WARNING: FOR OUTDOOR USE ONLY
Installation and service must be performed by a qualified installer, service agency, or the gas supplier
READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.
If the information in this manual is not followed exactly, a fire or explosion may result causing
personal injury, death or property damage.
(Requires Conversion Kit)
Report #14661-1G
Tested & Certified to
CGA 2.17-M91 (R2017)
APPLIANCE BTU RATING
BUILDING CODE AND FIXED PIPING SUPPLY REQUIREMENTS: When an appliance is connected to a fixed gas piping supply
system, the installation must conform to local building codes, or in the absence of local building codes, to the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, International Fuel Gas Code, Natural Gas and Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2, as applicable.
WARNING
Improper installation, adjustment, alteration, service or maintenance of this gas appliance can cause
injury, death or property damage. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this gas appliance.
WARNING
To avoid risk of fire or explosion. Do Not store or use gasoline, or other flammable vapors and liquids, in
the vicinity of this or any other gas appliance. An LP-cylinder not connected for use shall not be stored in
the vicinity of this or any other gas appliance.
DANGER
FIRE OR EXPLOSION HAZARD
If you smell a rotten egg odor immediately
1. Shut off gas supply to the appliance.
2. Extinguish any open flame.
3. If odor continues, leave the area immediately.
4. After leaving the area, call your gas supplier
or fire department.
This gas appliance is designed as an “attended appliance”. Adults must be present when the unit is
operating/burning. DO NOT leave this unit operating/burning when unattended.
operating/burning and unattended it may cause serious injury, death and or property damage.
:
Failure to follow these instructions
could result in fire or explosion,
which could cause personal injury,
death or property damage,
If this product is left
CARBON MONOXIDE HAZARD
DANGER
This appliance can produce carbon monoxide
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space
such as a camper, tent, car or home
INSTALLER - Leave this manual with the
appliance.
CONSUMER – Retain this manual for
future reference.
.
V5-100118A
OUTDOOR FIRE PIT - TABLE OF CONTENTS
Table of Contents
Cover - Important Safety Information1
Important Safety Information and
Minimum Clearances to Combustibles2
Pre-Installation & Preparation Guidelines3
Important Safety Information4
Installation Information
Connecting the Gas to the Fire Pit5
Propane Tank Information6
Media Placement and Replacement Parts List
Certified Media List7
Gem, Mirrored, Crushed Glass and Ceramic Log Installation8
Ceramic Rock Media Installation9
Trouble Shooting Guide10
Warranty Information11
Operation Instructions
Lighting Instructions12
Propsition 65 Public Warning13
Conversion to a Different Gas Type14
IMPORTANT SAFETY INFORMATION
READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.
If not installed and used correctly per these instructions,
this product can cause serious injury, death, and or property damage and may void the warranty.
CAUTION: FIXED PIPING GAS SUPPLY INSTALLATION, AND REPAIRS MUST BE DONE BY
A CERTIFIED PROFESSIONAL TECHNICIAN or LICENSED PLUMBER.
Be sure you understand all safety precautions and warnings contained in this manual.
If you have any questions, please contact O.W. Lee at (800) 776-9533
CHECK STATE AND LOCAL BUILDING CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN
A.
YOUR LOCALITY BEFORE INSTALLATION.
FOR OUTDOOR USE ONLY. THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM CENTER OF BURNER TO ANY
B.
COMBUSTIBLE WALLS, CEILINGS, OR MATERIAL.
WHEN SHUTTING OFF THE UNIT — BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY OFF
C.
POSITION ON THE FIRE PIT and CLOSE THE VALVE ON THE PROPANE TANK or NATURAL GAS SUPPLY LINE.
WARNING:
D.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH. DO NOT MODIFY THIS OUTDOOR FIRE PIT
OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL.
IMPROPER INSTALLATION OR USE OF YOUR OUTDOOR FIRE PIT CAN CAUSE SERIOUS INJURY, DEATH, AND OR
E.
PROPERTY DAMAGE FROM FIRE, BURNS, EXPLOSIONS OR CARBON MONOXIDE POISONING.
MINIMUM CLEARANCE TO COMBUSTIBLES
MINIMUM OF 60” (1.5 m) CLEARANCE ABOVE TH E
OUTDOOR FIRE PIT IF INSTALLED UNDER CEILING OR
60” (1.5 m)
CLEARANCE
NOTE
OVERHANG
60” (1.5 m)
CLEARANCE
Clearances to Combustible Construction:
Sidewalls: 60” (1.5 m) from center of unit (Figure 1)
Ceiling: 60” (1.5 m) from top of unit to ceiling or overhang
Flooring: 0” – Can be installed on deck, slab, floor, etc.
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION
Figure 1
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION
Page 2
The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this Outdoor Fire
Pit. THERE MUST BE AT LEAST 60” of clearance from the
center of the unit to any combustible sidewalls, ceilings, or
material.
IMPORTANT SAFETY INFORMATION
Pre-Installation & Preparation Guidelines
Before installing the Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.
A.
MINIMUM CLEARANCES
BE AT LEAST 60” (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.
The Outdoor Fire Pit is for outdoor use only. DO NOT install or use this appliance inside a building,
B.
garage, or any other enclosed area or structure including recreational vehicles, boats & sheds. This unit must be
installed in such a manner that proper air ventilation is maintained without obstruction at all times, and during all
weather conditions.
CHECK GAS TYPE (Natural Gas or Propane): The gas supply you intend to use may not be the same that your fire pit was
C.
setup for or is stated on your outdoor rating plate. THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANEGAS. If
the gas supply is different, or you wish to change to Natural Gas, you MUST have the Fire Pit Converted (directions to
convert can be found on page 14) to the gas type you intend to use. Any gas type conversion should be performed
by a qualified, professional technician or licensed plumber. If you are unsure, contact your dealer for assistance.
D.
DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE MAXIMUM.
GAS PRESSURE REQUIREMENTS: FOR NATURAL GAS:
E.
The minimum inlet gas supply pressure for purposes of input adjustment is 3.5 inches (127 mm) water column and maximum
inlet gas supply pressure is 10 inchesFOR PROPANE: The minimum inlet gas supply pressure for purposes of input adjustment is 8 inches
(203 mm) water column and the maximum inlet gas supply pressure is 13 inches (330 mm) water column.
MANIFOLD PRESSURE REQUIREMENT: Liquid Propane 9.5 (241.3mm) / Natural Gas 2.5 (63.5mm) of pressure.
DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED.
must be maintained when you install this Outdoor Fire Pit. THERE MUST
(254 mm) water column.
F.
Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr). Undue
pressure loss will occur if the pipe is too small or the run is too long.
Casual Fireside Fire Pits are suitable for installation from 0 - 4,500 ft. elevation without modification.
G.
H.
If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve
installed before the fire pit and it must be closed during any pressure testing of the system at test pressures in excess of ½
psi (3.5kPa).
I.
If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve
installed before the fire pit must be closed during any pressure testing of the system at test pressures equal to or less than ½
psi (3.5kPa).
INSTALLER NOTE: This unit should be installed so that it can be removed at a later date for service.
J.
K.
GAS SUPPLY PLUMBING REQUIREMENTS
Apply only joint compounds that are resistant to all gasses on all male pipe fittings. Make sure to tighten every joint securely.
DO NOT use pipe joint compound to connect flare fittings.
Propane Regulator Hose: Always inspect the condition of the propane regulator hose before each operation. Any signs of
L.
excessive abrasion the hose MUST BE REPLACED. Contact your local dealer for replacement part #COM0589
Propane Regulator Hose (when used): The propane regulator hose is located inside the fire pit door panel. When
M.
installed, make sure the hose is secured inside the unit and DOES NOT TOUCH THE BURNER PAN.
N.
Note: The Use Of A Third Party Fire Pit Top, Media and or Components Will Void the LABTEST Certification
and O.W Lee Warranty.
O.
SAFETY NOTE: Fire pits connected to a fixed piped gas line, require a second gas shut off valve. The valve must be kept in
the off position when the fire pit is not in use. The secondary valve shuts off the gas supply to the fire pit and allows for
maintenance and repair.
Page 3
IMPORTANT SAFETY INFORMATION
WARNING: YOUNG CHILDREN SHOULD ALWAYS BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE AREA OF
A.
THIS APPLIANCE and IT IS IN USE. SERIOUS INJURY OR DEATH MAY OCCUR
WARNING: DO NOT sit or place any part of the body or combustible materials including hair near the Fire Pit Flame.
B.
WARNING: Children and adults should be alerted to the hazard of high surface temperatures and should stay away to
C.
avoid burns or clothing ignition.
WARNING: Every time you use your Fire Pit make sure that the area around the Fire Pit is clear of ALL flammable items
D.
such as yard debris, wood, etc. and any flammable vapor producing or flammable liquid items such as gasoline, etc.
WARNING: HOT WHILE IN OPERATION AND FOR AT LEAST A HALF HOUR FOLLOWING OPERATION.
E.
WARNING: Children must be carefully supervised when in the vicinity of this appliance. Serious injur or death may occur.
F.
WARNING: DO NOT throw trash, paper, plastics or any other flammable materials into your Fire Pit.
G.
WARNING: DO NOT leave fire pit lit when unattended.
H.
WARNING: DO NOT operate this Fire Pit in the rain.
I.
J.WARNING: DO NOT BURN SOLID FUEL IN THIS FIRE PIT.
WARNING: "Improper installation, adjustment, alteration, service or maintenance can cause injury, death or property
K.
damage. Read the installation, operation, and maintance instructions thoroughly before installing or servicing this
equipment"
DO NOT continue using your FIRE PIT if you smell a rotten egg odor or have headaches, nausea or dizziness.
L.
DO NOT store any combustible materials, gasoline, or any other flammable vapors/liquids within 60 inches of your Fire Pit.
M.
Provide adequate clearance for servicing and operation.
WARNING: Clothing or other flammable materials should not be hung from the appliance or place on or near the
N.
DO NOT use this appliance if any part of it has been under water. Call a qualified service technician to inspect the appliance
O.
and to replace any part of the control system and any gas control part which has been under water before using.
Installation and repair should be done by a qualified service technician or licensed plumber. Open the door on the unit to
P.
gain access for inspection.
To reduce the risk of explosion, the appliance should be inspected before each use and at least annually by a qualified
Q.
service technician. More frequent cleaning maybe required as necessary. It is imperative that the control compartment, burner
and air passageways of the gas appliance are kept clean.
The burner must be replaced prior to the appliance being put into operation if it is evident that the burner is damaged.
R.
Replacement burner #COM0568 manufactured by O.W. Lee Company, 1822 E. Francis Street, Ontario CA 91761
Periodically make a visual check of the burner flame to make sure it has not considerably changed in height or coloration since
S.
last being used. Any significant change in flame height or coloration is a sign that unit needs to be inspected and serviced or
cleaned as required in order to maintain proper safe operation.
Cleaning of appliance – Remove lava rock or glass pieces, clean burner with soap and water and dry thoroughly before lighting
T.
Clean lava rock or glass pieces with water and dry thoroughly before lighting. Remove any spider webs from inside the unit.
.
Page 4
CONNECTING AN LP-GAS CYLINDER/PROPANE TANK TO THE FIRE PIT
IMPORTANT
BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT
SAFETY INFORMATION IN THIS OWNER'S MANUAL
A.Important WARNINGS and Safety Information (Pages 1, 2, 3, 4)
B.Minimum Clearance to Combustibles (Page 2)
THE LP-GAS CYLINDER (Propane Tank) INFORMATION:
1.
Propane Cylinder Size - Capacity: 20 Lbs. (9kg) or 4.7 Gallons (17.8 Liters) of Propane
DO NOT OVERFILL
The LP-Gas Cylinder(s) to be used must be constructed and marked in accordance with the U.S. Department of
2.
Transportation (D.O.T.) Specifications for LP-Gas Cylinders or the Standard for Cylinders, Spheres and Tubes for Transportation
of Dangerous Goods and Commission, CAN/CSA-B339 as applicable.
--Use cylinders approved for your area such as “Blue Rhino” or “AmeriGas” with this appliance. Other cylinders may be
acceptable for use with the appliance provided they can be mounted to the appliance using the cylinder retention devise provided.
(See illustration above.)
--The LP-Gas Cylinder to be used must be provided with a listed overfilling prevention device (OPD) and with a cylinder
connection device compatible with the connection for the appliance.
3. Make sure the appliance is NOT in use, and turn OFF the gas at the supply LP-Gas Cylinder Valve.
The LP-Gas Cylinder must be disconnected when the appliance is not in use.4.
The LP-Gas Cylinders must be stored outdoors in a well-ventilated area out of the reach of children & at Least 60 inches away for
5.
the fire pit. Disconnected cylinders must have threaded valve caps tightly installed and must not be stored in any building, garage,
or other enclosed area.
6. The LP-Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal.
BEFORE INSTALLATION, BE SURE THE LP-GAS CYLINDER/PROPANE TANKS VALVE IS CLOSED.
When connecting the regulator to the tank valve, make sure the coupling nut does not cross-thread on the tank valve.
Cross-threading the regulator nut to the tank valve may cause a leak.
Turn on the gas to the burner system and test for leaks with soapy water solution.
(Never use an open flame for testing). If a leak is found, re-connect the regulator coupling nut and tighten until no leaks are detected.
The hose and burner should be inspected before each use of the appliance.
The hose assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive abrasion or wear,
or if the hose is damaged. The replacement hose must be specified by the manufacturer.
Page 5
y
DANGER - FLAMMABLE GAS UNDER PRESSURE
LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED
CAUSING SERIOUS BODILY INJURY OR DEATH.
CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF
THIS CYLINDER OR UNUSED LP-GAS.
WARNING - FOR OUTDOOR USE ONLY*
DO NOT USE OR STORE CYLINDER IN A BUILDING, GARAGE
OR ENCLOSED AREA.
WARNINGWHEN CONNECTING FOR USE:
Know the odor of LP-gas. If you hear, see or smell
leaking LP-gas, immediately get everyone away
from the cylinder and call the Fire Department. Do
not attempt repairs.
Caution your LP-gas supplier to
Be certain cylinder is purged of trapped air prior to
first filling.
Be certain not to over fill the cylinder.
Be certain cylinder requalification date is checked.
Use onl
Read and follow the manufacturer's instructions.
Consult manufacturer's instructions concerning
the cylinder connection provided with your
Be sure the regulator vent is not pointing up.
Turn off all of the valves on the appliance.
in compliance with applicable codes.
LP-gas is heavier than air and may settle in low
places while dissipating.
Contact with the liquid contents of the cylinder
will cause freeze burns to the skin
Do not allow children to tamper or play with
cylinder.
When not connected for use, keep cylinder valve
turned off. Self contained appliances shall be
limited to a cylinder of 30l lb. capacity or less.
Do not use, store or transport cylinder where it
would be exposed to high temperatures. Relief
valve may open allowing a large amount of
flammable gas to escape.
When transporting, keep cylinder secured in an
upright position with cylinder valve turned off.
Do not check for gas leaks with a match or an open
flame. Apply soapy water to areas marked "X".
Open cylinder valve. If bubble appears, close valve
and have LP-gas service person make needed
repairs. Also check appliance valves and
connections to make sure they do not leak before
lighting appliance,
Light appliance(s) following manufacturer's
instructions.
When appliance is not in use, keep the cylinder
valve closed.
DO NOT REMOVE, DEFACE, OR OBLITERATE THIS LABEL
*EXCEPT AS AUTHORIZED BY ANSI/NFPA 58.
DANGER! Do not store a spare LP cylinder under or near a barbeque, or other heat sources.
Never fill an LP cylinder beyond 80% full: a fire causing death or serious injury may occur.
Page 06
LAVA GRANULES MEDIA PLACEMENT
p
A.
Carefully inspect the carton for shipping damage. If any parts are missing or damaged, call your dealer.
Do not attem
B.Correct installation is crucial to safe performance of your Outdoor Fire Pit.
Due to high temperatures, the Fire Pit must be located out of traffic areas and away from combustibles.
C.
t to install the appliance unless all parts are in good condition.
LAVA GRANULES AND GLASS MEDIA PLACEMENT
REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER
#1 Stainless Steel T-Burner
#2 Propane Regulator
#3 On/Off Control Knob
#4 Brass Replacement Valve
#5 Whisper Quiet Flex Line 22"
#6 Brass Fitting
#7 Orifice Propane
#8 Propane to Natural Gas Conversion Kit
#9 Lava Granules 3/8"