• Besonderheit des Bauteils: fokussierte
Abstrahlung in SMT-Technologie; hohe
Helligkeit in Achsrichtung; höhere
Umgebungstemperatur bei gleichem Strom im
Vergleich zur TOPLED
• Wellenlänge: 469 nm (blau), 503 nm (verde),
525
nm (true green)
• Abstrahlwinkel: 20°
• Technologie: InGaN
• optischer Wirkungsgrad: 3 lm/W (blau),
10
lm/W (verde), 13 lm/W (true green)
• Gruppierungsparameter: Lichtstärke,
Wellenlänge
• Verarbeitungsmethode: für alle
SMT-Bestücktechniken geeignet
• Lötmethode: IR Reflow Löten und
Wellenlöten
• Vorbehandlung: nach JEDEC Level 2
• Gurtung: 12-mm Gurt mit 2000/Rolle,
ø330
• ESD-Festigkeit: ESD-sicher bis 2 kV nach
JESD22-A114-B
• package: white P-LCC-4 package, colorless
clear resin
• feature of the device: focussed radiation in
SMT technology; high brightness in beam
direction; higher ambient temperature at the
same current possible compared to TOPLED
Anm.: Die Gruppierung der LEDs in [lux] erfolgt mit der innovativen Partial Flux-Methode. An Bauteilen wurden
Vergleichsmessungen jeweils mit dem "Partial Flux"-Testkopf und dem "Standard LED"-Testkopf (gemäß CIE-127-B)
durchgeführt. Ziel dieses Vergleichs ist ein besseres Verständnis des Lichtflusses in [lux] in Relation zu den
Lichtstärkewerten in [cd]. Der Vergleich stellt keine eins-zu-eins Korrelation dar. Das Verhältnis von typischen Werten,
die mit dem "Partial Flux”-Testkopf gemessen werden, zu den mit dem “Standard LED”-Messkopf gemessenen ist [lux]
x 0.61 =[cd].
Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen
Helligkeitsgruppen (siehe
geliefert. Z.B.: LB E63C-T2V1-35 bedeutet, dass auf dem Gurt nur eine der Helligkeitsgruppen T2, U1, U2 oder V1
enthalten ist.
Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden.
Gleiches gilt für die Farben, bei denen Wellenlängengruppen gemessen und gruppiert werden. Pro Gurt wird nur eine
Wellenlängengruppe geliefert. Z.B.: LB
-3, -4, oder -5 enthalten ist (siehe
Um die Liefersicherheit zu gewährleisten, können einzelne Wellenlängengruppen nicht bestellt werden.
Note: The innovative partial flux method is applied to the grouping of LEDs in [lux]. Measurements were made in order to
compare the results of the "Partial Flux" testhead to the "standard LED" testhead (in compliance with CIE-127-B). The
comparison should be used for a better understanding of partial flux in [lux], in relation to the values stated in luminous
intensity [cd]. This should not be understood to be a one-to-one correlation. The ratio of typical values measured with
the "Partial Flux" testhead and the normal LED testhead is[lux]
The above Type Numbers represent the order groups which include only a few brightness groups (see page 5 for
explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g.
LB
E63C-T2V1-35 means that only one group T2, U1, U2 or V1 will be shippable for any one reel.
In order to ensure availability, single brightness groups will not be orderable.
In a similar manner for colors where wavelength groups are measured and binned, single wavelength groups will b e
shipped on any one reel. E.g. LB
In order to ensure availability, single wavelength groups will not be orderable (see
Emissionsfarbe
Color of
Emission
Partieller
Lichtfluss
Partial Flux
I
= 30 mA
F
E
[lux]
V
blue355 ... 900
560 ... 1120
355 ... 1120
verde1400 ... 3550
2240 ... 5600
1400 ... 5600
true green1800 ... 4500
2800 ... 7100
1800 ... 7100
Seite 5 für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Gurt
E63C-T2V1-35 bedeutet, dass auf dem Gurt nur eine der Wellenlängengruppen
Seite 5 für nähere Information).
E63C-T2V1-35 means that only 1 wavelength group -3, -4, oder -5 will be shippable.
Gruppenbezeichnung auf Etikett
Group Name on Label
Beispiel: AB-3
Example: AB-3
Helligkeitsgruppe
Brightness Group
Wellenlänge
Wavelength
AB3
Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
Note: No packing unit / tape ever contains more than one group for each selection .
2006-04-135
Prinzipieller Messaufbau für Partial Flux Messung
Schematic test method for partial flux measurement
Referenzebene des Detektors (ø14 mm)
Reference layer of detector (ø14 mm)
LB E63C, LV E63C, LT E63C
= 40˚θ
d
OHAY0907
2006-04-136