Osram OT EASY 32 CC Fitting Instructions Manual

Page 1
OSRAM GmbH
Kunden Service Center Customer-Service-Center (CSC)
Steinerne Furt 62 86167 Augsburg Germany
Tel : +49 (0) 1803 677 - 200 (kostenpichtig / charges apply) Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de
40083215470880
4008321547088
Page 1 of 3
LED control unit Fitting instructions
I 2010
OT_EASY_32_CC_ma1001en_we1.01.indd
OT EASY 32 CC
110
CH4 CH3 CH2 CH1
SEC 350 mA/Ch.
SELV-
equiv.
EASY
signal
120-
240V
50/60Hz
PRI
DONOT
USE
tc= 75°C max
N
a
SELV-
equiv.
Colorand WhiteLED connections
COLOROUTPUT WHITE CH1 CH2 CH3 CH4
R G B W
Warm
Warm
Cold Cold
A64058A0072
Made in Italy byOSRAM
A
C
B
D
110
CH4 CH3 CH2 CH1
SEC350 mA/Ch.
SELV-
equiv.
EASY
signal
120-
240V
50/60Hz
PRI
DONOT
USE
tc= 75°Cmax
N
a
SELV-
equiv.
Colorand White LED connect ions
COLOROUTPUT WHITE CH1 CH2 CH3 CH4
R G B W
Warm
Warm
Cold Cold
A64058A0072
Madein Italy by OSRAM
-
+
PWM
350mA LED
-
+
-
+
E.g. Red or Warm White
E.g. Green or Warm White
E.g. Blue or Cold White
E.g. White or Cold White
-
+
4
max.
100 m
G
H
H
J
H
K
PE N L
E
F
Description
Purpose and application
The OT EASY 32 CC LED control unit can be used to imple­ment static and dynamic lighting concepts for RGB, RGB+W and tunable white LED applications.
Installation
Safety instructions
The control unit must only be installed and put into operation by a qualied electrician. The applicable safety regulations and accident prevention regulations must be observed.
WARNING!
Exposed, live cables or damaged housing.
Danger of electric shock!
• Only work on the control unit when it is de­energised.
CAUTION!
Destruction of the control unit and other devices through incorrect mounting!
• Ensure that the external pushbutton is designed for the mains voltage.
• Do not wire the control and pushbutton lines with an external voltage, especially not a mains voltage of 120-240 V.
• Do not exceed the maximum number of connect­able components.
• Only use the intended infrared receiver types.
Wiring diagram
E Power switch and/or timer switch for mains voltage (optional)
F External pushbutton
G Infrared receiver (or other component)
H Y-connector
J Pushbutton coupler (or other component)
K EASY PC Kit (or other component)
Function and operation
The four pulse-width modulated (PWM) 350 mA constant current channels can be individually controlled. See for the OT EASY 60 II LED control unit instruction sheet for a complete function and operation description (www.osram.com/ecg-lms). OT EASY 32 CC is supported by the EASY Color Control software, version 1.4 or higher. Software updates are available at http://www.osram.com/ecg-software.
Connections
The control unit has the following connections:
• Mains connection (A)
• Input for EASY signal (B)
• Input for external pushbutton (C)
• Outputs for connecting LED modules (D)
Page 2
Page 2 of 3
Installation (cont.)
8,5-9,5 mm
16 mm
8,5-9,5 mm
16 mm
8,5-9,5 mm
M
N
O
P
CH4 CH3 CH2 CH1
SEC 350 mA/Ch
.
SELV-
equiv.
EASY
signal
120-
240 V
50/60 Hz
PR I
DO NOT
USE
SELV-
equiv.
L
Connecting the control unit
Notes
• Max. line length to LED modules: 10 m
• Line cross-sections and cable diameters/sizes:
Connection Line cross-
section
Cable diameter/ size
Power supply 0.5 – 1.5 mm² 7 – 11 mm
External pushbutton
0.2 – 0.5 mm² 3.2 x 5.2 mm
EASY signal 2.2 x 4.7 mm
LED modules 0.5 – 1.5 mm² 7 – 11 mm
• Only use LED series circuits at every LED output.
• Only use LED modules/xtures with separated anodes and cathodes.
• The maximum number of LEDs that can be connected in se­ries to each output channel is limited by the forward voltage V
f
of the individual LEDs, the control unit output voltage and the cable voltage drop (e.g. Vf = 3,5 V à max. 6 LEDs). De­tails on the limitations can be found in the OPTOTRONIC® technical instructions.
• A different number of LEDs per channel (not more than the max. number each) is allowed. Automatic load detection is performed at power-on.
• To be able to use the colour/colour temperature algorithm of EASY Color Drive and EASY Hybrid Remote, channels and LED types are assigned as follows:
Channel RGB+W WW / CW
(Tunable White)
CH1 Red Warm white
CH2 Green Warm white
CH3 Blue Cold white
CH4 White/amber Cold white
• In combination with other types of EASY control units, 4-channel tunable white congurations require to set one OT EASY 32 CC as master.
• Master-slave connection: Max. 1 master and 15 slaves con­nectable, see “Connecting the inputs”.
Connecting the inputs
Connect the 4p4c modular connector (N) of the EASY signal
line.
Strip the power cable (M), remove the insulation from the
phase and neutral conductors and connect to the terminals.
Connect the line of the external pushbutton to the terminals,
if applicable, or insert the short circuit bridge (O) for slave mode. Lead external push-button cable and EASY signal ca­ble together (overlapped) through one opening (L) to ensure a correct cable clamping function.
Use cable clamps.
Insulate the cable PE conductor, if necessary.
Connecting the outputs
Strip the 4-wire lines (P), remove the insulation and connect
to the terminals. Do not connect the terminals labeled “DO NOT USE”.
Use cable clamps.
Page 3
Page 3 of 3
32 mm
223 mm
96 mm
215 mm
207 mm
Appendix
Technical data
Compatible LED mod­ules/xtures
(Only current controlled LED modules/xtures with LEDs in series circuits)
With respect to the output condi­tions:
350 mA LED (for instance Golden DRAGON
®
Plus, DRAGON® X, etc.)
Series of 350 mA LED (for instance DRAGONtape
®
, DRAGONpuck®,
DRAGONeye®, etc.)
Operating voltage 120-240 V
AC
/50-60 Hz
Permissible voltage range
108-264 V
AC
Line current typical 200 mA @ 230 V/50 Hz
Output voltage 1.8 ... 24 V (typical ≥ 21,5 V)
Output current 350 mA per channel
Max. output wattage 32 W, max. 8 W per channel
Power factor PF 0.9 C at full load
Max. input power 40 W at 230 V
Control signal Digital EASY signal via 4-pin RJ-11
modular connection (4p4c)
Master-slave connection
Max. 100 m total line length Max. 50 m to pushbutton coupler Max. 1 master and 15 slaves are
connectable, extension up to 64 with EASY SYS CP
Do not route the master-slave con­nections together with the power supply or LED lines
Max. number of connectable com­ponents
• 4 EASY IR sensors
• 1 EASY pushbutton coupler
• 1 EASY USB adapter
• 1 EASY RC
Dimming mode PWM (linear / logarithmic), selecta-
ble by EASY PC Kit, 16 bit resolution
Dimming range 1-100%
Operating temperature -20 °C … +50 °C
EASY interface 4-pin modular connection
Secondary side Plug-in terminals
Max. secondary line length
10 m
Dimensions (L x W x H)
223 x 96 x 32 mm
Applicable standards
Safety EN 61347
Performance EN 62384
Radio interference EN 55015
Harmonic content EN 61000-3-2
Immunity EN 61547
Conformity with the relevant EU directives is conrmed by the CE symbol.
Loading...