1. Technical Data
Nominal Voltage 220 – 240 Vac Output Voltage 18 – 36Vdc Input Voltage 198 – 264 Vac Maximum Output Voltage 50Vdc Line Current, nominal 120mA @ 230 Vac Nominal Output Current 500mA DC +/- 10% Mains Frequency 50 / 60 Hz Typ.dimming range* 10 - 100% Power Factor 0.95 @ 23 0 Vac Ambient Temperature -20°C to +55°C Maximum Output Power P IP Rating IP 20 Max. Output Cable Length 2m
* Suitable for use with electronic leading and trailing edge dimmer
2.
Connection Schemes
2.1 LED modules in series:
2.2 Parallel connection on the secondary side is not allowed
OTe 18/220-240/500 PC
2
220-240VAC
OTe 18/220-240/500 PC
2
OTe 18/220-240/500 PC
2
220-240V
AC
OTe 18/220-240/500 PC
2
OTe 18/220-240/500 PC
2
OTe 18/220-240/500 PC
2
Common Cathode
The installation of two or more OPTOTRONIC OTe 18/220-240/500 PC Power Supplies with common
“-“ or “+” wiring by the intention to save wire to LED modules is prohibited, in order to avoid exceeding the maximum allowed system touch current levels on the accessible parts of the installation.
18 W Max. Case Temperature at tc +75°C
max
220 - 240V
prohibited
C
OTe 18/220-240/500 PC
2
LED modules should be connected in series.
+
LED-Module
500mA , 9W-18W
-
+
LED-Module
500mA , 9W-18W
-
+
LED-Module
500mA , 9W-18W
-
+
-
+
-
to LED
to LED
220-240V
220-240V
+
-
to LED
Common Anode
+
LED Module
-
OTe 18/220-240/500 PC
2
AC
OTe 18/220-240/500 PC
2
OTe 18/220-240/500 PC
2
AC
OTe 18/220-240/500 PC
2
OTe 18/220-240/500 PC
2
OTe 18/220-240/500 PC
2
+
-
+
-
+
-
prohibited
+
-
+
-
LED-Module 500mA, 54W
+
-
to LED
to LED
to LED
OSRAM AG
www.osram.com
Steinerne Furt 62, 86167 Augsburg, Germany
No. 1, North Industrial Road
528000 Foshan Guangdong, P.R. China
OPTOTRONIC® OTe 18/220-240/500 PC
500mA Constant Current LED Power Supply with Phase Cut functionality
3.
Wire and Connection
Ensure that the LED module load is within the range of rated voltage, current and power supply (see
Technical data)
The luminaries’ manufacturer is responsible for providing the required clearance and creepage distances
and also for the protection against electrical shock, especially for the line and load wires.
Wiring Preparation:
4. Earth Connection
OTe 18/220-240/500 PC is a “Protection Class II” power supply, therefore ground connection is not
required
5. Mounting and Environmental protection
The control gear is a built in type for luminaire integration; an optional cable clamp is available for
independent installation; proper cables should be used.
Maximum permissible ambient temperature must not be exceeded. Make sure there is adequate space to
avoid heat build-up. In critical installations, the temperature at tc point should not exceed the declared value.
6.
General note
Power supplies must be installed by qualified electrician  Disconnected from mains supply before wiring work  Hot plug-in or secondary switching of LEDs is not permitted, as it may cause a very high transient current
to the LEDs
For further information, please refer to “OPTOTRONIC -Technical guide” at www.osram.com
Proper and safety usage and installation of the product shall comply with product datasheet and OPTOTRONIC Technical guide. The latest documents are available at www.osram.com