OSRAM and Logo are registered trademarks of OSRAM
© 2013 O SRA M SYL VAN IA 0 1
www.sylvania.com/encelium
Installation Notes
The Phase Cut Dimming Modules are to be installed in
dry,
indoor locations ONLY.
Troubleshooting
There are no user-serviceable parts inside of the Ph
ase Cut
Dimming Module. Please return the device to OSRAM
Sylvania Inc if service is required.
Regulatory Approvals
ote: This equipment has been tested and found to comply
N
with the limits for part 18 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct
the interference at his own expense.
Modifications not expressly approved by the manufacturer could
void the user's authority to operate the equipment under FCC
rules.
The contents of this Wiring and Installation Manual
are subject
to change without notice.
United States
OSRAM SYLVANIA
100 Endicott Street
Danvers, MA 01923
1-800-LIGHTBULB
Trade
Phone: 800-255-5042
Fax: 800-255-5043
National Accounts
Phone: 800-562-4671
Fax: 800-562-4674
OEM/Special Markets
Phone: 800-762-7191
Fax: 800-762-7192
Retail
Phone: 800-842-7010
Fax: 800-842-7011
SYLVANIA Lighting Services
Phone: 800-323-0572
Fax: 800-537-0784
Display/Optic
Phone: 888-677-2627
Fax: 855-543-1043
Canada
OSRAM SYLVANIA LTD.
2001 Drew Road
Mississauga, ON L5S 1S4
1-800-LIGHTBULB
Trade
Phone: 800-263-2852
Fax: 800-667-6772
OEM/Special Markets/Display/Optic
Phone: 800-265-2852
Fax: 800-667-6772
Retail
Phone: 800-720-2852
Fax: 800-667-6772
SYLVANIA Lighting Services
Phone: 800-663-4268
Fax: 866-239-1278
Mexico
OSRAM MEXICO
Tultitlan/Edo de Mexico
Phone: 011-52-55-58-99-18-50
ENCELIUM® Products
United States
Phone: 201-508-1570
Fax: 201-508-1589
Canada
Phone: 905-731-7678
Fax: 905-731-1401
www.sylvania.com
/Sylvania
/sylvania
™
ENCELIUM
Energy Management System
Phase Cut Dimming Module
Wiring and Installation Manual
The Phase Cut Dimming Module (PCDM) provides an
i
nterface between the Phase Cut dimmable (forward
and reverse phase) ballasts/LED drivers and the
ENCELIUM GreenBus II™ communication network.
The PCDM is automatically addressed as soon as it is
connected to an Energy Control Unit (ECU).
Individually addressable, the PCDM enables each
group or zone of fixtures to be independently
controlled and configured to best meet the needs of
the facility.
The PCDM is designed to control popular load types
such as Incandescent/Halogen lamps, Fluorescent
ballasts, LED fixtures, and LED/CF lamps. The phase
cut dimmable fixtures connected to a PCDM can then be controlled by any of the Encelium low voltage
wall station controllers, the Touch Screen panel or from Polaris 3D™ software through the GreenBus
II™ communication network. PCDM has a built-in relay which provides ON/OFF switching control in
addition to smoothly dimming the fixtures.
The following model is available:
ndoor Locations:
I
EN-PCDM-GB2
When using electrical equipment, basic safety precau
tions should always be followed
including the following:
• READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
• Do not let power supply cords touch hot surfaces.
• Do not mount near gas or electric heaters.
• Equipment should be mounted in locations and at heights where it will not readily be subjected to
tampering by unauthorized personnel.
• The use of accessory equipment is not recommended by OSRAM Sylvania as it may cause an
unsafe condition.
• Do not use this equipment for other than the intended use.
SAVE THESE INSTRUCTIONS
ENCELIUM and Polaris 3D are registered trademarks of OSRAM SYLVANIA, Inc
GreenBus II are trademarks of OSRAM SYLVANIA, Inc.
SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA, Inc.
OSRAM and Logo are registered trademarks of OSRAM
GreenBus II™ Wiring
Communication Circuit (24VDC, Class 2)
reenBus IITM is a low-cost, high reliability communication means to report sensor information back to
G
the ENCELIUM Energy Management System and to obtain optimum brightness settings for each
individual light fixture from the system – optimized to result in minimum energy costs for any given
building.
The GreenBus II
TM
wiring originates at an Energy Control Unit (ECU) and propagates in a daisy-chain or
“T” fashion from module to module (or other compatible equipment).
GreenBus II
GreenBus II
TM
uses proprietary connectors and jacks for ease of installation only.
TM
is a proprietary standard. Connect to ENCELIUM Energy Management System
only. Do not connect to other circuits.
Black – Line in
W
Earth Ground
hite – Neutral
Red – Relay output & Dim Control (connect to load)
Relay Contact; recommended relay
switching capacity 120VAC, 450W or
277VAC, 900W maximum
GreenBus II TM Communication
(Communication Circuit, Low Voltage)
Connect to ENCELIUM Energy Management System only. Do not connect to other circuits.
Maximum 100 total devices
GreenBus II
TM
must be laid out as per ENCELIUM EMS supplied drawing. If changes are required,
determine an optimum wiring path utilizing the supplied prefabricated cables, based on the position of
light fixtures and sensors. As the modules obtain power via the GreenBus IITM, the number of modules
on each chain is limited. It is suggested to leave room for future system upgrades and to limit the
number of modules per chain to 100 units during initial installation.
In a typical installation, Phase Cut Dimming Modules connect to Incandescent/Halogen lamps,
Fluorescent ballasts, LED fixtures, and LED/CF lamps that are capable of being dimmed via phase cut
method (forward and reverse phase).
The Phase Cut Dimming Module is typically connected to an individual or group of fixtures/lamps.
The mechanical construction allows for simple installation of the Phase Cut Dimming Module on top of a
standard square 4 11/16” junction box. Only a 4 11/16” junction box can be used, as the mounting
holes on the Phase Cut Dimming Module properly align with the holes on the junction box. ENCELIUM
GreenBus II™ communication wiring is still accessible from the outside of the junction box, while all
necessary wiring to the load (single or multiple ballasts/ LED fixtures) is done on the inside.
Wire as shown. Refer to local code, etc.
Refer to local code, etc.
Refer to local code, etc.Refer to local code, etc.
Absolute maximum load ratings
120VAC: 450W, 3.8A max
277VAC: 900W, 3.3A max
Due to the internal relay, power feed to module may be live even if lights are off. Turn off
power at circuit breaker or fuse before installing or servicing module. Observe lockout
procedures.
ENCELIUM and Polaris 3D are registered trademarks of OSRAM SYLVANIA, Inc
GreenBus II are trademarks of OSRAM SYLVANIA, Inc.
SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA, Inc.