![](/html/24/2421/2421f4c97f253efbd4675517f86be67c0ea988b8f44768fb8692e299c36d5a4f/bg1.png)
FT040DB Series Installation & Operation Manual
Installation and Operation Manual
FT040DB Series
8-bit Digital Series
4-ch Bi-directional Data
Fiber Optic Converter
www.ot-systems.com 1
OT Systems Ltd., 2014
Rev 1.2
![](/html/24/2421/2421f4c97f253efbd4675517f86be67c0ea988b8f44768fb8692e299c36d5a4f/bg2.png)
FT040DB Series Installation & Operation Manual
Standalone Units
Single-Mode Transmitters
FT040DB-SSTRSA
FT040DB-SSTRLSA
Single-Mode Receivers
FT040DB-SSRTSA
FT040DB-SSRTLSA
Multi-Mode Transmitter
FT040DB-SMTRSA
Multi-Mode Receiver
FT040DB-SMRTSA
Card Modules
Single-Mode Transmitters
FT040DB-SSTR
FT040DB-SSTRL
Single-Mode Receivers
FT040DB-SSRT
FT040DB-SSRTL
Multi-Mode Transmitter
FT040DB-SMTR
Multi-Mode Receiver
FT040DB-SMRT
Models covered in this manual
Remark:
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg.
FT040DB-FSTR
www.ot-systems.com 2
![](/html/24/2421/2421f4c97f253efbd4675517f86be67c0ea988b8f44768fb8692e299c36d5a4f/bg3.png)
FT040DB Series Installation & Operation Manual
Table of Contents
(1) SAFETY INSTRUCTIONS .................................................................................................................................. 4
(2) PRODUCT OVERVIEW .................................................................................................................................... 5
2.1 INTRODUCTION ..................................................................................................................................................... 5
2.2 MODELS SELECTION TABLE ...................................................................................................................................... 6
(3) INSTALLATION................................................................................................................................................ 7
3.1 GENERAL ............................................................................................................................................................. 7
3.2 STANDALONE UNIT INSTALLATION .............................................................................................................................. 7
3.3 CARD MODULE INSTALLATION................................................................................................................................... 8
(4) CABLE CONNECTIONS & SETUP PROCEDURES ................................................................................................ 8
4.1 SYSTEM CABLE CONNECTIONS ................................................................................................................................. 8
4.2 DATA, AUDIO & CONTACT CLOSURE PORTS ASSIGNMENTS AND PIN CONNECTIONS............................................................ 10
4.3 DIP SWITCH SETTING PROCEDURES .......................................................................................................................... 11
4.4 GROUND CONNECTION ......................................................................................................................................... 13
(5) OPERATIONAL GUIDES ................................................................................................................................. 14
5.1 FT040DB SERIES TRANSMITTER ............................................................................................................................ 14
5.2 FT040DB SERIES RECEIVER .................................................................................................................................. 14
(6) SPECIFICATIONS ........................................................................................................................................... 15
(7) DRAWINGS .................................................................................................................................................. 16
(8) WARRANTY INFORMATION ......................................................................................................................... 16
(9) CONTACT INFORMATION ............................................................................................................................. 17
www.ot-systems.com 3
![](/html/24/2421/2421f4c97f253efbd4675517f86be67c0ea988b8f44768fb8692e299c36d5a4f/bg4.png)
FT040DB Series Installation & Operation Manual
(1) Safety Instructions
Please be familiar with all information in this manual prior to installation and
operation.
Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following
safety precautions apply.
Warning: Do not disconnect the fiber optic connector while the unit is powered up.
Exposure to Class I invisible optical radiation is possible when the internal fiber optic
connector is disconnected while the unit is powered up.
Caution: Any access to the controls, adjustments, or performing operations, which are
other than those specified may result in hazardous radiation exposure. Permanent eye
damage or other bodily injuries may be resulted from such exposure even for only
seconds.
Note 2: This assembly contains parts sensitive to damage by electrostatic discharge (ESD). ESD
precautionary procedures should be applied in the course of touching, removing or inserting parts
or assemblies.
www.ot-systems.com 4
![](/html/24/2421/2421f4c97f253efbd4675517f86be67c0ea988b8f44768fb8692e299c36d5a4f/bg5.png)
FT040DB Series Installation & Operation Manual
(2) Product Overview
2.1 Introduction
The FT040DB Series products comprise of either single-mode or multi-mode fiber optic
transmitters and receivers for the optical transmission of FOUR bi-directional (Tx ↔ Rx) data
signals on one fiber. The products work at wavelengths of 1310nm and 1550nm with either a
9/125um or 62.5/125um fiber for single-mode or multi-mode transmission respectively.
Transparent data transmission is accomplished in RS232, RS422 and RS485 formats
regardless of the type of communication protocol implemented within the system. Time Division
Multiplex (TDM) technology is employed for digital transmission of forward video and data;
whereas optical Wavelength Division Multiplex (WDM) technology is employed for simultaneous
reverse data transmission as well as bi-directional data transmission.
For single-mode transmission, we also offer specifically designed products for long-haul
transmissions up to 60km. These models include the letter “L” in the suffix, e.g. FT040DB-SSTRL
for Tx, FT040DB-SSRTL for Rx, etc.
The FT040DB Series units are available as standalone units, which can be mounted
horizontally or vertically wall-mounted on any fixture. The standalone unit comes with an external
power supply FT-PA/12V, which can be powered by local 110/220V power.
The FT040DB Series units are also available as plug-in card modules installed in a 19”
rack-mount chassis. Each plug-in card occupies one slot in the rack-mount chassis. The rack
mount chassis has to be ordered separately, and comes with its own power supply for powering
the installed card modules.
www.ot-systems.com 5
![](/html/24/2421/2421f4c97f253efbd4675517f86be67c0ea988b8f44768fb8692e299c36d5a4f/bg6.png)
FT040DB Series Installation & Operation Manual
Installation
requirements
Single-mode 4 bi-directional Data
Transmitter Standalone unit
Horizontally or
vertically
wall-mounted
Standalone
unit
FT-PA/12V
external
power supply
is included
for the
Standalone
unit
2
Single-mode Long-haul 4 bi-directional
Data Transmitter Standalone unit
Single-mode 4 bi-directional Data
Receiver Standalone unit
Single-mode Long-haul 4 bi-directional
Data Receiver Standalone unit
Multi-mode 4 bi-directional Data Receiver
Standalone unit
Multi-mode Long-haul 4 bi-directional Data
Receiver Standalone unit
Single-mode 4 bi-directional Data
Transmitter Card Module
Housed in
FT-C18
chassis
3
FT-C18
chassis has
to be
ordered
separately
Single-mode Long-haul 4 bi-directional
Data Transmitter Card Module
Single-mode 4 bi-directional Data
Receiver Card Module
Single-mode Long-haul 4 bi-directional
Data Receiver Card Module
Multi-mode 4 bi-directional Data
Transmitter Card Module
Multi-mode 4 bi-directional Data Receiver
Card Module
2.2 Models selection table
1
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT040DB-FSTR
2
FT-PA/12V works under 100 -240VAC, 50/60Hz power supply
3
Refer to FT-C18 product manual for specifications
www.ot-systems.com 6