OT Systems FT010DB User Manual

FT010DB Series Installation & Operation Manual
Installation and Operation Manual
8-bit Digital Series
1-ch Bi-directional Data Fiber Optic Converter
www.ot-systems.com 1
OT Systems Ltd., 2014
Rev 1.2
FT010DB Series Installation & Operation Manual
Standalone Units
Single-Mode Transmitters FT010DB-SSTRSA FT010DB-SSTRLSA
Single-Mode Receivers FT010DB-SSRTSA FT010DB-SSRTLSA
Multi-Mode Transmitter FT010DB-SMTRSA
Multi-Mode Receiver FT010DB-SMRTSA
Card Modules
Single-Mode Transmitters FT010DB-SSTR FT010DB-SSTRL
Single-Mode Receivers FT010DB-SSRT FT010DB-SSRTL
Multi-Mode Transmitter FT010DB-SMTR
Multi-Mode Receiver FT010DB-SMRT
Models covered in this manual
Remark:
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT010DB-FSTR
www.ot-systems.com 2
FT010DB Series Installation & Operation Manual
Table of Contents
(1) SAFETY INSTRUCTIONS .................................................................................................................................. 4
(2) PRODUCT OVERVIEW .................................................................................................................................... 5
2.1 INTRODUCTION ..................................................................................................................................................... 5
2.2 MODELS SELECTION TABLE ...................................................................................................................................... 6
(3) INSTALLATION................................................................................................................................................ 7
3.1 GENERAL ............................................................................................................................................................. 7
3.2 STANDALONE UNIT INSTALLATION .............................................................................................................................. 7
3.3 CARD MODULE INSTALLATION................................................................................................................................... 8
(4) CABLE CONNECTIONS & SETUP PROCEDURES ................................................................................................ 8
4.1 SYSTEM CABLE CONNECTIONS ................................................................................................................................. 8
4.2 DATA, AUDIO & CONTACT CLOSURE PORTS ASSIGNMENTS AND PIN CONNECTIONS............................................................ 10
4.3 DIP SWITCH SETTING PROCEDURES .......................................................................................................................... 11
4.4 GROUND CONNECTION ......................................................................................................................................... 13
(5) OPERATIONAL GUIDES ................................................................................................................................. 14
5.1 FT010DB SERIES TRANSMITTER ............................................................................................................................ 14
5.2 FT010DB SERIES RECEIVER .................................................................................................................................. 14
(6) SPECIFICATIONS ........................................................................................................................................... 15
(7) DRAWINGS .................................................................................................................................................. 16
(8) WARRANTY INFORMATION ......................................................................................................................... 16
(9) CONTACT INFORMATION ............................................................................................................................. 17
www.ot-systems.com 3
FT010DB Series Installation & Operation Manual
(1) Safety Instructions
Please be familiar with all information in this manual prior to installation and operation.
Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following
safety precautions apply.
Warning: Do not disconnect the fiber optic connector while the unit is powered up. Exposure to Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up.
Caution: Any access to the controls, adjustments, or performing operations, which are other than those specified may result in hazardous radiation exposure. Permanent eye damage or other bodily injuries may be resulted from such exposure even for only seconds.
Note 2: This assembly contains parts sensitive to damage by electrostatic discharge (ESD). ESD precautionary procedures should be applied in the course of touching, removing or inserting parts or assemblies.
www.ot-systems.com 4
FT010DB Series Installation & Operation Manual
(2) Product Overview
2.1 Introduction
The FT010DB Series products comprise of either single-mode or multi-mode fiber optic transmitters and receivers for the optical transmission of ONE bi-directional (Tx ↔ Rx) data signals on one fiber. The products work at wavelengths of 1310nm and 1550nm with either a 9/125um or 62.5/125um fiber for single-mode or multi-mode transmission respectively.
Transparent data transmission is accomplished in RS232, RS422 and RS485 formats regardless of the type of communication protocol implemented within the system. Time Division Multiplex (TDM) technology is employed for digital transmission of forward video and data; whereas optical Wavelength Division Multiplex (WDM) technology is employed for simultaneous reverse data transmission as well as bi-directional data transmission.
For single-mode transmission, we also offer specifically designed products for long-haul transmissions up to 60km. These models include the letter “L” in the suffix, e.g. FT010DB-SSTRL for Tx, FT010DB-SSRTL for Rx, etc.
The FT010DB Series units are available as standalone units, which can be mounted horizontally or vertically wall-mounted on any fixture. The standalone unit comes with an external power supply FT-PA/12V, which can be powered by local 110/220V power.
The FT010DB Series units are also available as plug-in card modules installed in a 19” rack-mount chassis. Each plug-in card occupies one slot in the rack-mount chassis. The rack mount chassis has to be ordered separately, and comes with its own power supply for powering the installed card modules.
www.ot-systems.com 5
FT010DB Series Installation & Operation Manual
Type
Mode
Models1
Descriptions
Installation
requirements
Remarks
Standalone Units
Single-Mode
FT010DB-SSTRSA
Single-mode 1 bi-directional Data Transmitter Standalone unit
Horizontally or vertically wall-mounted Standalone unit
FT-PA/12V external power supply is included for the Standalone unit
2
FT010DB-SSTRLSA
Single-mode Long-haul 1 bi-directional Data Transmitter Standalone unit
FT010DB-SSRTSA
Single-mode 1 bi-directional Data Receiver Standalone unit
FT010DB-SSRTLSA
Single-mode Long-haul 1 bi-directional Data Receiver Standalone unit
Multi-Mode
FT010DB-SMTRSA
Multi-mode 1 bi-directional Data Receiver
Standalone unit
FT010DB-SMRTSA
Multi-mode Long-haul 1 bi-directional Data
Receiver Standalone unit
Card Modules
Single-Mode
FT010DB-SSTR
Single-mode 1 bi-directional Data Transmitter Card Module
Housed in FT-C18 chassis
3
FT-C18 chassis has to be ordered separately
FT010DB-SSTRL
Single-mode Long-haul 1 bi-directional Data Transmitter Card Module
FT010DB-SSRT
Single-mode 1 bi-directional Data Receiver Card Module
FT010DB-SSRTL
Single-mode Long-haul 1 bi-directional Data Receiver Card Module
Multi-Mode
FT010DB-SMTR
Multi-mode 1 bi-directional Data Transmitter Card Module
FT010DB-SMRT
Multi-mode 1 bi-directional Data Receiver Card Module
2.2 Models selection table
1
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT010DB-FSTR
2
FT-PA/12V works under 100 -240VAC, 50/60Hz power supply
3
Refer to FT-C18 product manual for specifications
www.ot-systems.com 6
FT010DB Series Installation & Operation Manual
Fig. 3.1 Standalone unit
Fig. 3.2 FT-C18 chassis
(3) Installation
3.1 General
All OT Systems products are thoroughly inspected, tested and securely packaged before delivery to ensure a stable, intact and trouble-free service. Please check the equipment upon receipt for any visible damage which may have been caused during shipping.
The FT010DB Series standalone units (Fig.3.1) can be either horizontally or vertically wall-mounted, or mounted on any fixture. The Standalone unit works with an external power supply FT-PA/12V powered by local 110/220V power.
The FT010DB Series card modules are housed inside the FT-C18 rack-mount chassis (Fig.
3.2) with an included power supply unit. The whole chassis is powered by local 110/220V power. FT-C18 is a standard 19” (483mm) rack-mount chassis which occupies 4 rack units (177.8mm) in height. Each FT010DB card module occupies one slot and a total of 18 cards can be housed inside the chassis.
3.2 Standalone unit installation
a) Mount the standalone unit onto a fixture, (either on the wall or on a flat surface) with four screws through the holes on the mounting frame to secure it in position. b) The provided power supply should also be mounted on the same fixture or in the proximity for connection of the supply cables to the unit, provided that an AC power supply socket is nearby for powering the adaptor. c) Connect all the signal inputs and outputs at the back of the unit with appropriate cables: fiber optic cable for optical link, and UTP cables for data input/output (Tx/Rx). d) Once the unit is powered up, check that the red POWER LED on the unit is lit. If not, check the power supply cable connections between the unit and the power supply socket. e) With all the signals available at the input and output ports, check the status of LEDs located on the unit. With correct status of each LED, installation is now completed [for LEDs status, see Operational Guides on this manual’s section (5)].
www.ot-systems.com 7
FT010DB Series Installation & Operation Manual
Signal Type
Cable Type
Connector
Optical
Single-mode or Multi-mode fiber
ST (or FC) Connector
Data
Twisted-pair Cable
Screw Terminal Block
3.3 Card module installation
a) Insert the card module into the FT-C18 chassis along the top and bottom card guides of an empty slot and push the card into the multi-pin socket at the rear firmly. Secure with the provided thumb screws. b) Repeat the above procedure for all the rest card modules. Unused slots must be covered with blank panels provided. c) Connect all the signal inputs and outputs at the back of the unit with appropriate cables: fiber optic cable for optical link, and UTP cables for data input/output (Tx/Rx). d) Once the chassis is powered up, check that the red POWER LED on the front and back panels of the card modules are lit. If not, check the power supply cable connections between the chassis and the power supply socket. For failures of individual card’s POWER LEDs, check the corresponding card modules, whether they have been inserted properly. e) With all the signals available at the input and output ports, check the status of LEDs located on the unit. With correct status of each LED, installation is now completed [for LEDs status, see
Operational Guides on this manual’s section (5)].
(4) Cable Connections & Setup Procedures
4.1 System Cable Connections
Typical System Cable Connections Diagrams:
Standalone Transmitter Standalone Receiver
Fig. 4.1 Standalone unit to Standalone unit connection diagram
www.ot-systems.com 8
FT010DB Series Installation & Operation Manual
Standalone Transmitter Card Module Receiver
Fig. 4.2 Standalone unit to Card Module connection diagram
Card Module Transmitter Card Module Receiver
Fig. 4.3 Card Module to Card Module connection diagram
www.ot-systems.com 9
FT010DB Series Installation & Operation Manual
Pin Assignment
(Screw Terminal
Block)
Data format
1 2 3 4 5 6 7
RS422/485 (4-Wire)
IN(+)
IN(-)
OUT(+)
OUT(-)
N/A
N/A
N/A
RS485 (2-Wire)
IN/OUT (+)
IN/OUT (-)
N/A
N/A
N/A
N/A
N/A
RS232
N/A
N/A
N/A
N/A
IN
OUT
Sig. COM
User’s Equipment
DATA PORT
(7-PIN)
DATA PORT
(7-PIN)
User’s Equipment
TX(+)
1 IN(+)
1 IN(+)
TX(+)
TX(-)
2 IN(-)
2 IN(-)
TX(-)
RX(+)
3 OUT(+)
3 OUT(+)
RX(+)
RX(-)
4 OUT(-)
4 OUT(-)
RX(-)
5 N/A
5 N/A
6 N/A
6 N/A
7 N/A
7 N/A
User’s Equipment
DATA PORT
(7-PIN)
DATA PORT
(7-PIN)
User’s Equipment
TX/RX(+)
1 IN/OUT(+)
1 IN/OUT(+)
TX/RX(+)
TX/RX(-)
2 IN/OUT(-)
2 IN/OUT(-)
TX/RX(-)
3 N/A
3 N/A
4 N/A
4 N/A
5 N/A
5 N/A
6 N/A
6 N/A
7 N/A
7 N/A
4.2 Data, Audio & Contact Closure ports assignments and pin connections
4.2.1 Data connections
For data input and output connections, please note the following pin assignment:
4-Wire RS422/485 Full Duplex Data communication connection diagram:
Transmitter End Receiver End
2-Wire RS485 Half Duplex Data communication connection diagram:
www.ot-systems.com 10
Fig. 4.4.1 Connector Pin Assignments for 4-wire RS422/485 data format at Data port
Transmitter End Receiver End
Fig. 4.4.2 Connector Pin Assignments for 2-wire RS485 data format at Data port.
FT010DB Series Installation & Operation Manual
User’s Equipment
DATA PORT
(7-PIN)
DATA PORT
(7-PIN)
User’s Equipment
1 N/A
1 N/A
2 N/A
2 N/A
3 N/A
3 N/A
4 N/A
4 N/A
TX 5 IN
5 IN
TX
RX 6 OUT
6 OUT
RX
Sig. COM
7 Sig. COM
7 Sig. COM
Sig. COM
(a) Dip switches on FT010DB Series Standalone unit
RS232 Data communication connection diagram:
Transmitter End Receiver End
Fig. 4.4.3 Connector Pin Assignments for RS232 data format at Data port
4.3 Dip switch setting procedures
The only setup procedure is to select the appropriate line terminations and data transmission formats. Selections must be made by setting the dip switches through the access on the front panel (see Fig. 4.5).
Fig. 4.5 Location of Dip Switches
www.ot-systems.com 11
(b) Dip switches on FT010DB Series Card Module
FT010DB Series Installation & Operation Manual
Function / Switch No.
Sw. 3
Sw. 4
RS485 (2-Wire)
OFF
OFF
RS422/485 (4-Wire)*
OFF
ON
RS232
ON
OFF
Function / Switch No.
Sw. 1
Line Output Terminated
ON
Line Output Unterminated*
OFF Function / Switch No.
Sw. 2
Line Input Terminated
ON
Line Input Unterminated*
OFF
Dip switch settings for various types of data transmissions
* Factory setting [RS422/485 (4-Wire)]
Dip switch settings for line terminations
Line Output Termination Line Input Termination
* Factory setting (Line Output and Line Input “Unterminated”)
Industrial practice for line terminations
For RS422 4-wire communication, it is suggested to keep the input and output lines terminated in the ONE Tx to ONE Rx configuration.
For RS485 2/4-wire communication, the RS485 device can be disabled to stay in a Hi-Z state. It is very important that the data lines have to be terminated with a resistor being connected across the pair wires so as to eliminate the residual standing signal waves on the lines in the Hi-Z line condition. So, it is recommended that the lines should be terminated with the appropriate resistance. When more than one RS485 device are connected in a daisy-chain configuration, only the farthest device on the loop, i.e. the device located at the end of the line, should be terminated; whereas the middles ones are set to “Unterminated” status. See the figure
4.6 below for reference.
(a) RS485/422 4-wires Bus structure (b) RS485 2-wire Bus structure
www.ot-systems.com 12
Fig. 4.6 Termination of different Bus structures
FT010DB Series Installation & Operation Manual
4.4 Ground connection
For enhanced safety to reduce the risks of electrical shock and physical damage, caused by lightning and other power surges, as well as a connection to the surge suppresion devices in the product, a screw terminal is provided on the Standalone cabinets (Fig. 4.7). It is highly recommended that the Standalone unit have good ground connections to the buildings ground in accordance with the local codes.
Fig. 4.7 Standalone unit earth ground terminal location
www.ot-systems.com 13
FT010DB Series Installation & Operation Manual
Indicator
Color
Description
PWR
Red
Lit when power is supplied to the Transmitter.
OL
Yellow
Lit when optical signal from receiver to transmitter is active.
DATA
IN
Red
Blinks when input data is available at Tx.
OUT
Green
Blinks when output data is available at Tx.
OPT -
ST (or FC) Optical Connector for fiber cable connection.
DATA -
7-pin Screw Terminal Block for data signal.
Indicator
Color
Description
PWR
Red
Lit when power is supplied to the Receiver.
OL
Yellow
Lit when optical signal from transmitter to receiver is active.
DATA
IN
Red
Blinks when input data is available at Rx.
OUT
Green
Blinks when output data is available at Rx.
OPT -
ST (or FC) Optical Connector for fiber cable connection.
DATA -
7-pin Screw Terminal Block for data signal.
(5) Operational Guides
5.1 FT010DB Series Transmitter
LED Indicators
.
Signal Ports
5.2 FT010DB Series Receiver
LED Indicators
Signal Ports
www.ot-systems.com 14
FT010DB Series Installation & Operation Manual
MODELS*
PARAMETERS
FT010DB-SSTR(RT)SA FT010DB-SSTR(RT) (Single-Mode)
FT010DB-SSTR(RT)LSA FT010DB-SSTR(RT)L (Single-Mode)
FT010DB-SMTR(RT)SA FT010DB-SMTR(RT) (Multi-Mode)
OPTICAL
No. of Fiber / Connector
1 / ST (or FC)
1 / ST (or FC)
1 / ST (or FC)
Wavelength
1310/1550 nm
1550/1310 nm
1310/1550 nm
Optical Power Budget
17 dB
24 dB
23 dB
Max Distance (km)
40 km
60 km
4 km
DATA
Channel / Connector
1 / 7-pin Screw Terminal
Direction
Bi-directional (Duplex)
Electrical Format
RS232, RS422, RS485 (2-wire, 4-wire) Tri-state
Transmission Rate
0~256 Kbps
POWER
Power consumption
12VDC @ 3.6W
Power Supply
Standalone unit: FT/PA12V DC Adaptor
Card module: Powered by FT-C18 chassis
Connector (Standalone unit)
2-pin Screw Terminal
PHYSICAL
Weight
Standalone unit: 0.6 kg Card module: 0.16 kg
Dimensions (W x H x D)
Standalone unit: 156 x 30.5 x 223 mm (MAX)
Card module: 148 x 20.4 x 213 mm (MAX)
ENVIRONMENTAL
Operating Temperature
-40oC ~ +75oC
Storage Temperature
-40oC ~ +85oC
Relative Humidity
0 ~ 95% non-condensing
MTBF
>100’000 Hours
*If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT010DB-FSTR
(6) Specifications
www.ot-systems.com 15
FT010DB Series Installation & Operation Manual
(7) Drawings
Fig. 7.1 Dimensional drawings of Standalone unit (mm)
(8) Warranty Information
All OT Systems FT Series products are subject to a limited life-time warranty offered by the company in normal circumstances. Please refer to the OT Systems Products Warranty Statement for details. Access to the statement is available in our company website at
www.ot-systems.com.
www.ot-systems.com 16
FT010DB Series Installation & Operation Manual
(9) Contact Information
APAC Operation
Address: Unit 1023, 10/F, Landmark North, 39 Lung Sum Avenue, Sheung Shui, N.T., Hong Kong Tel: (852) 2672 5153 Fax: (852) 2679 0756 Sales Inquiries
sales@ot-systems.com
Technical Support
techsupport@ot-systems.com
EMEA Operation
Address: J. Slovackio str. 4, LT-11107, Vilnius, Lithuania
Tel: (370) 60730087 Fax: (370) 52051855 Sales Inquiries
sales@ot-systems.com
Technical Support
techsupport@ot-systems.com
AMERICAS Operation
Address: 18 West Main Street, Plano, IL 60545, U.S.A.
Tel: (1) 630 554 9178 Fax: (1) 630 554 9179 Sales Inquiries
sales.usa@ot-systems.com
Technical Support
techsupport.usa@ot-systems.com
www.ot-systems.com 17
Loading...