealers only.
NOTE: These recommendations are in compliance with the requirements of 1998 No2307 Health and Safety: The Lifting Operations and Lifting Equipment Regulations 1998. This is a UK regulation. Outside the UK please check your local country requirements.
294000.10050 Rev. B
21
Oxford
®
Journey
*THESE CHECKS SHOULD INCLUDE:
Initially
1. BOOM: Check the attachment of the boom to the mast. Make sure there
is only minimal side movement of the boom and the boom is free to rotate on the boom bearing.
2. SLING ATTACHMENT POINTS: Examine the sling hooks and attachment
clips on the spreader bar and boom for excessive wear.
3. MAST: Check the operation of the mast-locking device. Make sure the
mast fully engages into the socket.
4. COW HORN: Check cow horn is engaged and in correct position.  
5. ACTUATOR: The actuator should require no maintenance other than
checking for correct operation and listening for unusual noise.
6. KNEE PAD: Check knee pad adjuster is fastened securely.  
7. POWER PACK: Check the function of the emergency stop button and
emergency lower.
8. BATTERIES: The batteries are housed in the power pack and should not
require maintenance other than the regular charging as detailed in the charging instructions. Check that the connections remain clean.
9. BATTERIES (Charging): Confirm the lift is not giving a low battery alarm
when the hand control is operated. If the alarm sounds, do not use and   place the battery on charge immediately.
10. LEG ADJUSTMENT: Check the legs operate in both full extensions
(inward/outward).
11. CASTORS: Check all castors for firm attachment to the legs.
Check for free rotation of the castor and the wheels.
12. CLEANING: Using a damp cloth, wipe clean with ordinary soap and water
and/or any hard surface disinfectant. Harsh chemical cleaners or abrasives should be avoided as these may damage the surface finish of the lift. Avoid wetting any of the electrical parts.
13. LOAD TEST: The load test should be carried out in accordance with the
local market test procedures. It is strongly recommended the testing is carried out by an authorised service dealer.
14. BASE AND WHEELS: Ensure base is even and level
(all four wheels are on the floor).
15. SLINGS: Check for wear and fraying.
16. LUBRICATION: Lubricate pivot joints with a silicone based oil, including
mast and boom connections, pedal assembly, spreader bar joint (only if required).
17. HAND SET: Ensure plugged fully into controller.  
 
 
 
 
 
 
 
English
Before Use
Service
Intervals
22
294000.10050 Rev. B
English
10. Technical Specifications
Safe Working Load .........................................................341 lbs 155 kgs
Maximum Overall Length ................................................39.4 inches 1000 mm
Minimum Overall Length .................................................36.8 inches 935 mm
Maximum Overall Height .................................................63 inches 1600 mm
Minimum Overall Height ..................................................44.5 inches 1130 mm
Maximum Height to attachment point ..............................60.2 inches 1530 mm
Minimum Height to attachment point ...............................28.4 inches 720 mm
Turning Radius ................................................................45.1 inches 1145 mm
Legs Open - External Width ........................................... 38.2inches 970 mm
Legs Open - Internal Width .............................................34.5 inches 875 mm
Legs Closed - External Width ........................................27.0 inches 685 mm
Legs Closed - Internal Width ..........................................22.2 inches 590 mm
Widest Point (between support handles) ........................26.8 inches 680 mm
Overall Height of Legs .....................................................4.3 inches 110 mm
Ground Clearance ...........................................................1.2 inches 30 mm
Front Twin Castors ..........................................................3.0 inches 75 mm
Rear Braked Castors .......................................................4.0 inches 100 mm
Oxford
Journey
®
Weights
Mast, Base & Boom Assembly ......................................82.4 lbs 37.4 kg
Power Pack .....................................................................6.2 lbs 2.8 kg
Total ..............................................................................88.6 lbs 40.2 kg
Base Assembly (not inc battery) ......................................30.2 lbs 13.7 kg
Mast & Boom (not inc battery) ......................................42.3 lbs 19.2 kg
Foot Tray .........................................................................9.9 lbs 4.5 kg
NOTE: Manufacturing tolerances apply to all dimensions.
23
294000.10050 Rev. B
Oxford
®
Journey
ELECTRICAL SPECIFICATIONS:
BATTERIES .....................................................................24 volt Rechargeable sealed lead acid type
BATTERY CAPACITY ......................................................3.2 Ampere hours
CHARGER RATED INPUT ..............................................100 - 240 V AC/ 50/60 Hz
CHARGER RATED OUTPUT ..........................................29.5 VDC, Max. 19 W
Electric Shock Protection
CHARGER .......................................................................CLASS II (EN 60601-1)
LIFT .................................................................................INTERNAL POWER SOURCE
Degree of Shock Protection
CHARGER .......................................................................TYPE B (EN 60601-1)
LIFT .................................................................................TYPE B (EN 60601-1)
ENVIRONMENTAL CONDITIONS:
Outside this environment functionality and safety may be compromised.
Operating:
Temperature ...................................................................5°C to 40°C
Relative humidity .............................................................20% to 90% @ 30°C - not condensing
English
Storage:
Temperature ........................................... ........................-10°C to +50°C
Relative humidity .............................................................20% to 90% @ 30°C - not condensing
IP RATINGS
Control Box .....................................................................IP43
Actuator ...........................................................................IP54
Off Board Charger .......................................................... IP65
Battery ............................................................................IP65
Handset ..........................................................................IP65
DUTY CYCLES
Actuator ...........................................................................10% (2 min./18 min.)
Charger ..........................................................................Approx. 4 hrs.
ACOUSTICS
A-Weighted sound power level ......................................60 dB (A)
24
294000.10050 Rev. B
English
Oxford
Journey
KEY SYMBOLS:
The following symbols are used on the charger, control unit and battery:
Type B equipment, as per EN 60601-1
Class 2 equipment
The disposal of the charging and control unit should not be mixed with general household waste
The disposal of batteries should not be mixed with general household waste.
®
The disposal of electronics should not be mixed with general household waste
For indoor use
ATTENTION, consult accompanying documents.
WEE Producers registration number WEE/GG0464RZ
25
294000.10050 Rev. B
Oxford
Journey
®
English
11. Warranty
Joerns Healthcare has an established network of reputable distributors, dealers and service providers who will be pleased to handle all your purchasing, warranty, repair and maintenance enquiries.
Our products are guaranteed for a period of 24 months from the date of manufacture or 24 months from the date of purchase if commissioned by an authorised dealer. This guarantee covers the lift’s major structure, actuator and control box, handset, and battery for manufacturing defects/failures.
We recommend that all of our products are commissioned by your dealer and are supported by them for future servicing. The dealer or distributor operates the warranty programme; so it is important to keep a record of their name, address and telephone number so they can be contacted should any problem arise (Europe only).
Failure to comply to the lift’s servicing schedule may result in your warranty being invalid.
If you are in doubt where your lift was purchased, Joerns Healthcare can trace the supplier if you quote the serial number of the lift.
REMEMBER Contact your distributor for purchases, warranty, repairs, servicing and certified maintenance.
Your Dealer/Distributor:
26
294000.10050 Rev. B
English
Oxford
Journey
®
294000.10050 Rev. B
27
Oxford
Journey
®
Français
Coordonnées du fabricant
®
Oxford
EUROPE
Joerns Healthcare Ltd High Street, Wollaston
Stourbridge, West Midlands
Table des matières
1. Lève-personne Oxford Journey ........................................................................................ 3
2. Introduction : A propos de votre lève-personne ............................................................... 4
3. Instructions de montage et de mise en service ................................................................ 5
4. Guide des courroies ......................................................................................................... 10
5. Soulever le patient à l’aide du lève-personne Oxford Journey ........................................ 12
6. Instructions de fonctionnement ......................................................................................... 14
7. Consignes de sécurité ...................................................................................................... 17
8. Instructions de charge ...................................................................................................... 19
9. Périodicité d’entretien et liste de contrôle quotidien ......................................................... 21
10. Spécifications techniques ................................................................................................. 23
11. Garantie ............................................................................................................................ 26
DY8 4PS, UK
+44 (0) 1384 44 66 22
Fax: +44 (0) 1384 44 66 01
www.joerns.co.uk
28
294000.10050 Rev. B
Français
1. Lève-personne Oxford Journey
Oxford
Journey
®
Poignée de
pousse
Mât
Ensemble Batterie/
Commande
Unité de commande
manuelle
Manette de
réglage du
protège-genou
Roulette arrière
(freinée)
POSITION PRÊT À L’EMPLOI
Indicateur de position des cornes de vache
Corne de vache
Crochet d’attache de la barre d’écartement
Actionneur électrique
Protège-genou réglable
Levier de relâche du mât (situé sur le côté du mât)
Roulette avant (Non-freinée)
Cale-pied amovible
POSITION D’ENTREPOSAGE
29
294000.10050 Rev. B
Oxford
®
Journey
2. Introduction : A propos de votre lève-personne
Le lève-personne Oxford Journey est électrique. Chaque lève-personne Journey est entièrement monté, soumis à un essai de charge et certifié avant d’être emballé/expédié.
L’emballage se compose d’une boîte en carton robuste construite spécialement pour garantir l’arrivée de l’appareil intact à destination.
L’emballage de chaque lève-personne comprend une pochette contenant un certain nombre de documents qui doivent être conservés en lieu sûr au cas où ils devraient être consultés ultérieurement.
• CERTIFICAT D’ESSAI
• MANUEL D’UTILISATION
• CARTE DE GARANTIE DU DISTRIBUTEUR (Europe uniquement)
• CARTE DE SATISFACTION (Europe uniquement)
• LISTE DE VERIFICATIONS D’EMBALLAGE
Le CERTIFICAT D’ESSAI est un document important qui doit être conservé dans votre dossier assurance. Il est valide pendant six mois mais, après son expiration, le lève-personne doit être inspecté et entretenu selon le calendrier d’entretien.
L’entretien et les essais périodiques peuvent être effectués par votre revendeur agréé en cas de besoin (Europe). Assurez-vous que votre lève-personne est inscrit dans le calendrier d’entretien de votre revendeur. En cas d’incertitude concernant les normes d’entretien locales, veuillez vous renseigner auprès d’un organisme gouvernemental local et / ou de Joerns Healthcare.
Français
Marque CE :
30
294000.10050 Rev. B
Le lève-personne Oxford Journey porte le marquage CE et est conforme aux directives européennes suivantes :
• Directive « Dispositifs médicaux » (93/42/CEE)
• Directive « Compatibilité électromagnétique » (89/336/CEE) (modèles électriques uniquement)
• Directive « Basse tension » (73/23/CEE) (modèles électriques uniquement)
Loading...
+ 78 hidden pages