Models covered in this manual
Standalone units
Fiber connector in SC
Multi-Mode (2-Fiber)
ET2111-A-SA
Single-Mode (2-Fiber)
ET2111-B-SA
Multi-Mode (1-Fiber)
ET2111-C-SA ET2111-D-SA
Single-Mode (1-Fiber)
ET2111-E-SA ET2111-F-SA
Fiber connector in ST
Multi-Mode (2-Fiber)
ET2111-G-SA
Single-Mode (2-Fiber)
ET2111-H-SA
Multi-Mode (1-Fiber)
ET2111-I-SA ET2111-J-SA
Single-Mode (1-Fiber)
ET2111-K-SA ET2111-L-SA
Card Modules
Fiber connector in SC
Multi-Mode (2-Fiber)
ET2111-A-CM
Single-Mode (2-Fiber)
ET2111-B-CM
Multi-Mode (1-Fiber)
ET2111-C-CM ET2111-D-CM
Single-Mode (1-Fiber)
ET2111-E-CM ET2111-F-CM
Fiber connector in ST
Multi-Mode (2-Fiber)
ET2111-G-CM
Single-Mode (2-Fiber)
ET2111-H-CM
Multi-Mode (1-Fiber)
ET2111-I-CM ET2111-J-CM
Single-Mode (1-Fiber)
ET2111-K-CM ET2111-L-CM
ET2111 Series Installation & Operation Manual
www.ot-systems.com 3
Table of Contents
TABLE OF CONTENTS............................................................................................................................................... 3
(1) SAFETY INSTRUCTIONS .................................................................................................................................. 4
(2) PRODUCT OVERVIEW .................................................................................................................................... 5
2.1 INTRODUCTION ..................................................................................................................................................... 5
2.2 PRODUCTS HIGHLIGHTS .......................................................................................................................................... 5
2.3 MODELS SELECTION TABLE ...................................................................................................................................... 6
(3) INSTALLATION................................................................................................................................................ 7
3.1 GENERAL ............................................................................................................................................................. 7
3.2 PACKAGE CONTENTS .............................................................................................................................................. 7
3.3 SELECTING A SITE FOR THE SWITCH ........................................................................................................................... 8
3.4 CONNECTING TO POWER ........................................................................................................................................ 8
DC Jack Power Input ......................................................................................................................................... 8
DC Power Input .................................................................................................................................................. 8
3.5 INSTALLATION ....................................................................................................................................................... 9
(4) CABLE CONNECTIONS & SETUP PROCEDURES .............................................................................................. 11
4.1 SYSTEM CABLE CONNECTIONS ................................................................................................................................ 11
4.2 CONNECTING TO YOUR NETWORK .......................................................................................................................... 12
4.2.1 The 10/100Base-TX Connector ....................................................................................................... 12
4.2.2 The 100Base-FX Connectors ........................................................................................................... 13
(5) OPERATIONAL GUIDES ................................................................................................................................. 14
5.1 LEDS STATUS...................................................................................................................................................... 14
5.2 SIGNAL AND POWER PORTS ................................................................................................................................... 14
(6) SPECIFICATIONS ........................................................................................................................................... 15
(7) DRAWINGS .................................................................................................................................................. 17
(8) WARRANTY INFORMATION ......................................................................................................................... 17
(9) CONTACT INFORMATION ............................................................................................................................. 18
APPENDIX A ............................................................................................................................................................ A
1. CONNECTOR PINOUTS ................................................................................................................................... A
ET2111 Series Installation & Operation Manual
www.ot-systems.com 4
(1) Safety Instructions
Please be familiar with all information in this manual prior to installation and operation.
Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following
safety precautions apply.
Warning: Do not disconnect the fiber optic connector while the unit is powered up. Exposure to Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up.
Caution: Any access to the controls, adjustments, or performing operations, which are other than those specified, may result in hazardous radiation exposure. Permanent eye damage or other bodily injuries may be resulted from such exposure even for only seconds.
Note 2: This assembly contains parts sensitive to damage by electrostatic discharge (ESD). ESD precautionary procedures should be applied in the course of touching, removing or inserting parts or assemblies.
ET2111 Series Installation & Operation Manual
www.ot-systems.com 5
(2) Product Overview
2.1 Introduction
OT Systems' ET2111 media converter offers an easy and affordable solution for network managers to connect 10/100 Fast Ethernet from UTP to fiber optic cabling. The switch uses a high performance auto-sensing exchange chip for full functionality of transfer and exchange, guaranteeing the safety and stability of data transfer. The switches are Standalone Wall-mount and can also operate in ET-C12 rack mount chassis, taking care of different installations.
2.2 Products Highlights Basic Features
Converts 10/100Base-TX to 100Base-FX Full/Half duplex, Auto-Negotiation Singlemode or Multimode fiber operation Single or Dual-core fiber with SC or ST connectors Store and forward switching mechanism MDI/MDI-X Auto-Crossover supported Plug-and-Play -20 °C to 60 °C (-4 °F to 140 °F) operating temperature Wall-mount or operate in ET-C12 rack mount chassis.
ET2111 Series Installation & Operation Manual
www.ot-systems.com 6
2.3 Models selection table
Models
Descriptions
Fiber Options
Wavelengths
Links
Budget
Max.
Distance
Installation
requirements
ET2111-A-SA
Multimode/2-fiber/SC
1310nm
14dB
2Km
Horizontally or vertically wall-mounted Standalone unit
1
ET2111-B-SA
Singlemode/2-fiber/SC
1310nm
21dB
20Km
ET2111-C-SA
Multimode/WDM 1-fiber/SC
TX:1310nm/RX1550nm
21dB
2Km
ET2111-D-SA
Multimode/WDM 1-fiber/SC
TX:1550nm/RX1310nm
21dB
2Km
ET2111-E-SA
Singlemode/WDM 1-fiber/SC
TX:1310nm/RX1550nm
19dB
20Km
ET2111-F-SA
Singlemode/WDM 1-fiber/SC
TX:1550nm/RX1310nm
19dB
20Km
ET2111-G-SA
Multimode/2-fiber/ST
1310nm
14dB
2Km
ET2111-H-SA
Singlemode/2-fiber/ST
1310nm
21dB
20Km
ET2111-I-SA
Multimode/WDM 1-fiber/ST
TX:1310nm/RX1550nm
21dB
2Km
ET2111-J-SA
Multimode/WDM 1-fiber/ST
TX:1550nm/RX1310nm
21dB
2Km
ET2111-K-SA
Singlemode/WDM 1-fiber/ST
TX:1310nm/RX1550nm
19dB
20Km
ET2111-L-SA
Singlemode/WDM 1-fiber/ST
TX:1550nm/RX1310nm
19dB
20Km
ET2111-A-CM
Multimode/2-fiber/SC
1310nm
14dB
2Km
Housed in ET-C12 chassis
2
ET2111-B-CM
Singlemode/2-fiber/SC
1310nm
21dB
20Km
ET2111-C-CM
Multimode/WDM 1-fiber/SC
TX:1310nm/RX1550nm
21dB
2Km
ET2111-D-CM
Multimode/WDM 1-fiber/SC
TX:1550nm/RX1310nm
21dB
2Km
ET2111-E-CM
Singlemode/WDM 1-fiber/SC
TX:1310nm/RX1550nm
19dB
20Km
ET2111-F-CM
Singlemode/WDM 1-fiber/SC
TX:1550nm/RX1310nm
19dB
20Km
ET2111-G-CM
Multimode/2-fiber/ST
1310nm
14dB
2Km
ET2111-H-CM
Singlemode/2-fiber/ST
1310nm
21dB
20Km
ET2111-I-CM
Multimode/WDM 1-fiber/ST
TX:1310nm/RX1550nm
21dB
2Km
ET2111-J-CM
Multimode/WDM 1-fiber/ST
TX:1550nm/RX1310nm
21dB
2Km
ET2111-K-CM
Singlemode/WDM 1-fiber/ST
TX:1310nm/RX1550nm
19dB
20Km
ET2111-L-CM
Singlemode/WDM 1-fiber/ST
TX:1550nm/RX1310nm
19dB
20Km
1
ET-PA/12V 1.25A 12VDC power adapter works under 100-240VAC, 50/60Hz power supply; DC Jack(US, European, UK or
Australian power plug available)
2
Refer to ET-C12 for specifications.
ET2111 Series Installation & Operation Manual
www.ot-systems.com 7
(3) Installation
3.1 General
All OT Systems products are thoroughly inspected, tested and securely packaged before delivery to ensure a stable, intact and trouble-free service. Please check the equipment upon receipt for any visible damage which may have been caused during shipping.
3.2 Package Contents
When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.
Ethernet Switch Quick Installation Guide External power adapter & Power Cord (for Standalone Wall-mount type)
The Standalone type ET2111 Series (Fig. 3.1) can be either horizontally or vertically wall-mounted, or fits within the most camera housings, etc. It works with an external 12VDC power supply.
Fig. 3.1 ET2111
The Card module can be used as slide-in module to the 19” 3U high converter rack ET-C12. See Fig.3.2(a) for the 12-slot Rack Mount Chassis which can be purchased separately; Fig.3.2(b) for card module.
Fig. 3.2 (a) ET -C12
Fig. 3.2 (b) Card module
ET2111 Series Installation & Operation Manual
www.ot-systems.com 8
3.3 Selecting a site for the Switch
As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
- The ambient temperature should be between -20 to +60 degrees Celsius.
- The relative humidity should be less than 95 percent, non-condensing.
- Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards.
- Make sure that the switch receives adequate ventilation.
- The power outlet should be within 1.8 meters of the switch.
3.4 Connecting to Power
Standalone Wall-mount
Card module
Rear panel
* The 5-PIN golden finger should be inside the square space that reserve for power input from the 5-PIN connector at ET-C12. The DC
Jack should be covered by the cover panel for power of the card model by using 2 screws.
3.4.1 Standalone Wall-mount Power Input Assignment
DC IN 12V
Inner
12V
Outer
GND
Size of DC JACK outside diameter (OD): 2.5mm; Length of the DC Jack:9.5mm
The tip (i.e. the inner conductor) carries the positive (+) pole.
DC Jack Power Input
Step 1: Connect the DC power cord to the DC jack on the rear of switch and then plug it
into a standard DC outlet.
Step 2: Disconnect the power cord if you want to shut down the switch.
3.4.2 Card module DC Power Input
Step 1: Connect the DC power cord at the rear of ET-PSU/5V and then turn it on for
power up the card modules within the ET-C12.
Step 2: The Card Module can be removed as slide-out module form the ET-C12 (12-slot
Rack Mount Chassis). “Hot-swap” allows any module to be removed and restored without affecting the operation of any other. Or switch off the ET-PSU/5V to shut down all switches in the ET-C12.
ET2111 Series Installation & Operation Manual
www.ot-systems.com 9
3.5 Installation
This chapter gives step-by-step instructions about how to install the switch:
3.5.1 Standalone wall mount type
a) Mount the ET2111 onto a fixture or camera housings, e.g. a plank, (either on the
wall or on a flat surface) with four screws through the holes on the mounting frame to secure it in position.
(a) Top view
(b) Side view
Fig. 3.5 Dimension of Micro type units
b) The power supply should also be mounted on the same fixture or in the proximity
for connection of the supply cables to the unit, provided that an AC power supply socket is nearby for powering the adaptor.
c) Connect all the signal inputs and outputs at the unit with appropriate cables: fiber
optic cable for optical link and UTP/STP Cat 5 cable for Ethernet. Please refer to Section 4.1 for the details.
d) Once the unit is powered up, check that the POWER LED on the unit is lit. If not,
check the power supply cable connections between the unit and the power supply socket.
e) With all the signals available at the physical ports, check the status of LEDs
located on the unit. With correct status of each LED, installation is now completed [for LEDs status, see Operational Guides on this manual’s Section (5)].
ET2111 Series Installation & Operation Manual
www.ot-systems.com 10
3.5.2 Card Module
a) Insert the card module into the ET-C12 chassis along the top and bottom card guides of
an empty slot and push the card into the multi-pin socket at the rear firmly. Secure with the provided thumb screws.
b) Repeat the above procedure for all the rest card modules. Unused slots must be covered
with blank panels provided.
c) Connect all the signal inputs and outputs at the unit with appropriate cables: fiber
optic cable for optical link and UTP/STP Cat 5 cable for Ethernet. Please refer to Section 4.1 for the details.
d) Once the unit is powered up by ET-PSU/5V, check that the POWER LED on the
unit is lit. If not, check the power supply cable connections between the chassis and the power supply socket and the connections between the card module and ET-C12.
e) With all the signals available at the physical ports, check the status of LEDs
located on the unit. With correct status of each LED, installation is now completed [for LEDs status, see Operational Guides on this manual’s Section (5)].
ET2111 Series Installation & Operation Manual
www.ot-systems.com 11
(4) Cable Connections & Setup Procedures
4.1 System cable connections
Signal
Type
Cable Type
Connector
For details, please refer to
Optical
Single-mode or Multi-mode fiber
SC or ST Connector
Section 4.2.2
Ethernet
Twisted-pair Cable 10BASE-T: UTP/STP Cat3, 4, 5 100BASE-TX: UTP/STP Cat 5
RJ45 Connector
Section 4.2.1
12VDC
Power cord
DC JACK (Standalone Wall-mount type) or Golden finger (Card Module) within the ET-C12
Section 3.4
Wiring Diagram
Fig 4.1 Switches connection diagram
ET2111 Series Installation & Operation Manual
www.ot-systems.com 12
4.2 Connecting to Your Network Cable Type & Length
It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.
Cable Specifications
Speed
Connector
Port Speed Half/Full Duplex
Cable
Max. Distance
10Base-T
RJ-45
10/20 Mbps
2-pair UTP/STP Cat. 3, 4, 5
100 m
100Base-TX
RJ-45
100/200 Mbps
2-pair UTP/STP Cat. 5
100 m
100Base-FX
SC, ST
100/200 Mbps
MMF (50 or 62.5μm)
2 km
100Base-FX
SC, ST
100/200 Mbps
SMF (9 or 10μm)
20km
Cabling
Step 1: First, ensure the power of the Switch and end devices are turned off. <Note> Always ensure that the power is off before any installation. Step 2: Prepare cable with corresponding connectors for each type of port in use. Step 3: Consult the previous section for cabling requirements based on connectors and speed. Step 4: Connect one end of the cable to the Switch and the other end to a desired device. Step 5: Once the connections between two end devices are made successfully, turn on the power and the Switch is operational.
4.2.1 The 10/100Base-TX Connector
A standard straight through cable is used for the connection between the Ethernet switch and device. The products feature an auto-MDIX capability. For the details, Please see Appendix A for your reference.
ET2111 Series Installation & Operation Manual
www.ot-systems.com 13
4.2.2 The 100Base-FX Connectors
The 100Base-FX Connections
The fiber port pinouts
The TX (transmit) port of device I is connected to the RX (receive) port of device II, and the RX (receive) port of device I to the TX (transmit) port of device II.
X value:
A for Multimode fiber B for Singlemode fiber
FIBER
Connector
TX
SC Optical Connector
RX
SC Optical Connector
X value:
G for Multimode fiber H for Singlemode fiber
FIBER
Connector
TX
ST Optical Connector
RX
ST Optical Connector
The WDM 100Base-FX Connections
The fiber port pinouts Only ONE optical fiber core is required to transmit and receive data.
* Special note for choosing WDM products:
Pair of products should be used for the optical transmission by different wavelengths (Wavelengths in 1310nm, 1550nm). i.e. ET2111-C-YY should be match with ET2111-D-YY; ET2111-E-YY should be match with ET2111-F-YY ET2111-I-YY should be match with ET2111-J-YY; ET2111-K-YY should be match with ET2111-L-YY.
X value:
C and D for Multimode fiber E and F for Singlemode fiber
FIBER Connector
SC Optical Connector
X value:
I and J for Multimode fiber K and L for Singlemode fiber
FIBER Connector
ST Optical Connector
ET2111 Series Installation & Operation Manual
www.ot-systems.com 14
(5) Operational Guides
5.1 LEDs Status
5.2 Signal and Power Ports
FIBER -
SC or ST Optical Connector(s) for 100BASE-FX fiber cable connection.
NETWORK -
RJ45 with Cat. 5 for 10/100BASE-TX Ethernet connection.
DC IN-
DC Jack for 5V-12VDC power connection.
LED
State
Indication
PWR
Green
Power on.
Off
Power off.
FX LINK
Green
100Base-FX
SPD1, 2
Green
100Base-TX
Amber
10Base-TX
LINK/ ACT 1, 2
Steady
A valid network connection established
Flashing
Transmitting or receiving data. ACT Stands for Activity.
ET2111 Series Installation & Operation Manual
www.ot-systems.com 15
(6) Specifications
Ethernet
Standards
IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX/FX IEEE 802.3x
Processing Type
Store-and-Forward Half-duplex and IEEE802.3x Full-duplex flow control
Forward and Filter Rate
10Base-T 100Base-TX/FX
14,881pps (10Mbps) 148,810pps (100Mbps)
Cabling
10BASE-T 100BASE-TX
UTP/STP Cat. 3, 4, 5 or above UTP/STP Cat. 5 or above
Maximum Distance
Cat5 UTP
Up to 100m
Connector
10/100BASE-TX
2 X RJ45
Address table size:
2048MAC addresses
Optical
Cabling
62.5/125μm (Multi-mode) 9/125μm (Single-mode)
Maximum Distance
Multi-mode fiber
2Km
Single-mode fiber
20Km
Wavelength(s)
1310nm 1310/1550nm
Connector
SC or ST
Electrical and Mechanical
Input Power
12VDC (DC Jack by power adapter for standalone units) 5VDC (from ET-PSU/5V for card module)
Power Consumption
2.4W Max.
Operating Voltage & Max. Current Consumption
0.2A @ 12VDC
ET2111 Series Installation & Operation Manual
www.ot-systems.com 16
LED Indicators
Power
Power Status
10/100 TX (Per Port)
Link/Activity, Speed
100FX (Per Port)
Link/Activity
Dimensions
SA: 122 X 30 X 103mm CM: 130 X 31 X 111mm
Net Weight
SA: 0.33Kg (0.43kg including PA) CM: 0.33Kg
Casing
Aluminum case
Mounting Options
Wall-Mount
Card Module (in ET-C12 rack mount chassis)
Environmental
Operating Temperature
-20°C to 60°C (-4°F to 140°F)
Storage Temperature
-40°C to 85°C (-40°F to 185°F)
Humidity
0% - 95% non-condensing
Regulatory Approvals
ISO9001
FCC Part 15, Class A
EN55022: 2006 Class A
EN55024: 1998 +A1:2001+A2:2003
ET2111 Series Installation & Operation Manual
www.ot-systems.com 17
(7) Drawings
Fig. 7.1 Dimensional drawings of standalone wall-mount ET2111 (mm)
(8) Warranty Information
All OT Systems ET Series products are subject to a three-year limited warranty offered by the company in normal circumstances. Please refer to the OT Systems Products Warranty Statement for details. Access to the statement is available in our company website at
www.ot-systems.com.
ET2111 Series Installation & Operation Manual
www.ot-systems.com 18
(9) Contact Information
APAC Operation
Address: Unit 1023, 10/F, Landmark North, 39 Lung Sum Avenue, Sheung Shui, N.T., Hong Kong Tel: (852) 2672 5153 Fax: (852) 2679 0756 Sales Inquiries
sales@ot-systems.com
Technical Support
techsupport@ot-systems.com
EMEA Operation
Address: J. Slovackio str. 4, LT-11107, Vilnius, Lithuania
Tel: (370) 60730087 Fax: (370) 52051855 Sales Inquiries
sales@ot-systems.com
Technical Support
techsupport@ot-systems.com
AMERICAS Operation
Address: 18 West Main Street, Plano, IL 60545, U.S.A.
Tel: (1) 630 554 9178 Fax: (1) 630 554 9179 Sales Inquiries
sales.usa@ot-systems.com
Technical Support
techsupport.usa@ot-systems.com
ET2111 Series Installation & Operation Manual
www.ot-systems.com A
Appendix A
1. Connector Pinouts
RJ45 Connector (Male)
RJ45 Connector (Female)
2. TIA/EIA-568 Cabling
RJ45 Pin #
T568A
T568B
Wire Diagram
Wire Color
10Base-T Signal
100Base-TX Signal
Wire Diagram
Wire Color
10Base-T Signal
100Base-TX Signal
1 White/Green
Transmit+
White/Orange
Transmit+
2 Green
Transmit-
Orange
Transmit-
3 White/Orange
Receive+
White/Green
Receive+
4 Blue
Unused
Blue
Unused
5 White/Blue
Unused
White/Blue
Unused
6 Orange
Receive-
Green
Receive-
7 White/Brown
Unused
White/Brown
Unused
8 Brown
Unused
Brown
Unused
3. Standard, Straight-Through Wiring Diagram(both ends are the same):
The Straight-Through wiring (or called regular” Ethernet cable), both ends should be use the same pin out on of RJ45 port.
Loading...