A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR
FIRE PIT FOR PROPANE AND *NATURAL GAS
* Select link below to download French instructions.
* Sélectionnezlelienci‐dessouspour
téléchargerlesinstructionsfrançaises.
http://www.owlee.com/technical-information.aspx
WARNING: FOR OUTDOOR USE ONLY
Report #521-O-02-5
Tested & Certified to
ANSI Z21.97-2014/CSA 2.41-2014
CGA 2.17-M91 (R2009)
TM
* Needs Conversion Kit
CODE AND SUPPLY REQUIREMENTS: When an appliance is for connection to a fixed piping system, the installation
must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA
54, International Fuel Gas Code, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and
Handling Code, B149.2, as applicable.
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
An LP-cylinder not connected for use shall not be stored within 60" of this
unit or any other appliance.
WARNING
Improper installation, adjustment,
alteration, service or maintenance can
cause injury or property damage. Read
the installation, operating and
maintenance instructions thoroughly
before installing or servicing this
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and immediately call
your gas supplier or fire department.
equipment.
This appliance is designed as an
“attended appliance”. Adults must be
present when the unit is operating.
DO NOT leave this unit burning when
unattended. If this product i s left burning
unattended it may cause damage or
serious injury.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car, or
home
INSTALLER - Owner’s Manual must be left with
the consumer for future reference.
CONSUMER – Owner’s Manual must be saved
for future reference.
V2-070515
OUTDOOR FIRE PIT - TABLE OF CONTENTS
Cover - Important Safety Information1
Table Of Contents2
Important Safety Information
Minimum Clearances to Combustibles2
Pre-Installation & Preparation Guidelines3
Installation Information
Connecting the Gas to the Fire Pit5
Certified Media List6
Glass Media Installation6
Gem, Mirriored, Tumbled Glass and Ceramic Log Installation7
Ceramic Rock and Sphere Media Installation8
Operation Instructions9
Lighting Instructions9
Operating Instructions4
Conversion to a Different Gas Type10
IMPORTANT SAFETY INFORMATION
READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.
If not installed and used correctly per these instructions,
this product can cause serious injury and or property damage
.
CAUTION: INSTALLATION, MODIFICATION AND REPAIR MUST BE DONE BY
A CERTIFIED, PROFESSIONAL TECHNICIAN or LICENCED PLUMBER.
Be sure you understand all safety precautions and warnings contained in this manual.
If you have any questions, please contact O.W. Lee at (800) 776-9533
A.
CHECK STATE AND LOCAL CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN
YOUR LOCALITY BEFORE INSTALLATION.
B.
FOR OUTDOOR USE ONLY. THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM CENTER OF BURNER
TO ANY COMBUSTIBLE WALLS, CEILINGS, OR MATERIAL.
C.
When shutting the unit down—be sure to TURN THE CONTROL VALVE FULLY OFF ON THE FIRE PIT and
close the valve on the PROPANE TANK or NATURAL GAS supply.
D.
WARNING: CA RBON MONOXIDE POISONING MAY LEAD TO DEATH. DO NOT MODIFY THIS OUTDOOR
FIRE PIT OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL.
Any other change may be dangerous. Improper installation or use of your Outdoor Fire Pit can cause serious
injury or death from fire, burns, explosions or carbon monoxide poisoning.
MINIMUM CLEARANCE TO COMBUSTIBLES
MINIMUM OF 60” (1.5 m) CLEARANCE ABOVE THE
OUTDOOR FIRE PIT IF INSTALLED UNDER CEILING OR
60” (1.5 m)
CLEARANCE
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION
NOTE
OVERHANG
60” (1.5 m)
CLEARANCE
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION
Clearances to Combustible Construction:
Sidewalls: 60” (1.5 m) from center of unit (Figure 1)
Ceiling: 60” (1.5 m) from top of unit to ceiling or overhang
Flooring: 0” – Can be installed on deck, slab, floor, etc.
The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this Outdoor
Fire Pit. THERE MUST BE AT LEAST 60” of clearance
from the center of the unit to any combustible sidewalls,
ceilings, or material.
Figure 1
Page 2
IMPORTANT SAFETY INFORMATION
g
,
j
Any
A.
Before installing this Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.
MINIMUM CLEARANCES
BE AT LEAST 60” (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.
B.
The Outdoor Fire Pit is for outdoor use only. DO NOT install or use this appliance inside a building,
garage, or any other enclosed area including recreational vehicles and/or boats. This unit must be
installed in such a manner that proper air ventilation is maintained without obstruction at all times, and
durin
C.
CHECK GAS TYPE (natural gas or propane): The gas supply you intend to use may not be the same as that
stated on your outdoor rating plate. THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANEGAS. If the
gas supply is different, or you wish to change to natural gas, you MUST have the Fire Pit Converted (method described on page 8) to the gas type you intend to use, by a qualified, professional technician. If you are
unsure
D.
DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE
MAXIMUM.
E.
FOR NATURAL GAS: The minimum inlet gas supply pressure for purposes of input adjustment is 5 inches (127
mm) water column and maximum inlet gas supply pressure is 10 inchesFOR PROPANE: The minimum inlet gas supply pressure for purposes of input adjustment is 8 inches
(203 mm) water column and the maximum inlet gas supply pressure is 13 inches (330 mm) water column.
DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS
EXCEEDED.
all weather conditions.
contact your dealer for assistance.
must be maintained when you install this Outdoor Fire Pit. THERE MUST
(254 mm) water column.
F.
Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr). Undue
pressure loss will occur if the pipe is too small or the run is too long.
G.
Casual Fireside Fire Pits are suitable for installation from 0 - 4500 ft. without modification.
If the Outdoor Fire Pit is connected to Natural Gas, its main gas valve must be disconnected from the gas supply
H.
piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5kPa).
If the Outdoor Fire Pit is connected to Natural Gas, it must be isolated from the gas supply piping system by
I.
closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5kPa).
J.
INSTALLER NOTE: This unit should be installed so that it can be removed at a later date for service.
K.
GAS SUPPLY PLUMBING REQUIREMENTS
Apply only joint compounds that are resistant to all gasses on all male pipe fittings. Make sure to tighten every
oint securely. Do not use pipe joint compound to connect flare fittings.
L.
Propane Regulator Hose: Always inspect the condition of the propane regulator hose before each operation.
signs of excessive abrasion MUST BE REPLACED. Contact your local dealer for replacement part
M.
Location Regulator Hose (when used): The propane regulator hose is located inside the fire pit door panel.
When installed, make sure the hose is secured inside the unit and DOES NOT TOUCH THE BURNER PAN.
SAFETY NOTE: An external on/off valve in the gas line is required for safety when your Outdoor
Fire Pit is not in use. It also provides for convenient maintenance and repair.