OTS FT100-SSRSA, FT100-SSTLSA, FT100-SSRLSA, FT100-SSR, FT100-SSRL Installation And Operation Manual

...
FT100 Series Installation & Operation Manual
www.ot-systems.com 1
Installation and Operation Manual
FT100 Series
10-bit Digital Series
1-ch Video
Fiber Optic Converter
OT Systems Ltd., 2014
Rev 1.2
FT100 Series Installation & Operation Manual
www.ot-systems.com 2
Models covered in this manual
Standalone Units
Single-Mode Transmitters FT100-SSTSA FT100-SSTLSA
Single-Mode Receivers FT100-SSRSA FT100-SSRLSA
Multi-Mode Transmitter FT100-SMTSA
Multi-Mode Receiver FT100-SMRSA
Card Modules
Single-Mode Transmitters FT100-SST FT100-SSTL
Single-Mode Receivers FT100-SSR FT100-SSRL
Multi-Mode Transmitter FT100-SMT
Multi-Mode Receiver FT100-SMR
Remark:
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT100-FST
FT100 Series Installation & Operation Manual
www.ot-systems.com 3
Table of Contents
(1) SAFETY INSTRUCTIONS .................................................................................................................................. 4
(2) PRODUCT OVERVIEW .................................................................................................................................... 5
2.1 INTRODUCTION ..................................................................................................................................................... 5
2.2 MODELS SELECTION TABLE ...................................................................................................................................... 6
(3) INSTALLATION................................................................................................................................................ 7
3.1 GENERAL ............................................................................................................................................................. 7
3.2 STANDALONE UNIT INSTALLATION .............................................................................................................................. 7
3.3 CARD MODULE INSTALLATION................................................................................................................................... 8
(4) CABLE CONNECTIONS & SETUP PROCEDURES ................................................................................................ 8
4.1 SYSTEM CABLE CONNECTIONS .................................................................................................................................. 8
4.2 GROUND CONNECTION ......................................................................................................................................... 10
(5) OPERATIONAL GUIDES ................................................................................................................................. 11
5.1 FT100 SERIES TRANSMITTER ................................................................................................................................ 11
5.2 FT100 SERIES RECEIVER ....................................................................................................................................... 11
(6) SPECIFICATIONS ........................................................................................................................................... 12
(7) DRAWINGS .................................................................................................................................................. 13
(8) WARRANTY INFORMATION ......................................................................................................................... 13
(9) CONTACT INFORMATION ............................................................................................................................. 14
FT100 Series Installation & Operation Manual
www.ot-systems.com 4
(1) Safety Instructions
Please be familiar with all information in this manual prior to installation and operation.
Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following
safety precautions apply.
Warning: Do not disconnect the fiber optic connector while the unit is powered up. Exposure to Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up.
Caution: Any access to the controls, adjustments, or performing operations, which are other than those specified may result in hazardous radiation exposure. Permanent eye damage or other bodily injuries may be resulted from such exposure even for only seconds.
Note 2: This assembly contains parts sensitive to damage by electrostatic discharge (ESD). ESD precautionary procedures should be applied in the course of touching, removing or inserting parts or assemblies.
FT100 Series Installation & Operation Manual
www.ot-systems.com 5
(2) Product Overview
2.1 Introduction
The FT100 Series products comprise of either single-mode or multi-mode fiber optic transmitters and receivers for the optical transmission of ONE forward (Tx → Rx) video singal on one fiber. The products work at wavelengths of 1310nm or 1550nm with either a 9/125um or
62.5/125um fiber for single-mode or multi-mode transmission respectively.
A non-compressed 10-bit digital video transmission scheme is implemented which supports video in NTSC, PAL and SECAM formats. Time Division Multiplex (TDM) technology is employed for digital transmission of forward video.
For single-mode transmission, we also offer specifically designed products for long-haul transmissions up to 60km. These models include the letter “L” in the suffix, e.g. FT100-SSTL for Tx, FT100-SSRL for Rx, etc.
The FT100 Series units are available as standalone units, which can be mounted horizontally or vertically wall-mounted on any fixture. The standalone unit comes with an external power supply FT-PA/12V, which can be powered by local 110/220V power.
The FT100 Series units are also available as plug-in card modules installed in a 19” rack-mount chassis. Each plug-in card occupies one slot in the rack-mount chassis. The rack mount chassis has to be ordered separately, and comes with its own power supply for powering the installed card modules.
FT100 Series Installation & Operation Manual
www.ot-systems.com 6
2.2 Models selection table
Type
Mode
Models1
Descriptions
Installation
requirements
Remarks
Standalone Units
SIngle-Mode
FT100-SSTSA
Single-mode 1-Ch. Video Transmitter Standalone Unit
Horizontally or vertically wall-mounted Standalone unit
FT-PA/12V external power supply is included for the Standalone unit
2
FT100-SSTLSA
Single-mode Long-haul 1-Ch. Video Transmitter Standalone Unit
FT100-SSRSA
Single-mode 1-Ch. Video Receiver Standalone Unit
FT100-SSRLSA
Single-mode Long-haul 1-Ch. Video Receiver Standalone Unit
Multi-Mode
FT100-SMTSA
Multi-mode 1-Ch. Video Transmitter Standalone Unit
FT100-SMRSA
Multi-mode 1-Ch. Video Receiver Standalone Unit
Card Modules
Single-Mode
FT100-SST
Single-mode 1-Ch. Video Transmitter Card Module
Housed in FT-C18 chassis
3
FT-C18 chassis has to be ordered separately
FT100-SSTL
Single-mode Long-haul 1-Ch. Video Transmitter Card Module
FT100-SSR
Single-mode 1-Ch. Video Receiver Card Module
FT100-SSRL
Single-mode Long-haul 1-Ch. Video Receiver Card Module
Multi-Mode
FT100-SMT
Multi-mode 1-Ch. Video Transmitter Card Module
FT100-SMR
Multi-mode 1-Ch. Video Receiver Card Module
1
If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT100-FST
2
FT-PA/12V works under 100 -240VAC, 50/60Hz power supply
3
Refer to FT-C18 product manual for specifications
FT100 Series Installation & Operation Manual
www.ot-systems.com 7
(3) Installation
3.1 General
All OT Systems products are thoroughly inspected, tested and securely packaged before delivery to ensure a stable, intact and trouble-free service. Please check the equipment upon receipt for any visible damage which may have been caused during shipping.
The FT100 Series standalone units (Fig. 3.1) can be either horizontally or vertically wall-mounted, or mounted on any fixture. The Standalone unit works with an external power supply FT-PA/12V powered by local 110/220V power.
The FT100 Series card modules are housed inside the FT-C18 rack-mount chassis (Fig. 3.2) with an included power supply unit. The whole chassis is powered by local 110/220V power. FT-C18 is a standard 19” (483mm) rack-mount chassis which occupies 4 rack units (177.8mm) in height. Each FT100 card module occupies one slot space inside and a total of 18 cards can be housed inside the chassis.
3.2 Standalone unit installation
a) Mount the standalone unit onto a fixture, (either on the wall or on a flat surface) with four screws through the holes on the mounting frame to secure it in position. b) The provided power supply should also be mounted on the same fixture or in the proximity for connection of the supply cables to the unit, provided that an AC power supply socket is nearby for powering the adaptor. c) Connect all the signal inputs and outputs at the back of the unit with appropriate cables: fiber optic cable for optical link, BNC cable for video input/output (Tx/Rx). d) Once the unit is powered up, check that the red POWER LED on the unit is lit. If not, check the power supply cable connections between the unit and the power supply socket. e) With all the signals available at the input and output ports, check the status of LEDs located on the unit. With correct status of each LED, installation is now completed [for LEDs status, see Operational Guides on this manual’s section (5)].
Fig. 3.1 Standalone unit
Fig. 3.2 FT-C18 chassis
FT100 Series Installation & Operation Manual
www.ot-systems.com 8
3.3 Card module installation
a) Insert the card module into the FT-C18 chassis along the top and bottom card guides of an empty slot and push the card into the multi-pin socket at the rear firmly. Secure with the provided thumb screws. b) Repeat the above procedure for all the rest card modules. Unused slots must be covered with blank panels provided. c) Connect all the signal inputs and outputs at the back of the unit with appropriate cables: fiber optic cable for optical link, BNC cable for video input/output (Tx/Rx). d) Once the chassis is powered up, check that the red POWER LED on the front and back panels of the card modules are lit. If not, check the power supply cable connections between the chassis and the power supply socket. For failures of individual card’s POWER LEDs, check the corresponding card modules, whether they have been inserted properly. e) With all the signals available at the input and output ports, check the status of LEDs located on the unit. With correct status of each LED, installation is now completed [for LEDs status, see
Operational Guides on this manual’s section (5)].
(4) Cable Connections & Setup Procedures
4.1 System cable connections
Signal Type
Cable Type
Connector
Optical
Single-mode or Multi-mode fiber
ST (or FC) Connector
Video
Coaxial Video Cable
BNC Connector
Typical System Cable Connections Diagrams:
Standalone Transmitter Standalone Receiver
Fig 4.1 Standalone unit to Standalone unit connection diagram
FT100 Series Installation & Operation Manual
www.ot-systems.com 9
Standalone Transmitter Card Module Receiver
Fig 4.2 Standalone unit to Card Module connection diagram
Card Module Transmitter Card Module Receiver
Fig 4.3 Card Module to Card Module connection diagram
FT100 Series Installation & Operation Manual
www.ot-systems.com 10
4.2 Ground connection
For enhanced safety to reduce the risks of electrical shock and physical damage, caused by lightning and other power surges, as well as a connection to the surge suppresion devices in the product, a screw terminal is provided on the Standalone cabinets (Fig. 4.4). It is highly recommended that the Standalone unit have good ground connections to the buildings ground in accordance with the local codes.
Fig. 4.4 Standalone unit earth ground terminal location
FT100 Series Installation & Operation Manual
www.ot-systems.com 11
(5) Operational Guides
5.1 FT100 Series Transmitter
LED Indicators
Indicator
Color
Description
PWR
Red
Lit when power is supplied to the Transmitter.
OL
Yellow
Lit when optical signal from receiver to transmitter is active.*
VIDEO IN / VIN
Green
Lit when video signal is fed into the VIDEO IN connector.
* For products with uni-directional signal transmission, the OL LED on the Tx is not lit because optical signal from the Rx to the Tx is
always inactive.
Signal Ports
OPT -
ST (or FC) Optical Connector for fiber cable connection.
VIDEO IN -
BNC Video Connector for video signal input.
5.2 FT100 Series Receiver
LED Indicators
Indicator
Color
Description
PWR
Red
Lit when power is supplied to the Receiver.
OL
Yellow
Lit when optical signal from transmitter to receiver is active.
VIDEO OUT / VOUT
Green
Lit when video signal is received at VIDEO OUT connector.
Signal Ports
OPT -
ST (or FC) Optical Connector for fiber cable connection.
VIDEO OUT -
BNC Video Connector for video signal output.
FT100 Series Installation & Operation Manual
www.ot-systems.com 12
(6) Specifications
MODELS*
PARAMETERS
FT100-SST(R)SA FT100-SST(R) (Single-Mode)
FT100-SST(R)LSA FT100-SST(R)L (Single-Mode)
FT100-SMT(R)SA FT100-SMT(R) (Multi-Mode)
OPTICAL
No. of Fiber / Connector
1 / ST (or FC)
1 / ST (or FC)
1 / ST (or FC)
Wavelength
1310 nm
1550 nm
1310 nm
Optical Power Budget
17 dB
24 dB
23 dB
Max Distance
40 km
60 km
4 km
ELECTRICAL VIDEO
Channel / Connector
1 / BNC
System
PAL, NTSC, SECAM
Bandwidth
6.0 MHz
Input/Output Impedance
75 Ohm
Input/Output Level
1.0 Vp-p typical
Differential Gain
< 1% typical
Differential Phase
< 1o typical
SNR
> 65dB
POWER
Power consumption
12VDC @ 3W
Power Supply
Standalone Unit: FT/PA12V DC Adaptor
Card module: Powered by FT-C18 chassis
Connector (Standalone unit)
2-pin Screw Terminal
PHYSICAL
Weight
Standalone unit: 0.56 kg Card module: 0.16 kg
Dimensions (W x H x D)
Standalone unit: 156 x 30.5 x 223 mm (MAX)
Card module: 148 x 20.4 x 213 mm (MAX)
ENVIRONMENTAL
Operating Temperature
-40oC ~ +75oC
Storage Temperature
-40oC ~ +85oC
Relative Humidity
0 ~ 95% non-condensing
MTBF
>100’000 Hours
*If the optical connector is FC type, the suffix in the model number will be “-FXX”. Eg. FT100-FST
FT100 Series Installation & Operation Manual
www.ot-systems.com 13
(7) Drawings
Fig. 7.1 Dimensional drawings of Standalone unit (mm)
(8) Warranty Information
All OT Systems FT Series products are subject to a limited life-time warranty offered by the company in normal circumstances. Please refer to the OT Systems Products Warranty Statement for details. Access to the statement is available in our company website at
www.ot-systems.com.
FT100 Series Installation & Operation Manual
www.ot-systems.com 14
(9) Contact Information
APAC Operation
Address: Unit 1023, 10/F, Landmark North, 39 Lung Sum Avenue, Sheung Shui, N.T., Hong Kong Tel: (852) 2672 5153 Fax: (852) 2679 0756 Sales Inquiries
sales@ot-systems.com
Technical Support
techsupport@ot-systems.com
EMEA Operation
Address: J. Slovackio str. 4, LT-11107, Vilnius, Lithuania
Tel: (370) 60730087 Fax: (370) 52051855 Sales Inquiries
sales@ot-systems.com
Technical Support
techsupport@ot-systems.com
AMERICAS Operation
Address: 18 West Main Street, Plano, IL 60545, U.S.A.
Tel: (1) 630 554 9178 Fax: (1) 630 554 9179 Sales Inquiries
sales.usa@ot-systems.com
Technical Support
techsupport.usa@ot-systems.com
Loading...