Ouellet RC840 User Manual

RC840T - Installation Instructions

On/Off Switching Electric Heating Relay with Built-in 24 V Transformer
RC840T

Application

The RC840T Electric Heating Relay is designed to control a line voltage resistive load from a low voltage thermostat. The RC840T relay has a built-in 24 V transformer and is compatible with 3-wire (R,C,W) thermostats as well as 2-wire mechanical and battery­operated thermostats.
NOTE: Not recommended for fast-cycling modulated regulation. For
fast-cycling heating equipment, we recommend the RT850 or RT850T (integrated 24 V transformer) Solid State Relay.

Installation

The RC840T must be installed in an area where the temperature is between -4°F and 140°F (-20°C and 60°C).
The RC840T can be installed on the side of an electrical box (1) or a distribution panel or inside the wiring compartment of an electric baseboard (2).
q Increase the thermostat temperature to activate the relay. Allow
system operation long enough to proof installation. Once installation has been proofed, set temperature to normal setpoint.

Typical Wiring Diagrams

You must provide an overload protection and disconnect as required.
Figure 1: Connection to a 2-wire low voltage thermostat
For proper installation, use a screw and a washer.
Figure 1: Installation on
the side of an electrical box
All wiring must comply with national and local electrical
code regulations.
Installation should be carried out by an electrician. Disconnect power supply before installing the relay to pre-
vent electrical shock.
Figure 2: Installation inside
the wiring compartment of a baseboard
You must provide an overload protection and disconnect as required.
Figure 2: Connection to a 3-wire low voltage thermostat
n Secure relay to the mounting surface using the two mounting
brackets. Use the supplied lock nut to secure the relay to the junction box.
o Wire the relay and connect according to typical wiring diagrams
(refer to figures 1 & 2).
p Once mounting and wiring have been completed, return power
to the heating system and test the installation.
1/2 400-276-002-B

Electrical Specifications

Warranty

Ensure ratings are suitable for your application.
Voltage (VAC) 208 240 277 347
Resistive load (A) 22 22 19 18
Inductive load (HP) 1.0 1.5
FLA 12
LRA 50
Control signal 24 VAC / 40 mA / 1.2 VA
Transformer ratings: 24 VAC / 1.2 VA / Class 2 Ambient operating temperature: -4°F to 140°F (-20°C to 60°C) Ambient storage: -40°F to 175°F (-40°C to 80°C) Humidity limits: 0 to 95% non-condensing Net weight: 11.5 oz. (326 g) Terminal wire size: 12 AWG Certification:
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment.
AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:
Aube Technologies Inc. 705 Montrichard Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8

Technical Support

If you have any questions concerning the installation of the RC840T relay, call our technical support team at:
Phone: Montreal area: (450) 358-4600
Canada / U.S.: 1-800-831-AUBE
Fax: (450) 358-4650 Email: service@aubetech.com
Monday to Friday from 8:30 AM to 5:00 PM EST.
(2823)

RC840T Dimensions

For more information on our products, visit us at:
www.aubetech.com
Dimensions are expressed in INCHES [MM]
2/2 10/07/03 400-276-002-B