A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT
FOR PROPANE AND *NATURAL GAS
CODE AND SUPPLY REQUIREMENTS: When an appliance is for connection to a fixed piping system, the installation
must conform with local codes, or in the absence of local codes with the National Fuel Gas Code ANSI Z223.1/NFPA 54,
OR International Fuel Gas Code.
!
WARNING: FOR OUTDOOR USE ONLY
®
OWNER’S MANUAL
Tested & Certified to
ANSI Z21.97-2010
CGA 2.17-M91 (R2009)
™
*
!
WARNING
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
An LP-cylinder not connected for use shall not be
stored in the vicinity of this or any other appliance.
!
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and
immediately call your gas supplier or fire department.
DANGER
This appliance can produce carbon monoxide
CARBON MONOXIDE HAZARD
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space
such as a cam
tent, car, or home.
!
WARNING
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage. Read the installation,
operating and maintenance
instructions thoroughly before
installing or servicing this
equipment.
This appliance is designed as an
“attended appliance”. Adults must
be present when the unit is
operating. DO NOT leave this unit
burning when unattended. If this
product is left burning unattended
it may cause damage or serious
injury.
INSTALLER - Owner’s Manual must be left with the
consumer for future reference.
CONSUMER – Owner’s Manual must be saved for
future reference.
1
O.W. LEE OUTDOOR FIRE PIT
–
TABLE OF CONTENTS
Cover – Important Safety Information.……………………….………………………………………………… 1
Table of Contents…….……………………………………….………………………………………………….. 2
Important Safety Information
Minimum Clearances to Combustibles…………….………………………………………………… 2
Pre-Installation & Preparation Guidelines………….………………………………………………... 3
Installation Information
Connecting the Gas to the Fire Pit…..………...……………………………………………………… 5
Parts List..………….…………………………..……..…………………………………………………. 6
Conversion for Hig h Altitude or Conversion to a Different Gas Type…………………………………….. 8
IMPORTANT SAFETY INFORMATION
READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT
If not installed and used correctly per these instructions, this product can cause serious injury.
CAUTION: INSTALLATION, MODIFICATION AND REPAIR MUST BE DONE BY
A QUALIFIED, PROFESSIONAL INSTALLER.
Be sure you understand all safety precautions and warnings contained in this manual.
A. CHECK STATE AND LOCAL CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS
PERMITTED IN YOUR LOCALITY BEFORE INSTALLATION.
B. FOR OUTDOOR USE ONLY. THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM
CENTER OF BURNER TO ANY COMBUSTIBLE WALLS OR MATERIAL.
IT MUST NOT BE INSTALLED UNDER ANY TYPE OF CEILING OR OVERHANG.
C. When shutting the unit down—be sure to TURN THE CONTROL VALVE FULLY OFF.
D. WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. DO NOT
MODIFY THIS OUTDOOR FIRE PIT OR ITS CONTROLS, EXCEPT AS PROVIDED FOR
IN THIS MANUAL.
Any other change may be dangerous. Improper installation or use of your Outdoor Fire Pit
can cause serious injury or death from fire, burns, explosions or carbon monoxide
poisoning.
MINIMUM CLEARANCE TO COMBUSTIBLES
NOTE
NOTHING SHOULD BE ABOVE THE
OUTDOOR FIRE PIT
60” (1.5 m)
CLEARANCE
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION
60” (1.5 m)
CLEARANCE
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION
Clearances to Combustible Construction:
Sidewalls: 60” (1.5 m) from center of unit (Figure 1)
Ceiling: Nothing should be above the
Outdoor Fire Pit
Flooring: 0” – Can be installed on deck, slab,
floor, etc.
The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maintain when you install this
Outdoor Fire Pit. THERE MUST BE AT LEAST 60” of clearance from the center of the unit to any
combustible sidewalls. The unit MUST NOT BE
installed under any type of ceiling or overhang.
2
IMPORTANT SAFETY INFORMATION
PRE-INSTALLATION AND PREPARATION SAFETY GUIDELINES
A. Before installing this Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2. MINIMUM
CLEARANCES must be maintained when you install this Outdoor Fire Pit. THERE MUST BE AT LEAST 60”
(1.5 m) from the center of the burner to any combustible sidewall. The unit MUST NOT BE installed under any
type of ceiling or overhang.
B. The Outdoor Fire Pit is for outdoor use only. DO NOT install or use this appliance inside a building, garage, or
any other enclosed area including recreational vehicles and/or boats. This unit must be installed in such a
manner that proper air ventilation is maintained without obstruction at all times, and during all weather
conditions.
C. CHECK GAS TYPE (natural gas or propane): The gas supply you intend to use may not be the same as that
stated on your outdoor rating plate. THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS. If the
gas supply is different, or or you wish to change to natural gas, you MUST have the Fire Pit converted (method described on page 8) to the gas type you intend to use, by a qualified, professional installer. If
you are unsure, contact your dealer for assistance.
D. DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE
MAXIMUM.
E. FOR NATURAL GAS: The minimum inlet gas supply pressure for purposes of input adjustment is 5 inches (127
mm) water column and maximum inlet gas supply pressure is 10 inches (254 mm) water column.
FOR PROPANE: The minimum inlet gas supply pressure for purposes of input adjustment is 8 inches (203 mm)
water column and the maximum inlet gas supply pressure is 13 inches (330 mm) water colum n.
DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS
EXCEEDED.
F. Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr). Undue
pressure loss will occur if the pipe is too small or the run is too long.
G. For installations at elevations above 2,000 ft., contact your local dealer or gas supplier before installing as input
ratings will be reduced approximately 4% for each 1,000 ft. above sea level. Refer to the National Fuel Gas
Code.
H. If the Outdoor Fire Pit is connected to Natural Gas, its main gas valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5kPa).
Contact the dealer for the required orifice (Also see page 8 of instructions).
I. If the Outdoor Fire Pit is connected to Natural Gas, it must be isolated from the gas supply piping system by
closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5kPa).
J. INSTALLER NOTE: This unit should be installed so that it can be removed at a later date for service.
K. GAS SUPPLY PLUMBING REQUIREMENTS
Apply only joint compounds that are resistant to all gasses on all male pipe fittings. Make sure to tighten every
joint securely. Do not use pipe joint compound to connect flare fittings.
SAFETY NOTE: An external on/off valve in the gas line is required for safety when your Outdoor Fire Pit is
not in use. It also provides for convenient maintenance and repair.