Outback HUB 10.3 Quick Start Manual

#10 x ½” Screws x 2
Quick Start Guide
900-0154-01-00 Rev A.vsd\2013-03-13 ©2013 OutBack Power Technologies. All Rights Reserved.
HUB 10.3
HUB10.3 HUB Wiring Cover
Cable, CAT5e, 3' (1 m) x 2 Cable, CAT5e, 6' (2 m) x 3
Parts List
Contact Technical Support:
Telephone: +1.360.618.4363 Email: Support@outbackpower.com Website: www.outbackpower.com
IMPORTANT:
Not intended for use with
life support equipment.
OutBack Power, the OutBack Power Logo, and FLEXgrid are trademarks owned and used by OutBack Power Technologies, Inc. The ALPHA logo and the phrase “member of the Alpha Group” are trademarks owned and used by Alpha Technologies. These trademarks may be registered in the United States and other countries.
Stacking
HUB 10.3
900-0154-01-00 Rev A.vsd\2013-03-13 ©2013 OutBack Power Technologies. All Rights Reserved.
Jumper position identified by MATE3 on power-up:
3-Phase/Split
Single-Phase
3.
Changing Jumpers
1. 2.
Used for classic series, OutBack series, and parallel stacking. This is the factory-installed initial position.
Used for Subphase Master stacking (both three-phase and series configurations).
4a.
Single-phase (all jumpers)
4b.
3-Phase/Split (all jumpers)
3.
2.
1.
1" recommended
Mounting
NOTE: This option requires MATE3
firmware revision 002.013.000 or higher.
Master A
Master C
Slave
Slave
Slave
Slave
or
X
1stMATE
1
2 3
4
5 6
7
8 9
10
Three-Phase Stack (Subphase Master)
Up to 9 inverters (ports 1 to 9); 1 other device (port 10); MATE3 only Ports 1, 4, and 7 are required regardless of the number of slaves; also, the number of slaves should be even
Jumpers must be in
“3-Phase/Split” position
Rev 002.013.000
or higher
Port 1
Stack Mode Master
Port 2
Stack Mode Slave
or OB Slave L1
Port 4
Stack Mode B Phase Master
or 3p Classic B
Port 7
Stack Mode C Phase Master
or 3p Classic C
Also ports 3, 5, 6, 8, and 9
1
st
MATE
X
or
Port 1
Stack Mode Master
Port 2
Stack Mode 3phase OB Slave A
3phase OB Slave B 3phase OB Slave C
Three-Phase Stack
Up to 9 inverters; 1 other device (MATE or MATE3)
10987654321
Models
Ports 2 to 10 can be assigned any
3phase OB Slave stack mode;
no more than 3 inverters per mode
Jumpers must be in
“Single-phase” position
GTFX (E Series) GVFX (E Series)
A
C
B
Master B
Slave
Slave
Back of HUB 10.3
10.63" (27 cm)
6.18"
(15.7 cm)
1.27" (3.2 cm)
4.23"
(10.7 cm)
9.24" (23.5 cm)
Dimensions
GS7048E GFX GFX (E Series)
Models
A
C
B
Single-phase inverters:
Three-phase output
PHASE A PHASE B PHASE C
Shutter Bushing x 2 Snap Bushing x 2
or
Single-phase inverters:
Three-phase output
Stacking
HUB 10.3
Stacking
10987654321
X
1
st
MATE
FX / VFX (includes J, M, N Series)
Models
Port 1
Stack Mode Master or 1-2phase Master
Port 2
Stack Mode OB Slave L1
or OB Slave L2
Series Stack (OutBack)
Up to 10 inverters or other devices (MATE or MATE3) Requires balancing transformer
HUB 10.3
Jumpers must be in
“Single-phase” position
900-0154-01-00 Rev A.vsd\2013-03-13 ©2013 OutBack Power Technologies. All Rights Reserved.
900-0154-01-00 Rev A.vsd\2013-03-13 ©2013 OutBack Power Technologies. All Rights Reserved.
10987654321
X
1
st
MATE
FX / VFX (includes J, M, N Series)
GTFX GVFX GTFX (LA Series) GVFX (LA Series)
Models
Port 1
Stack Mode Master or 1-2phase Master
Port 2
Stack Mode Classic Slave
Series Stack (Classic)
2 inverters; up to 8 other devices (MATE or MATE3)
GFX
Jumpers must be in
“Single-phase” position
10 987 654 321
X
1
st
MATE
GFX
Models
Series Stack (Subphase Master)
Up to 8 inverters (ports 1 to 4, 7 to 10); 2 other devices (ports 5, 6); MATE or MATE3 No balancing transformer required Improves control of individual phase voltages and outputs Ports 2 to 4 are L1 slaves; ports 8 to 10 are L2 slaves despite the screen selection (OB Slave L1); equal inverters should be on L1 and L2 Port 7 is the L2 subphase master despite the screen selection (Classic Slave); this port is required regardless of number of slaves
Jumpers must be in
“3-Phase/Split” position
Port 1
Stack Mode Master
Port 2
Stack Mode OB Slave L1
Also ports 3, 4, 8, 9, and 10
Port 7
Stack Mode Classic Slave
1
st
MATE
X
or
Port 1
Stack Mode Master or 1-2phase Master
Port 2
Stack Mode Slave or OB Slave L1
Parallel Stack
Up to 10 inverters or other devices (MATE or MATE3 where appropriate)
10987654321
GS8048
Models
FX / VFX (all series, including E, J, M, N, and W)
Also port 3, etc.
Jumpers must be in
“Single-phase” position
GS7048E GFX GFX (E Series)
(with FX-class inverter)
or
or
Single-phase inverters:
Single-phase output
Split-phase inverters:
Split-phase output
GTFX (E Series) GVFX (E Series)
Single-phase inverters:
Split-phase output
Single-phase inverters:
Split-phase output
Ports 2 to 10 can be assigned to either
OB Slave L1 or OB Slave L2;
equal numbers of inverters should be
assigned to each side
or
Single-phase inverters:
Split-phase output