OT Systems FT040DB User Manual

FT040DB Series Installation & Operation Manual
Installation and Operation Manual
8-bit Digital Series
4-ch Bi-directional Data Fiber Optic Converter
www.ot-systems.com 1
OT Systems Ltd., 2014
Rev 1.2
FT040DB Series Installation & Operation Manual
Standalone Units
Single-Mode Transmitters FT040DB-SSTRSA FT040DB-SSTRLSA
Single-Mode Receivers FT040DB-SSRTSA FT040DB-SSRTLSA
Multi-Mode Transmitter FT040DB-SMTRSA
Multi-Mode Receiver FT040DB-SMRTSA
Card Modules
Single-Mode Transmitters FT040DB-SSTR FT040DB-SSTRL
Single-Mode Receivers FT040DB-SSRT FT040DB-SSRTL
Multi-Mode Transmitter FT040DB-SMTR
Multi-Mode Receiver FT040DB-SMRT
Models covered in this manual
Remark:
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT040DB-FSTR
www.ot-systems.com 2
FT040DB Series Installation & Operation Manual
Table of Contents
(1) SAFETY INSTRUCTIONS .................................................................................................................................. 4
(2) PRODUCT OVERVIEW .................................................................................................................................... 5
2.1 INTRODUCTION ..................................................................................................................................................... 5
2.2 MODELS SELECTION TABLE ...................................................................................................................................... 6
(3) INSTALLATION................................................................................................................................................ 7
3.1 GENERAL ............................................................................................................................................................. 7
3.2 STANDALONE UNIT INSTALLATION .............................................................................................................................. 7
3.3 CARD MODULE INSTALLATION................................................................................................................................... 8
(4) CABLE CONNECTIONS & SETUP PROCEDURES ................................................................................................ 8
4.1 SYSTEM CABLE CONNECTIONS ................................................................................................................................. 8
4.2 DATA, AUDIO & CONTACT CLOSURE PORTS ASSIGNMENTS AND PIN CONNECTIONS............................................................ 10
4.3 DIP SWITCH SETTING PROCEDURES .......................................................................................................................... 11
4.4 GROUND CONNECTION ......................................................................................................................................... 13
(5) OPERATIONAL GUIDES ................................................................................................................................. 14
5.1 FT040DB SERIES TRANSMITTER ............................................................................................................................ 14
5.2 FT040DB SERIES RECEIVER .................................................................................................................................. 14
(6) SPECIFICATIONS ........................................................................................................................................... 15
(7) DRAWINGS .................................................................................................................................................. 16
(8) WARRANTY INFORMATION ......................................................................................................................... 16
(9) CONTACT INFORMATION ............................................................................................................................. 17
www.ot-systems.com 3
FT040DB Series Installation & Operation Manual
(1) Safety Instructions
Please be familiar with all information in this manual prior to installation and operation.
Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following
safety precautions apply.
Warning: Do not disconnect the fiber optic connector while the unit is powered up. Exposure to Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up.
Caution: Any access to the controls, adjustments, or performing operations, which are other than those specified may result in hazardous radiation exposure. Permanent eye damage or other bodily injuries may be resulted from such exposure even for only seconds.
Note 2: This assembly contains parts sensitive to damage by electrostatic discharge (ESD). ESD precautionary procedures should be applied in the course of touching, removing or inserting parts or assemblies.
www.ot-systems.com 4
FT040DB Series Installation & Operation Manual
(2) Product Overview
2.1 Introduction
The FT040DB Series products comprise of either single-mode or multi-mode fiber optic transmitters and receivers for the optical transmission of FOUR bi-directional (Tx ↔ Rx) data signals on one fiber. The products work at wavelengths of 1310nm and 1550nm with either a 9/125um or 62.5/125um fiber for single-mode or multi-mode transmission respectively.
Transparent data transmission is accomplished in RS232, RS422 and RS485 formats regardless of the type of communication protocol implemented within the system. Time Division Multiplex (TDM) technology is employed for digital transmission of forward video and data; whereas optical Wavelength Division Multiplex (WDM) technology is employed for simultaneous reverse data transmission as well as bi-directional data transmission.
For single-mode transmission, we also offer specifically designed products for long-haul transmissions up to 60km. These models include the letter “L” in the suffix, e.g. FT040DB-SSTRL for Tx, FT040DB-SSRTL for Rx, etc.
The FT040DB Series units are available as standalone units, which can be mounted horizontally or vertically wall-mounted on any fixture. The standalone unit comes with an external power supply FT-PA/12V, which can be powered by local 110/220V power.
The FT040DB Series units are also available as plug-in card modules installed in a 19” rack-mount chassis. Each plug-in card occupies one slot in the rack-mount chassis. The rack mount chassis has to be ordered separately, and comes with its own power supply for powering the installed card modules.
www.ot-systems.com 5
FT040DB Series Installation & Operation Manual
Type
Mode
Models1
Descriptions
Installation
requirements
Remarks
Standalone Units
Single-Mode
FT040DB-SSTRSA
Single-mode 4 bi-directional Data Transmitter Standalone unit
Horizontally or vertically wall-mounted Standalone unit
FT-PA/12V external power supply is included for the Standalone unit
2
FT040DB-SSTRLSA
Single-mode Long-haul 4 bi-directional Data Transmitter Standalone unit
FT040DB-SSRTSA
Single-mode 4 bi-directional Data Receiver Standalone unit
FT040DB-SSRTLSA
Single-mode Long-haul 4 bi-directional Data Receiver Standalone unit
Multi-Mode
FT040DB-SMTRSA
Multi-mode 4 bi-directional Data Receiver
Standalone unit
FT040DB-SMRTSA
Multi-mode Long-haul 4 bi-directional Data
Receiver Standalone unit
Card Modules
Single-Mode
FT040DB-SSTR
Single-mode 4 bi-directional Data Transmitter Card Module
Housed in FT-C18 chassis
3
FT-C18 chassis has to be ordered separately
FT040DB-SSTRL
Single-mode Long-haul 4 bi-directional Data Transmitter Card Module
FT040DB-SSRT
Single-mode 4 bi-directional Data Receiver Card Module
FT040DB-SSRTL
Single-mode Long-haul 4 bi-directional Data Receiver Card Module
Multi-Mode
FT040DB-SMTR
Multi-mode 4 bi-directional Data Transmitter Card Module
FT040DB-SMRT
Multi-mode 4 bi-directional Data Receiver Card Module
2.2 Models selection table
1
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT040DB-FSTR
2
FT-PA/12V works under 100 -240VAC, 50/60Hz power supply
3
Refer to FT-C18 product manual for specifications
www.ot-systems.com 6
Loading...