3.2STANDALONE UNIT INSTALLATION .............................................................................................................................. 7
(8) WARRANTY INFORMATION ......................................................................................................................... 15
(9) CONTACT INFORMATION ............................................................................................................................. 16
www.ot-systems.com3
FTD110DB-XXR3 Series Installation & Operation Manual
(1) Safety Instructions
Please be familiar with all information in this manual prior to installation and
operation.
Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following
safety precautions apply.
Warning: Do not disconnect the fiber optic connector while the unit is powered up.
Exposure to Class I invisible optical radiation is possible when the internal fiber optic
connector is disconnected while the unit is powered up.
Caution: Any access to the controls, adjustments, or performing operations, which are
other than those specified may result in hazardous radiation exposure. Permanent eye
damage or other bodily injuries may be resulted from such exposure even for only
seconds.
Note 2: This assembly contains parts sensitive to damage by electrostatic discharge (ESD). ESD
precautionary procedures should be applied in the course of touching, removing or inserting parts
or assemblies.
www.ot-systems.com4
FTD110DB-XXR3 Series Installation & Operation Manual
(2) Product Overview
2.1 Introduction
The FTD110DB-XXR3 Series products comprise of either single-mode or multi-mode fiber
optic receivers catering for multi-channel optical transmissions of ONE forward (Tx → Rx) video
and ONE bi-directional (Tx ↔ Rx) data signal on THREE individual fiber links. The products work
at wavelengths of 1310nm and 1550nm with either a 9/125um or 62.5/125um fiber for
single-mode or multi-mode transmission respectively.
The FTD110DB-XXR3 Series products are compatible with the transmitters of the
FTD110DBMicro Series, FTD110DBM Series and FTD110DB Series.
A non-compressed 8-bit digital video transmission scheme is implemented which supports
video in NTSC, PAL and SECAM formats. Transparent data transmission is also accomplished in
RS232, RS422 and RS485 formats regardless of the type of communication protocol
implemented within the system. Time Division Multiplex (TDM) technology is employed for digital
transmission of forward video and data; whereas optical Wavelength Division Multiplex (WDM)
technology is employed for simultaneous reverse data transmission as well as bi-directional data
transmission.
For single-mode transmission, we also offer specifically designed products for long-haul
transmissions up to 60km. These models include the letter “L” in the suffix, e.g.
FTD110DB-SSR3L, etc.
The FTD110DB-XXR3 Series are available as standalone units, which can be mounted
horizontally or vertically wall-mounted on any fixture. The standalone unit comes with an external
power supply FT-PA/12V, which can be powered by local 110/220V power.
The FTD110DB-XXR3 Series are also available as plug-in card modules installed in a 19”
rack-mount chassis. Each plug-in card occupies two slot in the rack-mount chassis. The rack
mount chassis has to be ordered separately, and comes with its own power supply for powering
the installed card modules.
www.ot-systems.com5
FTD110DB-XXR3 Series Installation & Operation Manual
Type
Mode
Models1
Descriptions
Installation
requirements
Remarks
Standalone Units
Single-Mode
FTD110DB-SSR3SA
Triple Independendent Single-mode
Video Receiver & Data Transceiver
Standalone Unit
Horizontally or
vertically
wall-mounted
Standalone
unit
FT-PA/12V
external
power
supply is
included for
the
Standalone
unit
2
FTD110DB-SSR3LSA
Triple Independendent Single-mode
Long-haul Video Receiver & Data
Transceiver Standalone Unit
Multi-Mode
FTD110DB-SMR3SA
Triple Independendent Multi-mode
Video Receiver & Data Transceiver
Standalone Unit
Card Modules
Single-Mode
FTD110DB-SSR3
Triple Independendent Single-mode
Video Receiver & Data Transceiver
Card Module
Housed in
FT-C18
chassis
3
FT-C18
chassis has
to be
ordered
separately
FTD110DB-SSR3L
Triple Independendent Single-mode
Long-haul Video Receiver & Data
Transceiver Card Module
Multi-Mode
FTD110DB-SMR3
Triple Independendent Multi-mode
Video Receiver & Data Transceiver
Card Module
2.2 Models selection table
1
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FTD110DB-FSR3
2
FT-PA/12V works under 100 -240VAC, 50/60Hz power supply
3
Refer to FT-C18 product manual for specifications
www.ot-systems.com6
FTD110DB-XXR3 Series Installation & Operation Manual
Fig. 3.1 Standalone unit
Fig. 3.2 FT-C18 chassis
(3) Installation
3.1 General
All OT Systems products are thoroughly inspected, tested and securely packaged before
delivery to ensure a stable, intact and trouble-free service. Please check the equipment upon
receipt for any visible damage which may have been caused during shipping.
The FTD110DB-XXR3SA Series standalone units (Fig. 3.1) can be either horizontally or
vertically wall-mounted, or mounted on any fixture. The Standalone unit works with an external
power supply FT-PA/12V powered by local 110/220V power.
The FTD110DB-XXR3 Series card modules are housed inside the FT-C18 rack-mount
chassis (Fig. 3.2) with an included power supply unit. The whole chassis is powered by local
110/220V power. FT-C18 is a standard 19” (483mm) rack-mount chassis which occupies 4 rack
units (177.8mm) in height. Each FT110DF card module occupies two slot and a total of 9 cards
can be housed inside the chassis.
3.2 Standalone unit installation
a) Mount the standalone unit onto a fixture, (either on the wall or on a flat surface) with four
screws through the holes on the mounting frame to secure it in position.
b) The provided power supply should also be mounted on the same fixture or in the proximity
for connection of the supply cables to the unit, provided that an AC power supply socket is
nearby for powering the adaptor.
c) Connect all the signal inputs and outputs at the back of the unit with appropriate cables:
fiber optic cable for optical link, BNC cables for video outputs, and UTP cables for data
inputs/outputs.
d) Once the unit is powered up, check that the red POWER LED on the unit is lit. If not, check
the power supply cable connections between the unit and the power supply socket.
e) With all the signals available at the input and output ports, check the status of LEDs located
on the unit. With correct status of each LED, installation is now completed [for LEDs status, see
Operational Guideson this manual’s section (5)].
www.ot-systems.com7
FTD110DB-XXR3 Series Installation & Operation Manual
Signal Type
Cable Type
Connector
Optical
Single-mode or Multi-mode fibers
ST (or FC) Connectors
Video
Coaxial Video Cables
BNC Connectors
Data
Twisted-pair Cables
Screw Terminal Blocks
3.3 Card module installation
a) Insert the card module into the FT-C18 chassis along the top and bottom card guides of an
empty slot and push the card into the multi-pin socket at the rear firmly. Secure with the provided
thumb screws.
b) Repeat the above procedure for all the rest card modules. Unused slots must be covered
with blank panels provided.
c) Connect all the signal inputs and outputs at the back of the unit with appropriate cables:
fiber optic cable for optical link, BNC cables for video outputs, and UTP cables for data
inputs/outputs.
d) Once the chassis is powered up, check that the red POWER LED on the front and back
panels of the card modules are lit. If not, check the power supply cable connections between the
chassis and the power supply socket. For failures of individual card’s POWER LEDs, check the
corresponding card modules, whether they have been inserted properly.
e) With all the signals available at the input and output ports, check the status of LEDs located
on the unit. With correct status of each LED, installation is now completed [for LEDs status, see
Operational Guides on this manual’s section (5)].
(4) Cable Connections & Setup Procedures
4.1 System cable connections
www.ot-systems.com8
FTD110DB-XXR3 Series Installation & Operation Manual
TRANSMITTERS CAN BE:
FTD110DBMicro Series
FTD110DBM Series
FTD110DB Series
TRANSMITTERS CAN BE:
FTD110DBMicro Series
FTD110DBM Series
FTD110DB Series
Typical System Cable Connections Diagrams:
FTD110DB-XXR3 Series Receiver
Fig 4.1 Micro units to Card Module connection diagram
www.ot-systems.com9
FTD110DB-XXR3SA Series Receiver
Fig 4.2 Micro units to Standalone unit connection diagram
FTD110DB-XXR3 Series Installation & Operation Manual
Pin Assignment
(Screw Terminal
Block)
Data format
1 2 3 4 5 6 7
RS422/485 (4-Wire)
IN(+)
IN(-)
OUT(+)
OUT(-)
N/A
N/A
N/A
RS485 (2-Wire)
IN/OUT (+)
IN/OUT (-)
N/A
N/A
N/A
N/A
N/A
RS232
N/A
N/A
N/A
N/A
IN
OUT
Sig. COM
User’s Equipment
DATA PORT
(7-PIN)
DATA PORT
(7-PIN)
User’s Equipment
TX(+)
1 IN(+)
1 IN(+)
TX(+)
TX(-)
2 IN(-)
2 IN(-)
TX(-)
RX(+)
3 OUT(+)
3 OUT(+)
RX(+)
RX(-)
4 OUT(-)
4 OUT(-)
RX(-)
5 N/A
5 N/A
6 N/A
6 N/A
7 N/A
7 N/A
User’s Equipment
DATA PORT
(7-PIN)
DATA PORT
(7-PIN)
User’s Equipment
TX/RX(+)
1 IN/OUT(+)
1 IN/OUT(+)
TX/RX(+)
TX/RX(-)
2 IN/OUT(-)
2 IN/OUT(-)
TX/RX(-)
3 N/A
3 N/A
4 N/A
4 N/A
5 N/A
5 N/A
6 N/A
6 N/A
7 N/A
7 N/A
4.2 Data port assignment and pin connections
Data ports assignments and pin connections are identical for Data1,Data2 and Data3.
For data input and output connections, please note the following pin assignment:
4-Wire RS422/485 Full Duplex Data communication connection diagram:
Transmitter End Receiver End
Fig. 4.3.1 Connector Pin Assignments for 4-wire RS422/485 data format at Data port
2-Wire RS485 Half Duplex Data communication connection diagram:
Transmitter End Receiver End
Fig. 4.3.2 Connector Pin Assignments for 2-wire RS485 data format at Data port.
www.ot-systems.com10
FTD110DB-XXR3 Series Installation & Operation Manual
User’s Equipment
DATA PORT
(7-PIN)
DATA PORT
(7-PIN)
User’s Equipment
1 N/A
1 N/A
2 N/A
2 N/A
3 N/A
3 N/A
4 N/A
4 N/A
TX 5 IN
5 IN
TX
RX 6 OUT
6 OUT
RX
Sig. COM
7 Sig. COM
7 Sig. COM
Sig. COM
(a) Dip switches on FTD110DB-XXR3 Series Standalone unit
RS232 Data communication connection diagram:
Transmitter End Receiver End
Fig. 4.3.3 Connector Pin Assignments for RS232 data format at Data port
4.3 Dip switch setting procedures
The only setup procedure is to select the appropriate line terminations and data
transmission formats. Selections must be made by setting the dip switches (Fig. 4.8) through the
access on the front panel.
Fig. 4.4 Location of Dip Switches
www.ot-systems.com11
(b) Dip switches on FTD110DB-XXR3 Series Card Module
FTD110DB-XXR3 Series Installation & Operation Manual
Function / Switch No.
Sw. 3
Sw. 4
RS485 (2-Wire)
OFF
OFF
RS422/485 (4-Wire)*
OFF
ON
RS232
ON
OFF
Function / Switch No.
Sw. 1
Line Output Terminated
ON
Line Output Unterminated*
OFF Function / Switch No.
Sw. 2
Line Input Terminated
ON
Line Input Unterminated*
OFF
Dip switch settings for various types of data transmissions
* Factory setting [RS422/485 (4-Wire)]
Dip switch settings for line terminations
Line Output Termination Line Input Termination
* Factory setting (Line Output and Line Input “Unterminated”)
Industrial practice for line terminations
For RS422 4-wire communication, it is suggested to keep the input and output lines
terminated in the ONE Tx to ONE Rx configuration.
For RS485 2/4-wire communication, the RS485 device can be disabled to stay in a Hi-Z
state. It is very important that the data lines have to be terminated with a resistor being
connected across the pair wires so as to eliminate the residual standing signal waves on the
lines in the Hi-Z line condition. So, it is recommended that the lines should be terminated with the
appropriate resistance. When more than one RS485 device are connected in a daisy-chain
configuration, only the farthest device on the loop, i.e. the device located at the end of the line,
should be terminated; whereas the middles ones are set to “Unterminated” status. See the figure
4.6 below for reference.
(a) RS485/422 4-wires Bus structure (b) RS485 2-wire Bus structure
www.ot-systems.com12
Fig. 4.5 Termination of different Bus structures
FTD110DB-XXR3 Series Installation & Operation Manual
Indicator
Color
Description
CH1
CH2
CH3
PWR
Red
Lit when power is supplied to the Receiver.
OL
Yellow
Lit when optical signal from transmitter to receiver is active.
V1, V2 or V3
Green
Lit when video signals are available at the VIDEO OUT connectors.
DATA
IN
Red
Blinks when input data is available at Rx.
OUT
Green
Blinks when output data is available at Rx.
CH1
OPT 1-
ST (or FC) Optical Connector for fiber cable connection.
VIDEO OUT 1-
BNC Video Connector for video signal ouput.
DATA 1-
7-pin Screw Terminal Block for data signal.
CH2
OPT 2-
ST (or FC) Optical Connector for fiber cable connection.
VIDEO OUT 2-
BNC Video Connector for video signal ouput.
DATA 2-
7-pin Screw Terminal Block for data signal.
CH3
OPT 3-
ST (or FC) Optical Connector for fiber cable connection.
VIDEO OUT 3-
BNC Video Connector for video signal ouput.
DATA 3-
7-pin Screw Terminal Block for data signal.
4.4 Ground connection
For enhanced safety to reduce the risks of electrical shock and physical damage, caused by
lightning and other power surges, as well as a connection to the surge suppresion devices in the
product, a screw terminal is provided on the Standalone cabinets (Fig. 4.7). It is highly
recommended that the Standalone unit have good ground connections to the buildings ground in
accordance with the local codes.
Fig. 4.6 Standalone unit earth ground terminal location
(5) Operational Guides
LED Indicators
Signal Ports
www.ot-systems.com13
FTD110DB-XXR3 Series Installation & Operation Manual
MODELS*
PARAMETERS
FTD110DB-SSR3SA
FTD110DB-SSR3
(Single-Mode)
FTD110DB-SSR3LSA
FTD110DB-SSR3L
(Single-Mode)
FTD110DB-SMR3SA
FTD110DB-SMR3
(Multi-Mode)
OPTICAL
No. of Fiber / Connector
3 / ST(or FC)
3 / ST(or FC)
3 / ST(or FC)
Wavelength
1310/1550 nm
1550/1310 nm
1310/1550 nm
Optical Power Budget
17 dB
24 dB
23 dB
Max Distance
40 km
60 km
4 km
ELECTRICAL VIDEO
Channel / Connector
3 / BNC
System
PAL, NTSC, SECAM
Bandwidth
≥ 6.0 MHz
Input/Output Impedance
75 Ohm
Input/Output Level
1.0 Vp-p typical
Differential Gain
< 1% typical
Differential Phase
< 1o typical
SNR
>60dB
DATA
Channel / Connector
3 / 7-pin Screw Terminal
Direction
Bi-directional (Duplex)
Electrical Format
RS232, RS422, RS485 (2-wire, 4-wire)
Transmission Rate
0~256 Kbps
POWER
Power consumption
12VDC @ 8.4W
Power Supply
Standalone unit: FT/PA12V DC Adaptor
Card module: Powered by FT-C18 chassis
Connector (Micro unit)
2-pin Screw Terminal
PHYSICAL
Weight
Standalone unit: 0.9 kg Card module: 0.4 kg
Dimensions (W x H x D)
Standalone unit: 156 x 50.5 x 223 mm (MAX)
Card module: 148 x 41 x 213 mm (MAX)
ENVIRONMENTAL
Operating Temperature
-40oC ~ +75oC
Storage Temperature
-40oC ~ +85oC
Relative Humidity
0 ~ 95% non-condensing
MTBF
>100’000 Hours
*If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FTD110DBMicro-FST
(6) Specifications
www.ot-systems.com14
FTD110DB-XXR3 Series Installation & Operation Manual
(7) Drawings
Fig. 7.1 Dimensional drawings of Standalone unit (mm)
(8) Warranty Information
All OT Systems FT Series products are subject to a limited life-time warranty offered by the
company in normal circumstances. Please refer to the OT Systems Products Warranty
Statement for details. Access to the statement is available in our company website at
www .ot-systems.com.
www.ot-systems.com15
FTD110DB-XXR3 Series Installation & Operation Manual
(9) Contact Information
APAC Operation
Address:
Unit 1023, 10/F, Landmark
North, 39 Lung Sum Avenue,
Sheung Shui, N.T., Hong Kong
Tel: (852) 2672 5153
Fax: (852) 2679 0756
Sales Inquiries
sales@ot-systems.com
Technical Support
techsupport@ot-systems.com
EMEA Operation
Address:
J. Slovackio str. 4, LT-11107,
Vilnius, Lithuania