OT Systems FT210CB-SSRSA, FT210CB-SSTSA, FT210CB-SSRLSA, FT210CB-SMTSA, FT210CB-SST Installation And Operation Manual

...
Page 1
All Digital Fiber Optic Manufacturing Specialists
Installation and Operation Manual
FT210CB Series
10-bit Digital Series
2-ch Video with 1 Bi-directional Contact Closure
Fiber Optic Converter
OT Systems Ltd., 2009
Rev 1.1
Page 2
FT210CB Series Installation & Operation Manual
www.ot-systems.com 1
Models covered in this manual
Standalone Units
Single-Mode Transmitters FT210CB-SSTSA FT210CB-SSTLSA
Single-Mode Receivers FT210CB-SSRSA FT210CB-SSRLSA
Multi-Mode Transmitter FT210CB-SMTSA
Multi-Mode Receiver FT210CB-SMRSA
Card Modules
Single-Mode Transmitters FT210CB-SST FT210CB-SSTL
Single-Mode Receivers FT210CB-SSR FT210CB-SSRL
Multi-Mode Transmitter FT210CB-SMT
Multi-Mode Receiver FT210CB-SMR
Remark:
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT210CB-FST
Page 3
FT210CB Series Installation & Operation Manual
www.ot-systems.com 2
Table of Contents
(1) SAFETY INSTRUCTIONS ............................................................................. 3
(2) PRODUCT OVERVIEW ................................................................................ 4
2.1 Introduction.................................................................................................... 4
2.2 Models selection table ................................................................................... 5
(3) INSTALLATION ............................................................................................. 6
3.1 General ......................................................................................................... 6
3.2 Standalone unit installation ............................................................................ 6
3.3 Card module installation ................................................................................ 7
(4) CABLE CONNECTIONS & SETUP PROCEDURES ..................................... 7
4.1 System cable connections ............................................................................. 7
4.2 Contact Closure (CC) connections ................................................................ 9
4.3 Ground connection ...................................................................................... 10
(5) OPERATIONAL GUIDES............................................................................. 11
5.1 FT210CB Series Transmitter ....................................................................... 11
5.2 FT210CB Series Receiver ........................................................................... 11
(6) SPECIFICATIONS ....................................................................................... 12
(7) DRAWINGS ................................................................................................. 13
(8) WARRANTY INFORMATION ...................................................................... 13
(9) CONTACT INFORMATION.......................................................................... 13
Page 4
FT210CB Series Installation & Operation Manual
www.ot-systems.com 3
(1) Safety Instructions
Please be familiar with all information in this manual prior to installation and operation.
Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following
safety precautions apply.
Warning: Do not disconnect the fiber optic connector while the unit is powered up. Exposure to Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up.
Caution: Any access to the controls, adjustments, or performing operations, which are other than those specified may result in hazardous radiation exposure. Permanent eye damage or other bodily injuries may be resulted from such exposure even for only seconds.
Note 2: This assembly contains parts sensitive to damage by electrostatic discharge (ESD). ESD precautionary procedures should be applied in the course of touching, removing or inserting parts or assemblies.
Page 5
FT210CB Series Installation & Operation Manual
www.ot-systems.com 4
(2) Product Overview
2.1 Introduction
The FT210CB Series products comprise of either single-mode or multi-mode fiber optic transmitters and receivers for the optical transmission of TWO forward (Tx → Rx) video and ONE bi-directional (Tx ↔ Rx) contact closure signal on one fiber. The products work at wavelengths of 1310nm and 1550nm with either a 9/125um or 62.5/125um fiber for single-mode or multi-mode transmission respectively.
A non-compressed 10-bit digital video transmission scheme is implemented which supports video in NTSC, PAL and SECAM formats.
Bi-directional transmission of Contact Closure (CC) status is also supported. The CC input can be a Dry contact or a TTL logic input. Normally Open (NO) or Normally Close (NC) Contact selectable output is provided for a maximum current of 1000mA at 110VDC/125VAC.
For single-mode transmission, we also offer specifically designed products for long-haul transmissions up to 60km. These models include the letter “L” in the suffix, e.g. FT210CB-SSTL for Tx, FT210CB-SSRL for Rx, etc.
The FT210CB Series units are available as standalone units, which can be mounted horizontally or vertically wall-mounted on any fixture. The standalone unit comes with an external power supply FT-PA/12V, which can be powered by local 110/220V power.
The FT210CB Series units are also available as plug-in card modules installed in a 19” rack-mount chassis. Each plug-in card occupies one slot in the rack-mount chassis. The rack mount chassis has to be ordered separately, and comes with its own power supply for powering the installed card modules.
Page 6
FT210CB Series Installation & Operation Manual
www.ot-systems.com 5
2.2 Models selection table
Type
Mode
Models1
Descriptions
Installation
requirements
Remarks
Standalone Units
SIngle-Mode
FT210CB-SSTSA
Single-mode 2-Ch. Video Transmitter & 1 CC Transceiver Standalone Unit
Horizontally or vertically wall-mounted Standalone unit
FT-PA/12V external power supply is included for the Standalone unit
2
FT210CB-SSTLSA
Single-mode Long-haul 2-Ch. Video Transmitter & 1 CC Transceiver Standalone Unit
FT210CB-SSRSA
Single-mode 2-Ch. Video Receiver & 1 CC Transceiver Standalone Unit
FT210CB-SSRLSA
Single-mode Long-haul 2-Ch. Video Receiver & 1 CC Transceiver Standalone Unit
Multi-Mode
FT210CB-SMTSA
Multi-mode 2-Ch. Video Transmitter & 1 CC Transceiver Standalone Unit
FT210CB-SMRSA
Multi-mode 2-Ch. Video Receiver & 1 CC Transceiver Standalone Unit
Card Modules
Single-Mode
FT210CB-SST
Single-mode 2-Ch. Video Transmitter & 1 CC Transceiver Card Module
Housed in FT-C18 chassis
3
FT-C18 chassis has to be ordered separately
FT210CB-SSTL
Single-mode Long-haul 2-Ch. Video Transmitter & 1 CC Transceiver Card Module
FT210CB-SSR
Single-mode 2-Ch. Video Receiver & 1 CC Transceiver Card Module
FT210CB-SSRL
Single-mode Long-haul 2-Ch. Video Receiver & 1 CC Transceiver Card Module
Multi-Mode
FT210CB-SMT
Multi-mode 2-Ch. Video Transmitter & 1 CC Transceiver Card Module
FT210CB-SMR
Multi-mode 2-Ch. Video Receiver & 1 CC Transceiver Card Module
1
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT210CB-FST
2
FT-PA/12V works under 100 -240VAC, 50/60Hz power supply
3
Refer to FT-C18 product manual for specifications
Page 7
FT210CB Series Installation & Operation Manual
www.ot-systems.com 6
(3) Installation
3.1 General
All OT Systems products are thoroughly inspected, tested and securely packaged before delivery to ensure a stable, intact and trouble-free service. Please check the equipment upon receipt for any visible damage which may have been caused during shipping.
The FT210CB Series standalone units (Fig. 3.1) can be either horizontally or vertically wall-mounted, or mounted on any fixture. The Standalone unit works with an external power supply FT-PA/12V powered by local 110/220V power.
The FT210CB Series card modules are housed inside the FT-C18 rack-mount chassis (Fig.
3.2) with an included power supply unit. The whole chassis is powered by local 110/220V power. FT-C18 is a standard 19” (483mm) rack-mount chassis which occupies 4 rack units (177.8mm) in height. Each FT210CB card module occupies one slot and a total of 18 cards can be housed inside the chassis.
3.2 Standalone unit installation
a) Mount the standalone unit onto a fixture, (either on the wall or on a flat surface) with four screws through the holes on the mounting frame to secure it in position. b) The provided power supply should also be mounted on the same fixture or in the proximity for connection of the supply cables to the unit, provided that an AC power supply socket is nearby for powering the adaptor. c) Connect all the signal inputs and outputs at the back of the unit with appropriate cables: fiber optic cable for optical link, BNC cable for video input/output (Tx/Rx), and UTP cable for contact closure input/output (Tx/Rx). d) Once the unit is powered up, check that the red POWER LED on the unit is lit. If not, check the power supply cable connections between the unit and the power supply socket. e) With all the signals available at the input and output ports, check the status of LEDs located on the unit. With correct status of each LED, installation is now completed [for LEDs status, see Operational Guides on this manual’s section (5)].
Fig. 3.1 Standalone unit
Fig. 3.2 FT-C18 chassis
Page 8
FT210CB Series Installation & Operation Manual
www.ot-systems.com 7
3.3 Card module installation
a) Insert the card module into the FT-C18 chassis along the top and bottom card guides of an empty slot and push the card into the multi-pin socket at the rear firmly. Secure with the provided thumb screws. b) Repeat the above procedure for all the rest card modules. Unused slots must be covered with blank panels provided. c) Connect all the signal inputs and outputs at the back of the unit with appropriate cables: fiber optic cable for optical link, BNC cable for video input/output (Tx/Rx), and UTP cable for contact closure input/output (Tx/Rx). d) Once the chassis is powered up, check that the red POWER LED on the front and back panels of the card modules are lit. If not, check the power supply cable connections between the
chassis and the power supply socket. For failures of individual card’s POWER LEDs, check the
corresponding card modules, whether they have been inserted properly. e) With all the signals available at the input and output ports, check the status of LEDs located on the unit. With correct status of each LED, installation is now completed [for LEDs status, see
Operational Guides on this manual’s section (5)].
(4) Cable Connections & Setup Procedures
4.1 System cable connections
Signal Type
Cable Type
Connector
Optical
Single-mode or Multi-mode fiber
ST (or FC) Connector
Video
Coaxial Video Cable
BNC Connector
Contact closure
Twisted-pair Cable
Screw Terminal Block
Typical System Cable Connections Diagrams:
Standalone Transmitter Standalone Receiver
Fig 4.1 Standalone unit to Standalone unit connection diagram
Page 9
FT210CB Series Installation & Operation Manual
www.ot-systems.com 8
Standalone Transmitter Card Module Receiver
Fig 4.2 Standalone unit to Card Module connection diagram
Card Module Transmitter Card Module Receiver
Fig 4.3 Card Module to Card Module connection diagram
Page 10
FT210CB Series Installation & Operation Manual
www.ot-systems.com 9
4.2 Contact Closure (CC) connections
For Contact closure input and output connections, please note the following pin assignment:
Pin Assignment
(Screw Terminal
Block)
Data format
1 2 3 4 5
6
7
Input
Contact closure / TTL
Input
(Hi)
Input
(Low /COM)
N/A
N/A
N/A
N/A
N/A
Output Normally Close
(NC)
N/A
N/A
Output
(Hi)
Output
(Low /COM)
N/A
N/A
N/A
Normally Open (NO)
N/A
N/A
N/A
Output
(Low /COM)
Output
(Hi)
N/A
N/A
4.2.1 Contact Closure/TTL Input and Normally Close (NC) Output connection diagram:
Transmitter End Receiver End
User’s Equipment
CC (7-PIN)
CC (7-PIN)
User’s Equipment
Hi 1
Contact Input
Contact Input
1 Hi
Low /COM
2 2 Low /COM
Hi 3
Relay Contact Output
Relay Contact Output
3 Hi
Low /COM
4 4 Low /COM
5 5 6 N/A N/A 6 7
N/A N/A 7
Fig. 4.4.1 Connector Pin Assignments for Contact Closure/TTL input and Normally Close (NC)
ouput at CC port
4.2.2 Contact Closure/TTL Input and Normally Open (NO) Output connection diagram:
Transmitter End Receiver End
User’s Equipment
CC (7-PIN)
CC (7-PIN)
User’s Equipment
Hi 1
Contact Input
Contact Input
1 Hi
Low /COM
2 2 Low /COM
3
Relay Contact Output
Relay Contact Output
3
Low /COM
4 4 Low /COM
Hi 5 5 Hi 6 N/A N/A 6 7
N/A N/A 7
Fig. 4.4.2 Connector Pin Assignments for Contact Closure/TTL input and Normally Open (NO)
output at CC port
Page 11
FT210CB Series Installation & Operation Manual
www.ot-systems.com 10
4.3 Ground connection
For enhanced safety to reduce the risks of electrical shock and physical damage, caused by lightning and other power surges, as well as a connection to the surge suppresion devices in the product, a screw terminal is provided on the Standalone cabinets (Fig. 4.5). It is highly recommended that the Standalone unit have good ground connections to the buildings ground in accordance with the local codes.
Fig. 4.5 Standalone unit earth terminal location
Page 12
FT210CB Series Installation & Operation Manual
www.ot-systems.com 11
(5) Operational Guides
5.1 FT210CB Series Transmitter
LED Indicators
Indicator
Color
Description
PWR
Red
Lit when power is supplied to the Transmitter.
OL
Yellow
Lit when optical signal from receiver to transmitter is active.
VIDEO IN /
VIN
V1-V2
Green
Lit when video signals are fed into the VIDEO IN connectors.
CC
IN
Red
Blinks when input CC is available at Tx.
OUT
Green
Blinks when output CC is available at Tx.
Signal Ports
OPT -
ST (or FC) Optical Connector for fiber cable connection.
VIDEO IN -
BNC Video Connector for video signal input.
CC -
7-pin Screw Terminal Block for contact closure signal.
5.2 FT210CB Series Receiver
LED Indicators
Indicator
Color
Description
PWR
Red
Lit when power is supplied to the Receiver.
OL
Yellow
Lit when optical signal from transmitter to receiver is active.
VIDEO OUT /
VOUT
V1-V2
Green
Lit when video signals are received at VIDEO OUT connectors.
CC
IN
Red
Blinks when input CC is available at Rx.
OUT
Green
Blinks when output CC is available at Rx.
Signal Ports
OPT -
ST (or FC) Optical Connector for fiber cable connection.
VIDEO OUT -
BNC Video Connector for video signal output.
CC -
7-pin Screw Terminal Block for contact closure signal.
Page 13
FT210CB Series Installation & Operation Manual
www.ot-systems.com 12
(6) Specifications
MODELS*
PARAMETERS
FT210CB-SST(R)SA FT210CB-SST(R) (Single-Mode)
FT210CB-SST(R)LSA FT210CB-SST(R)L (Single-Mode)
FT210CB-SMT(R)SA FT210CB-SMT(R) (Multi-Mode)
OPTICAL
No. of Fiber / Connector
1 / ST (or FC)
1 / ST (or FC)
1 / ST (or FC)
Wavelength
1310/1550 nm
1550/1310 nm
1310/1550 nm
Optical Power Budget
17 dB
24 dB
23 dB
Max Distance
40 km
60 km
4 km
ELECTRICAL VIDEO
Channel / Connector
2/ BNC
System
PAL, NTSC, SECAM
Bandwidth
6.0 MHz
Input/Output Impedance
75 Ohm
Input/Output Level
1.0 Vp-p typical
Differential Gain
< 1% typical
Differential Phase
< 1o typical
SNR
>65dB
CONTACT CLOSURE
Channel / Connector
1 / 7-pin Screw Terminal
Direction
Bi-directional (Duplex)
Input
Dry contact or TTL input
Output
Dry contact, Normally Open (NO) or Normally Close (NC)
Max. 32VDC/VAC@100mA
POWER
Power consumption
12VDC @ 4.8W
Power Supply
Standalone Unit: FT/PA12V DC Adaptor
Card module: Powered by FT-C18 chassis
Connector (Standalone unit)
2-pin Screw Terminal
PHYSICAL
Weight
Standalone unit: 0.56 kg Card module: 0.2 kg
Dimensions (W x H x D)
Standalone unit: 156 x 30.5 x 223 mm (MAX)
Card module: 148 x 20.4 x 213 mm (MAX)
ENVIRONMENTAL
Operating Temperature
-40oC ~ +75oC
Storage Temperature
-40oC ~ +85oC
Relative Humidity
0 ~ 95% non-condensing
MTBF
>100’000 Hours
*If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT210CB-FST
Page 14
FT210CB Series Installation & Operation Manual
www.ot-systems.com 13
(7) Drawings
Fig. 7.1 Dimensional drawings of Standalone unit (mm)
(8) Warranty Information
All OT Systems products are subject to a limited life-time warranty offered by the company in normal circumstances. Please refer to the OT Systems Products Warranty Statement for details. Access to the statement is available in our company website at www.ot-systems.com.
(9) Contact Information
OT Systems Ltd. (Hong Kong)
Unit 1023, 10/F Landmark North 39 Lung Sum Avenue Sheung Shui, N.T., Hong Kong Tel. +852 2672 5153 Fax. +852 2679 0756
sales@ot-systems.com
OT Systems Ltd. (USA)
River Heights Business Park 5375 US Highway 34 Oswego, IL 60543, USA Tel. +1 630 554 9178 Fax. +1 630 554 9179
sales.usa@ot-systems.com