![](/html/c1/c1ce/c1ceb77164e395b3a83c0d42ec44563f6f53f022b4e28f91ed71013d2b6a7dfb/bg1.png)
CAUTION:
Equipment Damage
See the SmartRE Installation
Manual for detailed information
on installing the battery cables,
including torque requirements.
Use a DC voltmeter to ensure
correct voltage and polarity.
Ensure the cables
are placed in the correct order
with other hardware.
Failure to do so can damage
the equipment and may not be
covered under warranty.
Electronics Enclosure
(Factory wiring not shown)
BAT (–)
2a
10
INVERTER
GRID
GEN
AC IN
AC IN
AC
INVERTER
LOAD #1ACLOAD #2
AC OUT
BYPASS
Battery Enclosure Cabling Kit – SRC-BC3
For a 48-volt Battery Bank
Intended for use as a universal connection kit for eight 6-volt batteries, wired in “series”, using
two (2) SmartRE Battery Enclosures. The Electronics Enclosure must be stacked on top of the
primary battery enclosure (as shown). Includes the following cables:
20"
3/8" Lug 3/8" Lug
BAT (+)
7a
GROUND
CHARGE
SOLAR
DC
FAULT
CONTROL
LOAD
INVERTER
INPUT
CHARGER
WARNING:
Shock Hazard
Ensure the Inverter Charger
Breaker is in OFF position
BEFORE making connections.
Battery Enclosures (x2)
(Batteries shown wired in “Series/Parallel”)
3/8" Lug
3/8" Lug
3/8" Lug
3/8" Lug
3/8" Lug
1
30"
2
2a 2b
3
4
5
6
20” Black #1/0 AWG (x1)
with 3/8" lugs on both ends
3/8" Lug
3/8" Lug
3/8" Lug
3/8" Lug
3/8" Lug
30” Black #1/0 AWG (x5)
with 3/8" lugs on both ends
NOTE:
1. All cable lengths measure “eye-to-eye.
Eye-to-Eye
2. No hardware for securing the cable
to the battery is provided with this
kit. Hardware (nuts, bolts, and washers)
for securing the cable to the battery
should comply with the specifications
from the battery manufacturer.
Connecting Cables:
Connecting Cables:
1. Connect .
2. Connect and .
3. Do NOT connect
or yet.
2b
4. Connect .
5. Connect .
6. Connect .
7. Then connect .
8. Then connect .
10 11
7a
1 3 4
8 9
5 6
7b
2b
2a
7b
2b
6Vdc
10
5
30” Red #1/0 AWG (x1)
with one 5/16” lug* and one 3/8” lug
*attaches to DC Breaker
11
5/16" Lug
7a
7
7b
3/8" Lug
7
65"
7b
6 Vdc
6Vdc
1
6Vdc
3
6
4
3/8" Lug
3/8" Lug
OFF
DC Breaker
8
9
with 5/16" lug
Hardware Order on
7a
the DC Breaker:
Flat
Washer
BAT (+)
Locking
Washer
Nut
3/8" Lug
3/8" Lug
65” Black #1/0 AWG (x2) with 3/8" lugs on both ends
Hardware Order
2a
on the Shunt:
Bolt
Lock
Washer
Flat Washer
BAT (–)
from CC
SHUNT
BAT (–)
with 3/8" lug
IMPORTANT: All configurations
must comply with local and national
electric codes. Consult your local
electric authority to ensure compliance.
Actual wiring requirements may
vary. Factory wiring is not shown.
900-0105-01-00 Rev A
© March 2010 OutBack Power Systems. All Rights Reserved.
6Vdc
9
6Vdc
8
6Vdc
8
6Vdc
IMPORTANT: Grounding
Battery Negative (–) to Chassis Ground Bond is done through the GFDI.
10
#6 AWG THHN recommended
#6 AWG THHN recommended
9
11
Proper cabinet grounding may still be required. Ground conductors are not
provided with this kit. Consult local electric code to ensure compliance.
This is intended for a Negative Ground installation. Do not use in a Positive
Ground installation.
Main Office
19009 62nd Avenue NE
Arlington, WA USA
1.360.435.6030